H. S. M. Vale, D. O. Costa, R. O. Batista, F. A. Oliveira, J. F. Medeiros, D. Coelho
{"title":"应用石油勘探生产的处理过的水的稀释剂的滴注装置的分布均匀性","authors":"H. S. M. Vale, D. O. Costa, R. O. Batista, F. A. Oliveira, J. F. Medeiros, D. Coelho","doi":"10.1590/1807-1929/agriambi.v24n6p394-401","DOIUrl":null,"url":null,"abstract":"ABSTRACT The objective of this study was to evaluate the uniformity of distribution in drip units applying dilutions of treated water produced by oil exploration. The experiment was set up in a completely randomized design in a split-split-plot scheme, with three replicates. The plots were composed of the treatments P0 - 100% groundwater, control; P10 - 90% groundwater and 10% produced water; P20 - 80% groundwater and 20% produced water; P30 - 70% groundwater and 30% produced water; and P40 - 60% groundwater and 40% produced water; the subplots had the types of non-pressure compensating drippers (D1 - 1.6 L h-1, Netafim Super Typhoon, D2 - 1.6 L h-1, Netafim Streamline and D3 - 1.7 L h-1, NaanDanJain TalDrip); and the sub-subplots contained the evaluation times (0, 40, 80, 120 and 160 h). Distribution uniformity and statistical uniformity coefficients were evaluated every 40 h, until completing 160 h. The pH of the dilutions was the attribute posing the highest risk of clogging to the emitters. Also in relation to dilutions, P40 caused greater application non-uniformity in D2, while the highest values of application uniformity were achieved in treatments P10 and P20 with D1 and D3, indicating the effectiveness of dilution in minimizing clogging.","PeriodicalId":51288,"journal":{"name":"Revista Brasileira de Engenharia Agricola e Ambiental","volume":"28 1","pages":"394-401"},"PeriodicalIF":1.4000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Distribution uniformity in drip units applying dilutions of treated water produced by oil exploration\",\"authors\":\"H. S. M. Vale, D. O. Costa, R. O. Batista, F. A. Oliveira, J. F. Medeiros, D. Coelho\",\"doi\":\"10.1590/1807-1929/agriambi.v24n6p394-401\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT The objective of this study was to evaluate the uniformity of distribution in drip units applying dilutions of treated water produced by oil exploration. The experiment was set up in a completely randomized design in a split-split-plot scheme, with three replicates. The plots were composed of the treatments P0 - 100% groundwater, control; P10 - 90% groundwater and 10% produced water; P20 - 80% groundwater and 20% produced water; P30 - 70% groundwater and 30% produced water; and P40 - 60% groundwater and 40% produced water; the subplots had the types of non-pressure compensating drippers (D1 - 1.6 L h-1, Netafim Super Typhoon, D2 - 1.6 L h-1, Netafim Streamline and D3 - 1.7 L h-1, NaanDanJain TalDrip); and the sub-subplots contained the evaluation times (0, 40, 80, 120 and 160 h). Distribution uniformity and statistical uniformity coefficients were evaluated every 40 h, until completing 160 h. The pH of the dilutions was the attribute posing the highest risk of clogging to the emitters. Also in relation to dilutions, P40 caused greater application non-uniformity in D2, while the highest values of application uniformity were achieved in treatments P10 and P20 with D1 and D3, indicating the effectiveness of dilution in minimizing clogging.\",\"PeriodicalId\":51288,\"journal\":{\"name\":\"Revista Brasileira de Engenharia Agricola e Ambiental\",\"volume\":\"28 1\",\"pages\":\"394-401\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira de Engenharia Agricola e Ambiental\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1590/1807-1929/agriambi.v24n6p394-401\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"AGRICULTURAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Engenharia Agricola e Ambiental","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1590/1807-1929/agriambi.v24n6p394-401","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AGRICULTURAL ENGINEERING","Score":null,"Total":0}
引用次数: 3
摘要
摘要:本研究的目的是利用石油勘探产出的处理水的稀释剂来评价滴灌装置中分布的均匀性。试验采用完全随机设计,分-分-图设计,设3个重复。样地由P0 ~ 100%地下水处理组成,对照;P10 - 90%地下水和10%采出水;P20 - 80%地下水和20%采出水;P30 - 70%地下水和30%采出水;P40—60%地下水和40%采出水;子图为无压力补偿型滴流器(D1 ~ 1.6 L h-1, Netafim Super Typhoon, D2 ~ 1.6 L h-1, Netafim Streamline, D3 ~ 1.7 L h-1, NaanDanJain TalDrip);每隔40 h评估一次分布均匀性和统计均匀性系数,直至完成160 h。稀释液的pH值是对排放者造成堵塞风险最高的属性。同样与稀释相比,P40在D2中造成了更大的施用不均匀性,而D1和D3在P10和P20处理中达到了最高的施用均匀性,表明稀释在减少堵塞方面的有效性。
Distribution uniformity in drip units applying dilutions of treated water produced by oil exploration
ABSTRACT The objective of this study was to evaluate the uniformity of distribution in drip units applying dilutions of treated water produced by oil exploration. The experiment was set up in a completely randomized design in a split-split-plot scheme, with three replicates. The plots were composed of the treatments P0 - 100% groundwater, control; P10 - 90% groundwater and 10% produced water; P20 - 80% groundwater and 20% produced water; P30 - 70% groundwater and 30% produced water; and P40 - 60% groundwater and 40% produced water; the subplots had the types of non-pressure compensating drippers (D1 - 1.6 L h-1, Netafim Super Typhoon, D2 - 1.6 L h-1, Netafim Streamline and D3 - 1.7 L h-1, NaanDanJain TalDrip); and the sub-subplots contained the evaluation times (0, 40, 80, 120 and 160 h). Distribution uniformity and statistical uniformity coefficients were evaluated every 40 h, until completing 160 h. The pH of the dilutions was the attribute posing the highest risk of clogging to the emitters. Also in relation to dilutions, P40 caused greater application non-uniformity in D2, while the highest values of application uniformity were achieved in treatments P10 and P20 with D1 and D3, indicating the effectiveness of dilution in minimizing clogging.
期刊介绍:
A Revista Brasileira de Engenharia Agrícola e Ambiental (Agriambi), periódico oficial da Asociación Latinoamericana y del Caribe de Ingeniería Agrícola (ALIA), é editada mensalmente, no formato eletrônico, pela Unidade Acadêmica de Engenharia Agrícola (UAEA) do Centro de Tecnologia e Recursos Naturais (CTRN) da Universidade Federal de Campina Grande (UFCG), destinando-se à divulgação de artigos científicos originais e inéditos, elaborados em Português, Inglês ou Espanhol. Com o auxílio de pareceres de Consultores, os artigos são aceitos ou não pela Equipe Editorial para publicação na Revista. A Agriambi aceita, também, a submissão de contribuições na modalidade de revisão de literatura.