{"title":"埃塞俄比亚亚的斯亚贝巴市涂料工业废水中物理化学和重金属浓度的评价","authors":"Dessalew Berihun, Yonas Solomon","doi":"10.4172/2252-5211.1000306","DOIUrl":null,"url":null,"abstract":"Paint industry is one of the industries that cause the water pollution by generating Wastewater primarily due to cleaning operations of mixers, reactors, blenders, packing machines and floors. The present research work deals with the study of some of the important physico-chemical and heavy metal parameters of paint industrial waste water effluents which was aimed at the analysis of the untreated effluents from six paint factories in Addis Ababa and the surrounding area. Analysis physico-chemical and heavy metal parameters of selected paint factories samples in Kadisco (KA), Zemilli (ZE), Rainbow (RA), Gastor solar (GA), Nifas silk (NI) and Modern building industry (MBI) were performed to investigate the concentration of status of the parameter. In this study, like; physico-chemical and heavy metal parameters pH, EC, TDS, TSS, COD, Cd, Cr, Pb, and Zn of the nine wastewater samples were analyzed using, Dana multi-meter, Jenway Model 4510 Conductivity/Temp Meter (451 001), Gravimetric, Volumetric, Colorimetric, flame emission photometry, and Atomic Absorption spectrometry (AAS)analyses methods. In the investigation some parameters were found to be above the limit set by ES and WHO. Values obtained for pH at KA, ZE,RA,GA, NI and MBI were 7.95, 8.34, 7.68, 10.95, 7.85 and 8.41; E.C:-55.1, 3.149, 675.9, 2.417, 549.6 and 3.169. TSS:-63, 205, 80, 55, 1980 and 418 mg/l and TDS:-501, 1, 2.849, 615.2, 2.207 and 2.883mg/l and COD:- 100, 340, 270, 140, 2190 and 2670 mg/l. On the other hand, results obtained from Atomic Absorption Spectrophotometer analysis (AAS) showed the average metal levels as Cd2+, Cr Pb2 and Zn2+ were all sites above the permissible limit set by ES and WHO (detected mg/L).","PeriodicalId":14393,"journal":{"name":"International Journal of Waste Resources","volume":"2016 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Assessment of the Physicochemical and Heavy Metal Concentration from Effluents of Paint Industry in Addis Ababa, Ethiopia\",\"authors\":\"Dessalew Berihun, Yonas Solomon\",\"doi\":\"10.4172/2252-5211.1000306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Paint industry is one of the industries that cause the water pollution by generating Wastewater primarily due to cleaning operations of mixers, reactors, blenders, packing machines and floors. The present research work deals with the study of some of the important physico-chemical and heavy metal parameters of paint industrial waste water effluents which was aimed at the analysis of the untreated effluents from six paint factories in Addis Ababa and the surrounding area. Analysis physico-chemical and heavy metal parameters of selected paint factories samples in Kadisco (KA), Zemilli (ZE), Rainbow (RA), Gastor solar (GA), Nifas silk (NI) and Modern building industry (MBI) were performed to investigate the concentration of status of the parameter. In this study, like; physico-chemical and heavy metal parameters pH, EC, TDS, TSS, COD, Cd, Cr, Pb, and Zn of the nine wastewater samples were analyzed using, Dana multi-meter, Jenway Model 4510 Conductivity/Temp Meter (451 001), Gravimetric, Volumetric, Colorimetric, flame emission photometry, and Atomic Absorption spectrometry (AAS)analyses methods. In the investigation some parameters were found to be above the limit set by ES