{"title":"当暴露于大振荡剪切应力振幅时,实验室大鼠血栓失去三分之一的刚度:与人类凝块的对比行为","authors":"U. Windberger, V. Glanz, L. Ploszczanski","doi":"10.3390/ijtm2030026","DOIUrl":null,"url":null,"abstract":"Rats impress by their high platelet count resulting in hypercoagulability, which protects the animals from severe bleeding. However, platelets also import numerous stiff junction points into the fibrous system of a clot, also enhancing the pre-stress of the fibrin fibers, which lowers their deformability. Clot deformation is clinically important since large strains are present in the arterial tree (caused by the propagation of pressure and pulse waves), and a clot is considered “safe” when it can deform over a long range of strain amplitudes. We tested clot formation and the behavior of fully formed blood clots of laboratory rats at large sinusoidal shear stress amplitudes by rheometry and compared outcomes to human reference data. We found that fiber density (by scanning electron microscopy) and clot stiffness was pronounced compared to humans and differed with sexual dimorphism and with rat strain. Using our large amplitude oscillation (LAOS) protocol, we detected that rat clots yielded with a frustrated attempt to stiffen instead of showing the macroscopic stiffening response that is typical for human clots. We attribute this behavior to the appearance of multiple microfractures until, finally, a few leading fibers uptake the load. Rat clots also failed to align fibers in shear direction to initiate affine deformation. The rat clot phenotype differs substantially from the human one, which must be considered in research and toxicological testing. If microfractures in the fiber meshwork are concentrated in vivo, parts of a clot may break off and be washed away. However, homogenously distributed microfractures may open pores and allow the penetration of plasminogen activators. What occurs in the rat vasculature depends on the on-site clot composition.","PeriodicalId":43005,"journal":{"name":"Journal of International Translational Medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Laboratory Rat Thrombi Lose One-Third of Their Stiffness When Exposed to Large Oscillating Shear Stress Amplitudes: Contrasting Behavior to Human Clots\",\"authors\":\"U. Windberger, V. Glanz, L. Ploszczanski\",\"doi\":\"10.3390/ijtm2030026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Rats impress by their high platelet count resulting in hypercoagulability, which protects the animals from severe bleeding. However, platelets also import numerous stiff junction points into the fibrous system of a clot, also enhancing the pre-stress of the fibrin fibers, which lowers their deformability. Clot deformation is clinically important since large strains are present in the arterial tree (caused by the propagation of pressure and pulse waves), and a clot is considered “safe” when it can deform over a long range of strain amplitudes. We tested clot formation and the behavior of fully formed blood clots of laboratory rats at large sinusoidal shear stress amplitudes by rheometry and compared outcomes to human reference data. We found that fiber density (by scanning electron microscopy) and clot stiffness was pronounced compared to humans and differed with sexual dimorphism and with rat strain. Using our large amplitude oscillation (LAOS) protocol, we detected that rat clots yielded with a frustrated attempt to stiffen instead of showing the macroscopic stiffening response that is typical for human clots. We attribute this behavior to the appearance of multiple microfractures until, finally, a few leading fibers uptake the load. Rat clots also failed to align fibers in shear direction to initiate affine deformation. The rat clot phenotype differs substantially from the human one, which must be considered in research and toxicological testing. If microfractures in the fiber meshwork are concentrated in vivo, parts of a clot may break off and be washed away. However, homogenously distributed microfractures may open pores and allow the penetration of plasminogen activators. What occurs in the rat vasculature depends on the on-site clot composition.\",\"PeriodicalId\":43005,\"journal\":{\"name\":\"Journal of International Translational Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of International Translational Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/ijtm2030026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of International Translational Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/ijtm2030026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Laboratory Rat Thrombi Lose One-Third of Their Stiffness When Exposed to Large Oscillating Shear Stress Amplitudes: Contrasting Behavior to Human Clots
Rats impress by their high platelet count resulting in hypercoagulability, which protects the animals from severe bleeding. However, platelets also import numerous stiff junction points into the fibrous system of a clot, also enhancing the pre-stress of the fibrin fibers, which lowers their deformability. Clot deformation is clinically important since large strains are present in the arterial tree (caused by the propagation of pressure and pulse waves), and a clot is considered “safe” when it can deform over a long range of strain amplitudes. We tested clot formation and the behavior of fully formed blood clots of laboratory rats at large sinusoidal shear stress amplitudes by rheometry and compared outcomes to human reference data. We found that fiber density (by scanning electron microscopy) and clot stiffness was pronounced compared to humans and differed with sexual dimorphism and with rat strain. Using our large amplitude oscillation (LAOS) protocol, we detected that rat clots yielded with a frustrated attempt to stiffen instead of showing the macroscopic stiffening response that is typical for human clots. We attribute this behavior to the appearance of multiple microfractures until, finally, a few leading fibers uptake the load. Rat clots also failed to align fibers in shear direction to initiate affine deformation. The rat clot phenotype differs substantially from the human one, which must be considered in research and toxicological testing. If microfractures in the fiber meshwork are concentrated in vivo, parts of a clot may break off and be washed away. However, homogenously distributed microfractures may open pores and allow the penetration of plasminogen activators. What occurs in the rat vasculature depends on the on-site clot composition.
期刊介绍:
Journal of International Translational Medicine (JITM, ISSN 2227-6394), founded in 2012, is an English academic journal published by Journal of International Translational Medicine Co., Ltd and sponsored by International Fderation of Translational Medicine. JITM is an open access journal freely serving to submit, review, publish, read and download full text and quote. JITM is a quarterly publication with the first issue published in March, 2013, and all articles published in English are compiled and edited by professional graphic designers according to the international compiling and editing standard. All members of the JITM Editorial Board are the famous international specialists in the field of translational medicine who come from twenty different countries and areas such as USA, Britain, France, Germany and so on.