{"title":"火力发电厂","authors":"Kenneth H. Sebra","doi":"10.1201/9781315222424-7","DOIUrl":null,"url":null,"abstract":"Kenneth H. Sebra Baltimore Gas and Electric Company 6.1 Plant Auxiliary System 6-2 Selection of Auxiliary System Voltages . Auxiliary System Loads . Auxiliary System Power Sources . Auxiliary System Voltage Regulation Requirements 6.2 Plant One-Line Diagram 6-3 6.3 Plant Equipment Voltage Ratings 6-3 6.4 Grounded vs. Ungrounded Systems 6-3 Ungrounded . Grounded . Low-Resistance Grounding . High-Resistance Grounding 6.5 Miscellaneous Circuits 6-3 Essential Services . Lighting Supply 6.6 DC Systems 6-4 125-V DC . 250-V DC 6.7 Power Plant Switchgear 6-4 High-Voltage Circuit Breakers . Medium-Voltage Switchgear . Low-Voltage Switchgear . Motor Control Centers . Circuit Interruption 6.8 Auxiliary Transformers 6-5 Selection of Percent Impedance . Rating of Voltage Taps 6.9 Motors 6-6 Selection of Motors . Types of Motors 6.10 Main Generator 6-6 Associated Equipment . Electronic Exciters . Generator Neutral Grounding . Isolated Phase Bus 6.11 Cable 6-7 6.12 Electrical Analysis 6-7 Load Flow . Short-Circuit Analysis . Surge Protection . Phasing . Relay Coordination Studies 6.13 Maintenance and Testing 6-8 6.14 Start-Up 6-8","PeriodicalId":64189,"journal":{"name":"中国电业","volume":"os-8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal Generating Plants\",\"authors\":\"Kenneth H. Sebra\",\"doi\":\"10.1201/9781315222424-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Kenneth H. Sebra Baltimore Gas and Electric Company 6.1 Plant Auxiliary System 6-2 Selection of Auxiliary System Voltages . Auxiliary System Loads . Auxiliary System Power Sources . Auxiliary System Voltage Regulation Requirements 6.2 Plant One-Line Diagram 6-3 6.3 Plant Equipment Voltage Ratings 6-3 6.4 Grounded vs. Ungrounded Systems 6-3 Ungrounded . Grounded . Low-Resistance Grounding . High-Resistance Grounding 6.5 Miscellaneous Circuits 6-3 Essential Services . Lighting Supply 6.6 DC Systems 6-4 125-V DC . 250-V DC 6.7 Power Plant Switchgear 6-4 High-Voltage Circuit Breakers . Medium-Voltage Switchgear . Low-Voltage Switchgear . Motor Control Centers . Circuit Interruption 6.8 Auxiliary Transformers 6-5 Selection of Percent Impedance . Rating of Voltage Taps 6.9 Motors 6-6 Selection of Motors . Types of Motors 6.10 Main Generator 6-6 Associated Equipment . Electronic Exciters . Generator Neutral Grounding . Isolated Phase Bus 6.11 Cable 6-7 6.12 Electrical Analysis 6-7 Load Flow . Short-Circuit Analysis . Surge Protection . Phasing . Relay Coordination Studies 6.13 Maintenance and Testing 6-8 6.14 Start-Up 6-8\",\"PeriodicalId\":64189,\"journal\":{\"name\":\"中国电业\",\"volume\":\"os-8 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国电业\",\"FirstCategoryId\":\"1092\",\"ListUrlMain\":\"https://doi.org/10.1201/9781315222424-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国电业","FirstCategoryId":"1092","ListUrlMain":"https://doi.org/10.1201/9781315222424-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0