and WHO. Values obtained for pH at KA, ZE,RA,GA, NI and MBI were 7.95, 8.34, 7.68, 10.95, 7.85 and 8.41; E.C:-55.1, 3.149, 675.9, 2.417, 549.6 and 3.169. TSS:-63, 205, 80, 55, 1980 and 418 mg/l and TDS:-501, 1, 2.849, 615.2, 2.207 and 2.883mg/l and COD:- 100, 340, 270, 140, 2190 and 2670 mg/l. On the other hand, results obtained from Atomic Absorption Spectrophotometer analysis (AAS) showed the average metal levels as Cd2+, Cr Pb2 and Zn2+ were all sites above the permissible limit set by ES and WHO (detected mg/L).\",\"PeriodicalId\":14393,\"journal\":{\"name\":\"International Journal of Waste Resources\",\"volume\":\"2016 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Waste Resources\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2252-5211.1000306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Waste Resources","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2252-5211.1000306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
摘要
涂料行业是造成水污染的行业之一,主要是由于搅拌器、反应器、搅拌器、包装机和地板的清洁操作而产生废水。本研究对亚的斯亚贝巴及周边地区6家油漆厂的未处理废水进行了理化和重金属参数分析。选取Kadisco (KA)、Zemilli (ZE)、Rainbow (RA)、Gastor solar (GA)、Nifas silk (NI)和Modern building industry (MBI)等地区的涂料工厂样品进行理化和重金属参数分析,了解这些参数的浓度状况。在这项研究中,比如;采用Dana万用表、Jenway 4510型电导率/温度计(451 001)、重量法、体积法、比色法、火焰发射光度法和原子吸收光谱(AAS)等分析方法,对9个废水样品的理化和重金属参数pH、EC、TDS、TSS、COD、Cd、Cr、Pb、Zn进行了分析。在调查中,发现一些参数超过了ES和WHO规定的限值。KA、ZE、RA、GA、NI和MBI的pH值分别为7.95、8.34、7.68、10.95、7.85和8.41;例如:-55.1,3.149,675.9,2.417,549.6和3.169。TSS:-63、205、80、55、1980和418 mg/l, TDS:-501、1、2.849、615.2、2.207和2.883mg/l, COD:- 100、340、270、140、2190和2670 mg/l。原子吸收分光光度法(AAS)分析结果显示,样品中Cd2+、Cr Pb2和Zn2+的平均含量均高于ES和WHO规定的允许限量(检测mg/L)。
Assessment of the Physicochemical and Heavy Metal Concentration from Effluents of Paint Industry in Addis Ababa, Ethiopia
Paint industry is one of the industries that cause the water pollution by generating Wastewater primarily due to cleaning operations of mixers, reactors, blenders, packing machines and floors. The present research work deals with the study of some of the important physico-chemical and heavy metal parameters of paint industrial waste water effluents which was aimed at the analysis of the untreated effluents from six paint factories in Addis Ababa and the surrounding area. Analysis physico-chemical and heavy metal parameters of selected paint factories samples in Kadisco (KA), Zemilli (ZE), Rainbow (RA), Gastor solar (GA), Nifas silk (NI) and Modern building industry (MBI) were performed to investigate the concentration of status of the parameter. In this study, like; physico-chemical and heavy metal parameters pH, EC, TDS, TSS, COD, Cd, Cr, Pb, and Zn of the nine wastewater samples were analyzed using, Dana multi-meter, Jenway Model 4510 Conductivity/Temp Meter (451 001), Gravimetric, Volumetric, Colorimetric, flame emission photometry, and Atomic Absorption spectrometry (AAS)analyses methods. In the investigation some parameters were found to be above the limit set by ES and WHO. Values obtained for pH at KA, ZE,RA,GA, NI and MBI were 7.95, 8.34, 7.68, 10.95, 7.85 and 8.41; E.C:-55.1, 3.149, 675.9, 2.417, 549.6 and 3.169. TSS:-63, 205, 80, 55, 1980 and 418 mg/l and TDS:-501, 1, 2.849, 615.2, 2.207 and 2.883mg/l and COD:- 100, 340, 270, 140, 2190 and 2670 mg/l. On the other hand, results obtained from Atomic Absorption Spectrophotometer analysis (AAS) showed the average metal levels as Cd2+, Cr Pb2 and Zn2+ were all sites above the permissible limit set by ES and WHO (detected mg/L).