K. Ishikawa, Masashi Nako, Shu’ya Sato, Y. Akiyama
{"title":"实时测量盐浓度以评估食品在腌制过程中的适宜浸渍状态","authors":"K. Ishikawa, Masashi Nako, Shu’ya Sato, Y. Akiyama","doi":"10.5188/ijsmer.23.225","DOIUrl":null,"url":null,"abstract":"were still in the glass case. The stainless steel rod electrodes that had been fi lm-coated by insulating spray were inserted into the food interior to measure the impedance of the surface, upper, middle, and the lower regions of the food (Figure 1). After sprinkling various amounts of NaCl all over the gel surfaces, the impedance values of gels were measured using an Inductance Capacitance and Residence (LCR) meter (3523-50; Hioki E. E. Corp., Japan). The sample impedance For this study, we developed a novel real-time monitoring system using a stainless steel electrode to assess NaCl osmosis in the food interior by measuring electrical impedance. The NaCl penetration into agar gel sprayed with NaCl on the surface was evaluated using impedance. As the measured position of the electrode moves downward, a longer time is needed to obtain a constant impedance value. Measurement of the chloride concentrations in the model food that had been cut into four pieces (surface, upper, middle, and lower parts) revealed an extremely strong relation between the equilibrium period of the impedance value and the inner chloride concentrations of the model. Results con fi rmed that a similar impedance value was obtained if the concentration of NaCl sprinkled on the top of the gels was the same irrespective of points measured using the electrode. These results demonstrate that this impedance measurement method using an LCR meter is useful for real-time monitoring of NaCl osmosis in the food interior.","PeriodicalId":14339,"journal":{"name":"International journal of the Society of Materials Engineering for Resources","volume":"33 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of Real-Time Measurement of Salinity Concentration to Evaluate Suitable Food Dipping States During Salting\",\"authors\":\"K. Ishikawa, Masashi Nako, Shu’ya Sato, Y. Akiyama\",\"doi\":\"10.5188/ijsmer.23.225\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"were still in the glass case. The stainless steel rod electrodes that had been fi lm-coated by insulating spray were inserted into the food interior to measure the impedance of the surface, upper, middle, and the lower regions of the food (Figure 1). After sprinkling various amounts of NaCl all over the gel surfaces, the impedance values of gels were measured using an Inductance Capacitance and Residence (LCR) meter (3523-50; Hioki E. E. Corp., Japan). The sample impedance For this study, we developed a novel real-time monitoring system using a stainless steel electrode to assess NaCl osmosis in the food interior by measuring electrical impedance. The NaCl penetration into agar gel sprayed with NaCl on the surface was evaluated using impedance. As the measured position of the electrode moves downward, a longer time is needed to obtain a constant impedance value. Measurement of the chloride concentrations in the model food that had been cut into four pieces (surface, upper, middle, and lower parts) revealed an extremely strong relation between the equilibrium period of the impedance value and the inner chloride concentrations of the model. Results con fi rmed that a similar impedance value was obtained if the concentration of NaCl sprinkled on the top of the gels was the same irrespective of points measured using the electrode. These results demonstrate that this impedance measurement method using an LCR meter is useful for real-time monitoring of NaCl osmosis in the food interior.\",\"PeriodicalId\":14339,\"journal\":{\"name\":\"International journal of the Society of Materials Engineering for Resources\",\"volume\":\"33 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of the Society of Materials Engineering for Resources\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5188/ijsmer.23.225\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of the Society of Materials Engineering for Resources","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5188/ijsmer.23.225","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
我们还在玻璃盒子里。将经绝缘喷雾涂膜的不锈钢棒电极插入食品内部,测量食品表面、上、中、下区域的阻抗(图1)。在凝胶表面喷洒不同量的NaCl后,使用电感-电容和停留(LCR)计(3523-50;Hioki E. E. Corp.,日本)。在这项研究中,我们开发了一种新型的实时监测系统,使用不锈钢电极通过测量电阻抗来评估NaCl在食品内部的渗透。用阻抗法评价NaCl对表面喷撒NaCl的琼脂凝胶的渗透能力。由于电极的测量位置向下移动,需要更长的时间才能获得恒定的阻抗值。对切成表面、上、中、下四段的模型食品进行氯离子浓度测量,发现阻抗值的平衡周期与模型内部氯离子浓度之间存在极强的关系。结果证实,如果洒在凝胶顶部的NaCl浓度相同,无论电极测量的是什么点,都可以得到相似的阻抗值。结果表明,利用LCR仪进行阻抗测量是实时监测食品内部NaCl渗透的有效方法。
Development of Real-Time Measurement of Salinity Concentration to Evaluate Suitable Food Dipping States During Salting
were still in the glass case. The stainless steel rod electrodes that had been fi lm-coated by insulating spray were inserted into the food interior to measure the impedance of the surface, upper, middle, and the lower regions of the food (Figure 1). After sprinkling various amounts of NaCl all over the gel surfaces, the impedance values of gels were measured using an Inductance Capacitance and Residence (LCR) meter (3523-50; Hioki E. E. Corp., Japan). The sample impedance For this study, we developed a novel real-time monitoring system using a stainless steel electrode to assess NaCl osmosis in the food interior by measuring electrical impedance. The NaCl penetration into agar gel sprayed with NaCl on the surface was evaluated using impedance. As the measured position of the electrode moves downward, a longer time is needed to obtain a constant impedance value. Measurement of the chloride concentrations in the model food that had been cut into four pieces (surface, upper, middle, and lower parts) revealed an extremely strong relation between the equilibrium period of the impedance value and the inner chloride concentrations of the model. Results con fi rmed that a similar impedance value was obtained if the concentration of NaCl sprinkled on the top of the gels was the same irrespective of points measured using the electrode. These results demonstrate that this impedance measurement method using an LCR meter is useful for real-time monitoring of NaCl osmosis in the food interior.