Yoko Mikami, Y. Takagi, H. Miyakawa, Y. Yamajima, Narue Sakamaki, C. Kobayashi
{"title":"快速高效液相色谱法测定食品中抗氧化剂及标准溶液贮存稳定性的研究","authors":"Yoko Mikami, Y. Takagi, H. Miyakawa, Y. Yamajima, Narue Sakamaki, C. Kobayashi","doi":"10.3358/shokueishi.63.12","DOIUrl":null,"url":null,"abstract":"In this study, we simultaneously determined three antioxidants, butylated hydroxytoluene (BHT), butylated hydroxyanisole (BHA), and tert-butylhydroquinone (TBHQ), using HPLC equipped both with a photodiode array detector and a fluorescence detector in 25 minutes per sample. Due to the combined use of the two detectors, we could achieve improved target selectivity. Further, quantification at the specific wavelengths for each target substance particularly increased BHT detection sensitivity. This approach enabled us to avoid repeated measurements during daily inspections. Furthermore, detections were performed using LC-MS/MS instead of GC-MS to overcome the problem of helium gas shortage.In addition, we investigated antioxidant stability in standard solutions during storage. Although TBHQ was stable in methanol with ascorbic acid at -20℃, ascorbic acid storage has possibility to lead to decrease in BHT and BHA concentrations. We recognized that the mixture of BHT and BHA dissolved in methanol at 4℃ and that of BHT, BHA and TBHQ dissolved in methanol with ascorbic acid at -20℃ were suitable for about one year.","PeriodicalId":54373,"journal":{"name":"Food Hygiene and Safety Science","volume":"19 1","pages":"12-19"},"PeriodicalIF":0.2000,"publicationDate":"2022-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"[Study of Rapid HPLC Method for the Determination of Antioxidants in Foods, and Standard Solution Stability during Storage].\",\"authors\":\"Yoko Mikami, Y. Takagi, H. Miyakawa, Y. Yamajima, Narue Sakamaki, C. Kobayashi\",\"doi\":\"10.3358/shokueishi.63.12\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, we simultaneously determined three antioxidants, butylated hydroxytoluene (BHT), butylated hydroxyanisole (BHA), and tert-butylhydroquinone (TBHQ), using HPLC equipped both with a photodiode array detector and a fluorescence detector in 25 minutes per sample. Due to the combined use of the two detectors, we could achieve improved target selectivity. Further, quantification at the specific wavelengths for each target substance particularly increased BHT detection sensitivity. This approach enabled us to avoid repeated measurements during daily inspections. Furthermore, detections were performed using LC-MS/MS instead of GC-MS to overcome the problem of helium gas shortage.In addition, we investigated antioxidant stability in standard solutions during storage. Although TBHQ was stable in methanol with ascorbic acid at -20℃, ascorbic acid storage has possibility to lead to decrease in BHT and BHA concentrations. We recognized that the mixture of BHT and BHA dissolved in methanol at 4℃ and that of BHT, BHA and TBHQ dissolved in methanol with ascorbic acid at -20℃ were suitable for about one year.\",\"PeriodicalId\":54373,\"journal\":{\"name\":\"Food Hygiene and Safety Science\",\"volume\":\"19 1\",\"pages\":\"12-19\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Hygiene and Safety Science\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.3358/shokueishi.63.12\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Hygiene and Safety Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3358/shokueishi.63.12","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
[Study of Rapid HPLC Method for the Determination of Antioxidants in Foods, and Standard Solution Stability during Storage].
In this study, we simultaneously determined three antioxidants, butylated hydroxytoluene (BHT), butylated hydroxyanisole (BHA), and tert-butylhydroquinone (TBHQ), using HPLC equipped both with a photodiode array detector and a fluorescence detector in 25 minutes per sample. Due to the combined use of the two detectors, we could achieve improved target selectivity. Further, quantification at the specific wavelengths for each target substance particularly increased BHT detection sensitivity. This approach enabled us to avoid repeated measurements during daily inspections. Furthermore, detections were performed using LC-MS/MS instead of GC-MS to overcome the problem of helium gas shortage.In addition, we investigated antioxidant stability in standard solutions during storage. Although TBHQ was stable in methanol with ascorbic acid at -20℃, ascorbic acid storage has possibility to lead to decrease in BHT and BHA concentrations. We recognized that the mixture of BHT and BHA dissolved in methanol at 4℃ and that of BHT, BHA and TBHQ dissolved in methanol with ascorbic acid at -20℃ were suitable for about one year.