下颌覆盖义齿不同定位器高度的生物反应。

Helmy Abdelhafiz, M. Elmahdy, Sayed Elmasry, H. A. Abd El-Hamid
{"title":"下颌覆盖义齿不同定位器高度的生物反应。","authors":"Helmy Abdelhafiz, M. Elmahdy, Sayed Elmasry, H. A. Abd El-Hamid","doi":"10.21608/dsu.2021.45428.1050","DOIUrl":null,"url":null,"abstract":"Introduction: The locator attachment has been widely and successfully used to support dentures has dual retention and is available in different heights with different retention values; in addition, their repair and replacement are quick and straight forward. Aim: The aim of this study was to compare clinically and radio graphically the biological effect of two different locator heights on peri-implant bone width and probing depth in mandibular implant overdenture wearers. Materials and methods: Conventional complete dentures were constructed for twelve completely edentulous male patients, chosen from Out-clinic of faculty of dentistry Suez Canal University. Two implant were inserted in the lower cusped region then the patients divided randomly into two groups Group A(GA): Six patients received implant retained over denture with 1mm locator height. Group B (GB): Six patients received implant retained over denture with 3mm locator height, the follow up both clinically and radiography were taken at 0, 6, 12 and 18 months starting from the first day of over denture attachment pick up. Peri-implant bone width and probing depth were estimated through the evaluation periods. Results: It was found that the reduction in the peri-implant alveolar buccolingual width and probing depth around the implants were higher in GA than GB at all follow up periods, except for the last follow up period. Conclusion: The locator height has a biological effect on bone width and probing depth as the higher locator height the more preservation of peri-implant bone.","PeriodicalId":11270,"journal":{"name":"Dental Science Updates","volume":"11 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biological Response of Different Locator Heights in Mandibular Overdenture Wearers .\",\"authors\":\"Helmy Abdelhafiz, M. Elmahdy, Sayed Elmasry, H. A. Abd El-Hamid\",\"doi\":\"10.21608/dsu.2021.45428.1050\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: The locator attachment has been widely and successfully used to support dentures has dual retention and is available in different heights with different retention values; in addition, their repair and replacement are quick and straight forward. Aim: The aim of this study was to compare clinically and radio graphically the biological effect of two different locator heights on peri-implant bone width and probing depth in mandibular implant overdenture wearers. Materials and methods: Conventional complete dentures were constructed for twelve completely edentulous male patients, chosen from Out-clinic of faculty of dentistry Suez Canal University. Two implant were inserted in the lower cusped region then the patients divided randomly into two groups Group A(GA): Six patients received implant retained over denture with 1mm locator height. Group B (GB): Six patients received implant retained over denture with 3mm locator height, the follow up both clinically and radiography were taken at 0, 6, 12 and 18 months starting from the first day of over denture attachment pick up. Peri-implant bone width and probing depth were estimated through the evaluation periods. Results: It was found that the reduction in the peri-implant alveolar buccolingual width and probing depth around the implants were higher in GA than GB at all follow up periods, except for the last follow up period. Conclusion: The locator height has a biological effect on bone width and probing depth as the higher locator height the more preservation of peri-implant bone.\",\"PeriodicalId\":11270,\"journal\":{\"name\":\"Dental Science Updates\",\"volume\":\"11 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Science Updates\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/dsu.2021.45428.1050\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Science Updates","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/dsu.2021.45428.1050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

定位器附件已被广泛成功地用于支持具有双重固位的义齿,并可在不同高度具有不同固位值;此外,他们的维修和更换是快速和直接的。目的:比较两种定位器高度对下颌种植覆盖义齿种植周骨宽度和探入深度的生物学影响。材料与方法:选择苏伊士运河大学牙科学院门诊部的12例男性全牙缺失患者进行常规全口义齿的修复。A组(GA): 6例患者采用定位器高度为1mm的义齿保留种植体。B组(GB): 6例患者采用定位器高度为3mm的种植体固位冠义齿,从冠义齿附着体拾取第1天起,分别于0、6、12、18个月进行临床随访和影像学随访。通过评估期估计种植体周围骨宽度和探探深度。结果:除最后一次随访外,GA组种植体周围牙槽齿颊舌宽度和探探深度的减少在所有随访期间均高于GB组。结论:定位器高度对骨宽度和探深有生物效应,定位器高度越高,种植体周围骨保存越好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Biological Response of Different Locator Heights in Mandibular Overdenture Wearers .
Introduction: The locator attachment has been widely and successfully used to support dentures has dual retention and is available in different heights with different retention values; in addition, their repair and replacement are quick and straight forward. Aim: The aim of this study was to compare clinically and radio graphically the biological effect of two different locator heights on peri-implant bone width and probing depth in mandibular implant overdenture wearers. Materials and methods: Conventional complete dentures were constructed for twelve completely edentulous male patients, chosen from Out-clinic of faculty of dentistry Suez Canal University. Two implant were inserted in the lower cusped region then the patients divided randomly into two groups Group A(GA): Six patients received implant retained over denture with 1mm locator height. Group B (GB): Six patients received implant retained over denture with 3mm locator height, the follow up both clinically and radiography were taken at 0, 6, 12 and 18 months starting from the first day of over denture attachment pick up. Peri-implant bone width and probing depth were estimated through the evaluation periods. Results: It was found that the reduction in the peri-implant alveolar buccolingual width and probing depth around the implants were higher in GA than GB at all follow up periods, except for the last follow up period. Conclusion: The locator height has a biological effect on bone width and probing depth as the higher locator height the more preservation of peri-implant bone.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
EFFECT OF GAMMA-RADIATION ON DE- AND RE-MINERALIZATION OF ENAMEL AND DENTIN (An IN-VITRO STUDY) Comparison of Upper and Lower Canine Retraction Rates Assisted by Flapless Laser Corticotomy. Evaluation of Position and Treatment Difficulty of Impacted Maxillary Canine Using Cone Beam Computed Tomography: A Retrospective Study Histological and Molecular Assessment of Anti-inflammatory Effect of Different Concentrations of Hyaluronic Acid Injected in Inflamed Rabbit’s Tempromandibular Joint Effect of Using Two Different Techniques of Denture Base Fabrication on Retention of Maxillary Complete Denture: An in Vivo Comparative Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1