波纹板翅片散热器的强化传热

IF 0.4 4区 工程技术 Q4 NUCLEAR SCIENCE & TECHNOLOGY Kerntechnik Pub Date : 2023-03-30 DOI:10.1515/kern-2022-0114
Alen Mathew Jose, M. Kumar, A. Patil
{"title":"波纹板翅片散热器的强化传热","authors":"Alen Mathew Jose, M. Kumar, A. Patil","doi":"10.1515/kern-2022-0114","DOIUrl":null,"url":null,"abstract":"Abstract To design a compact heat sink, a simplified geometry, enhanced heat dissipation, and the minimum pressure drop should be taken into consideration. With this objective, an experimental investigation has been conducted with the corrugated plate-fin heat sink by varying the relative radius of corrugation and relative corrugation pitch in the range of 0.16–0.31, and 0.06–0.16, respectively, for the Reynolds number range of 6000–14,000. Experiments were conducted on a corrugated plate-fin heat sink using an open-loop experimental system comprising a test section of a rectangular channel measuring 2300 mm long, 180 mm wide, and 80 mm high. The corrugated fin creates higher disturbances caused by multiple separations and reattachments in the flow and thereby yielding a higher localized heat transfer coefficient and enhanced heat transfer from the system. The maximum fin performance is found to be 5.87 for the corrugated plate-fin heat sink corresponding to the relative radius of corrugation and relative corrugation pitch of 0.16 and 0.125, respectively.","PeriodicalId":17787,"journal":{"name":"Kerntechnik","volume":"2008 1","pages":"262 - 272"},"PeriodicalIF":0.4000,"publicationDate":"2023-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhanced heat transfer in corrugated plate fin heat sink\",\"authors\":\"Alen Mathew Jose, M. Kumar, A. Patil\",\"doi\":\"10.1515/kern-2022-0114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract To design a compact heat sink, a simplified geometry, enhanced heat dissipation, and the minimum pressure drop should be taken into consideration. With this objective, an experimental investigation has been conducted with the corrugated plate-fin heat sink by varying the relative radius of corrugation and relative corrugation pitch in the range of 0.16–0.31, and 0.06–0.16, respectively, for the Reynolds number range of 6000–14,000. Experiments were conducted on a corrugated plate-fin heat sink using an open-loop experimental system comprising a test section of a rectangular channel measuring 2300 mm long, 180 mm wide, and 80 mm high. The corrugated fin creates higher disturbances caused by multiple separations and reattachments in the flow and thereby yielding a higher localized heat transfer coefficient and enhanced heat transfer from the system. The maximum fin performance is found to be 5.87 for the corrugated plate-fin heat sink corresponding to the relative radius of corrugation and relative corrugation pitch of 0.16 and 0.125, respectively.\",\"PeriodicalId\":17787,\"journal\":{\"name\":\"Kerntechnik\",\"volume\":\"2008 1\",\"pages\":\"262 - 272\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2023-03-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kerntechnik\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1515/kern-2022-0114\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kerntechnik","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1515/kern-2022-0114","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

设计紧凑的散热器时,应考虑简化几何形状、增强散热能力和使压降最小。为此,在雷诺数为6000 ~ 14000的条件下,通过改变波纹相对半径和相对波纹节距分别为0.16 ~ 0.31和0.06 ~ 0.16,对波纹板翅片散热器进行了实验研究。采用开环实验系统对波纹板翅散热器进行了实验,该实验系统包括长2300mm、宽180mm、高80mm的矩形通道的测试段。波纹翅片在流动中产生由多次分离和再附着引起的更高扰动,从而产生更高的局部传热系数和增强的系统传热。当相对波纹半径和相对波纹节距分别为0.16和0.125时,波纹板翅片散热器的最大翅片性能为5.87。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Enhanced heat transfer in corrugated plate fin heat sink
Abstract To design a compact heat sink, a simplified geometry, enhanced heat dissipation, and the minimum pressure drop should be taken into consideration. With this objective, an experimental investigation has been conducted with the corrugated plate-fin heat sink by varying the relative radius of corrugation and relative corrugation pitch in the range of 0.16–0.31, and 0.06–0.16, respectively, for the Reynolds number range of 6000–14,000. Experiments were conducted on a corrugated plate-fin heat sink using an open-loop experimental system comprising a test section of a rectangular channel measuring 2300 mm long, 180 mm wide, and 80 mm high. The corrugated fin creates higher disturbances caused by multiple separations and reattachments in the flow and thereby yielding a higher localized heat transfer coefficient and enhanced heat transfer from the system. The maximum fin performance is found to be 5.87 for the corrugated plate-fin heat sink corresponding to the relative radius of corrugation and relative corrugation pitch of 0.16 and 0.125, respectively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Kerntechnik
Kerntechnik 工程技术-核科学技术
CiteScore
0.90
自引率
20.00%
发文量
72
审稿时长
6-12 weeks
期刊介绍: Kerntechnik is an independent journal for nuclear engineering (including design, operation, safety and economics of nuclear power stations, research reactors and simulators), energy systems, radiation (ionizing radiation in industry, medicine and research) and radiological protection (biological effects of ionizing radiation, the system of protection for occupational, medical and public exposures, the assessment of doses, operational protection and safety programs, management of radioactive wastes, decommissioning and regulatory requirements).
期刊最新文献
Evaluation of the optimum safety performance of the nuclear reactor compact grounding system under lightning strikes and ground fault CFD and machine learning based hybrid model for passive dilution of helium in a top ventilated compartment Probing 6He induced reactions with nuclear level density Neutronic and thermal-hydraulic assessment of the TRR with new core designed based on tubular fuels An application for nonlinear heterogeneity-based isotherm models in characterization of niobium sorption on clay rocks and granite
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1