定量超声后向散射显微镜评价角膜假体原位生物整合

A. Saied, B. Dehecq, M. Savoldelli, B. Briat, J. Legeais, G. Berger
{"title":"定量超声后向散射显微镜评价角膜假体原位生物整合","authors":"A. Saied, B. Dehecq, M. Savoldelli, B. Briat, J. Legeais, G. Berger","doi":"10.1109/ULTSYM.1997.661770","DOIUrl":null,"url":null,"abstract":"In a previous preliminary study the authors have shown that 50 MHz ultrasound microscope coupled with the spectral analysis of radio frequency signal enable the imaging and evaluation of the biointegration of polymer implants used as support of keratoprosthesis (artificial cornea). In particular, the authors have demonstrated that the level of apparent backscatter was sensitive to the change in the polymer pore content (fluid or cells). In the current study, a larger number of polymer implants (n=21) at different colonization stages were explored in vitro and the authors investigated the potential of the frequency variation of both ultrasonic backscatter and attenuation coefficients to control and assess in situ the progressive biocolonization of the material. Quantitative echographic findings were correlated to histologic data which established the cell density in each specimen.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":"33 1","pages":"1093-1096 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of keratoprosthesis biointegration in situ with quantitative ultrasound backscatter microscopy\",\"authors\":\"A. Saied, B. Dehecq, M. Savoldelli, B. Briat, J. Legeais, G. Berger\",\"doi\":\"10.1109/ULTSYM.1997.661770\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In a previous preliminary study the authors have shown that 50 MHz ultrasound microscope coupled with the spectral analysis of radio frequency signal enable the imaging and evaluation of the biointegration of polymer implants used as support of keratoprosthesis (artificial cornea). In particular, the authors have demonstrated that the level of apparent backscatter was sensitive to the change in the polymer pore content (fluid or cells). In the current study, a larger number of polymer implants (n=21) at different colonization stages were explored in vitro and the authors investigated the potential of the frequency variation of both ultrasonic backscatter and attenuation coefficients to control and assess in situ the progressive biocolonization of the material. Quantitative echographic findings were correlated to histologic data which established the cell density in each specimen.\",\"PeriodicalId\":6369,\"journal\":{\"name\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"volume\":\"33 1\",\"pages\":\"1093-1096 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1997.661770\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.661770","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在之前的初步研究中,作者已经表明,50 MHz超声显微镜与射频信号的频谱分析相结合,可以成像和评估用作人工角膜支撑的聚合物植入物的生物整合性。特别是,作者已经证明,表观后向散射水平对聚合物孔隙含量(流体或细胞)的变化很敏感。在目前的研究中,研究人员在体外探索了大量不同定植阶段的聚合物植入物(n=21),并研究了超声后向散射和衰减系数的频率变化潜力,以控制和评估材料的生物定植进展。定量超声结果与组织学数据相关联,确定了每个标本的细胞密度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of keratoprosthesis biointegration in situ with quantitative ultrasound backscatter microscopy
In a previous preliminary study the authors have shown that 50 MHz ultrasound microscope coupled with the spectral analysis of radio frequency signal enable the imaging and evaluation of the biointegration of polymer implants used as support of keratoprosthesis (artificial cornea). In particular, the authors have demonstrated that the level of apparent backscatter was sensitive to the change in the polymer pore content (fluid or cells). In the current study, a larger number of polymer implants (n=21) at different colonization stages were explored in vitro and the authors investigated the potential of the frequency variation of both ultrasonic backscatter and attenuation coefficients to control and assess in situ the progressive biocolonization of the material. Quantitative echographic findings were correlated to histologic data which established the cell density in each specimen.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diamond wafer for SAW application High contrast images of defects in food package seals New properties of the SAW gas sensing Electromagnetic acoustic resonance for studying dislocation formation in polycrystalline pure copper during deformation A new design of ultrasonic air-coupled ribbon transducer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1