顶空气相色谱-火焰电离检测技术测定23种不同包衣片剂中有机挥发性杂质

Abida Latif, Humera Shafi Makhdoom, Muhammad Imran, M. Mazhar, E. Anwar, M. Sarwar, M. Tahir
{"title":"顶空气相色谱-火焰电离检测技术测定23种不同包衣片剂中有机挥发性杂质","authors":"Abida Latif, Humera Shafi Makhdoom, Muhammad Imran, M. Mazhar, E. Anwar, M. Sarwar, M. Tahir","doi":"10.4172/2153-2435.1000553","DOIUrl":null,"url":null,"abstract":"Organic solvents are extensively used in manufacturing processes of pharmaceutical formulations that cannot be completely eliminated from the product due to physical and chemical barriers. These solvents have no therapeutic value and may be toxic to human body if intake exceeds the permitted daily exposure. Therefore, a simple and sensitive method for simultaneous determination of methanol, acetonitrile, methylene chloride, n-hexane, cyclohexane, xylene, chloroform, nitromethane, toluene and pyridine was developed and validated. Separation was achieved on HP-Innowax polyethylene glycol gas chromatographic column (30 m × 250 μm × 0.25 μm) using Agilent 7890B gas chromatograph equipped with Agilent 7697A headspace auto-sampler and flame ionization detector. Twenty-three marketed coated tablet formulations (containing diclofenac sodium, Loratadine or montelukast sodium as active ingredient) were tested for the presence of volatile organic impurities using this method. Excellent results were obtained, within the globally accepted validation reference values, particularly taking into account the low concentration levels were investigated in twenty-three coated tablet formulations.","PeriodicalId":19833,"journal":{"name":"Pharmaceutica Analytica Acta","volume":"21 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Determination of Organic Volatile Impurities in Twenty-Three DifferentCoated Tablet Formulations Using Headspace Gas Chromatography withFlame Ionization Detection Technique\",\"authors\":\"Abida Latif, Humera Shafi Makhdoom, Muhammad Imran, M. Mazhar, E. Anwar, M. Sarwar, M. Tahir\",\"doi\":\"10.4172/2153-2435.1000553\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Organic solvents are extensively used in manufacturing processes of pharmaceutical formulations that cannot be completely eliminated from the product due to physical and chemical barriers. These solvents have no therapeutic value and may be toxic to human body if intake exceeds the permitted daily exposure. Therefore, a simple and sensitive method for simultaneous determination of methanol, acetonitrile, methylene chloride, n-hexane, cyclohexane, xylene, chloroform, nitromethane, toluene and pyridine was developed and validated. Separation was achieved on HP-Innowax polyethylene glycol gas chromatographic column (30 m × 250 μm × 0.25 μm) using Agilent 7890B gas chromatograph equipped with Agilent 7697A headspace auto-sampler and flame ionization detector. Twenty-three marketed coated tablet formulations (containing diclofenac sodium, Loratadine or montelukast sodium as active ingredient) were tested for the presence of volatile organic impurities using this method. Excellent results were obtained, within the globally accepted validation reference values, particularly taking into account the low concentration levels were investigated in twenty-three coated tablet formulations.\",\"PeriodicalId\":19833,\"journal\":{\"name\":\"Pharmaceutica Analytica Acta\",\"volume\":\"21 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutica Analytica Acta\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2153-2435.1000553\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutica Analytica Acta","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2153-2435.1000553","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

有机溶剂广泛应用于由于物理和化学障碍而不能从产品中完全消除的药物配方的制造过程中。这些溶剂没有治疗价值,如果摄入量超过允许的每日暴露量,可能对人体有毒。因此,建立了一种简便、灵敏的同时测定甲醇、乙腈、二氯甲烷、正己烷、环己烷、二甲苯、氯仿、硝基甲烷、甲苯和吡啶的方法,并进行了验证。色谱柱为HP-Innowax聚乙二醇气相色谱柱(30 m × 250 μm × 0.25 μm),色谱柱为Agilent 7890B气相色谱仪,配备Agilent 7697A顶空自动进样器和火焰电离检测器。23种已上市的包衣片剂配方(含有双氯芬酸钠、氯雷他定或孟鲁司特钠作为活性成分)使用该方法检测了挥发性有机杂质的存在。在全球公认的验证参考值范围内获得了极好的结果,特别是考虑到23种包衣片制剂的低浓度水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of Organic Volatile Impurities in Twenty-Three DifferentCoated Tablet Formulations Using Headspace Gas Chromatography withFlame Ionization Detection Technique
Organic solvents are extensively used in manufacturing processes of pharmaceutical formulations that cannot be completely eliminated from the product due to physical and chemical barriers. These solvents have no therapeutic value and may be toxic to human body if intake exceeds the permitted daily exposure. Therefore, a simple and sensitive method for simultaneous determination of methanol, acetonitrile, methylene chloride, n-hexane, cyclohexane, xylene, chloroform, nitromethane, toluene and pyridine was developed and validated. Separation was achieved on HP-Innowax polyethylene glycol gas chromatographic column (30 m × 250 μm × 0.25 μm) using Agilent 7890B gas chromatograph equipped with Agilent 7697A headspace auto-sampler and flame ionization detector. Twenty-three marketed coated tablet formulations (containing diclofenac sodium, Loratadine or montelukast sodium as active ingredient) were tested for the presence of volatile organic impurities using this method. Excellent results were obtained, within the globally accepted validation reference values, particularly taking into account the low concentration levels were investigated in twenty-three coated tablet formulations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Solubility Enhancement of Ritonavir: Co-Crystallization Development and validation of UV Spectrophotometric method for simultaneous equation of Aspirin and Omeprazole in tablet dosage form An Archive of 11 years in Pharmaceutical Science Development and Evaluation of Curcumin Floating Tablets Vital Registration in Medication Delivery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1