考虑土-结构相互作用的建筑及基础设施系统阻尼特性研究

Duong Hong Tham
{"title":"考虑土-结构相互作用的建筑及基础设施系统阻尼特性研究","authors":"Duong Hong Tham","doi":"10.46223/hcmcoujs.tech.en.12.2.2480.2022","DOIUrl":null,"url":null,"abstract":"This paper studies the damping characteristics of the soil foundation under a building concerning the Soil-Structure Interaction (SSI). By considering a multi-story building resting on a piled raft foundation as a typical SSI system, subjected to an earthquake (i.e., Chi Chi earthquake, Taiwan 1999), the time-dependent responses of specified locations in the foundation are recorded and analyzed, both in-time domain and frequency domain. Referring to prior knowledge about system identification and damping, this study suggests an overwhelming approach to determining the damping ratio for analyzing more thoroughly a system of SSI systems. Results are a general procedure to establish the damping matrix, namely the Caughey damping matrix which takes several frequencies into account. A different viewpoint that the connection of superstructure and infrastructure in series could help to estimate the damping, and contribute to a wide range of system identification. All these procedures are used to predict more properly the damping characteristics of a system of structures. Suggestions over the findings would be expected to contribute a more rigorous component to the analysis of high-rise buildings in the future.","PeriodicalId":34742,"journal":{"name":"Ho Chi Minh City Open University Journal of Science Engineering and Technology","volume":"64 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Studying the damping characteristics of the system of building and infrastructure considering the Soil-Structure Interaction\",\"authors\":\"Duong Hong Tham\",\"doi\":\"10.46223/hcmcoujs.tech.en.12.2.2480.2022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper studies the damping characteristics of the soil foundation under a building concerning the Soil-Structure Interaction (SSI). By considering a multi-story building resting on a piled raft foundation as a typical SSI system, subjected to an earthquake (i.e., Chi Chi earthquake, Taiwan 1999), the time-dependent responses of specified locations in the foundation are recorded and analyzed, both in-time domain and frequency domain. Referring to prior knowledge about system identification and damping, this study suggests an overwhelming approach to determining the damping ratio for analyzing more thoroughly a system of SSI systems. Results are a general procedure to establish the damping matrix, namely the Caughey damping matrix which takes several frequencies into account. A different viewpoint that the connection of superstructure and infrastructure in series could help to estimate the damping, and contribute to a wide range of system identification. All these procedures are used to predict more properly the damping characteristics of a system of structures. Suggestions over the findings would be expected to contribute a more rigorous component to the analysis of high-rise buildings in the future.\",\"PeriodicalId\":34742,\"journal\":{\"name\":\"Ho Chi Minh City Open University Journal of Science Engineering and Technology\",\"volume\":\"64 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ho Chi Minh City Open University Journal of Science Engineering and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46223/hcmcoujs.tech.en.12.2.2480.2022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ho Chi Minh City Open University Journal of Science Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46223/hcmcoujs.tech.en.12.2.2480.2022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了考虑土-结构相互作用(SSI)的建筑物地基阻尼特性。将一桩筏基础上的多层建筑作为一种典型的SSI体系,在地震(即1999年台湾池池地震)作用下,记录和分析基础中指定位置的时相关响应,包括时域和频域。参考关于系统识别和阻尼的先验知识,本研究提出了一种压倒性的方法来确定阻尼比,以便更彻底地分析SSI系统的系统。结果是建立阻尼矩阵的一般程序,即考虑多个频率的Caughey阻尼矩阵。另一种不同的观点认为,上层建筑和基础设施串联连接可以帮助估计阻尼,并有助于大范围的系统识别。所有这些方法都用于更准确地预测结构体系的阻尼特性。对研究结果的建议有望为未来高层建筑的分析提供更严格的组成部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Studying the damping characteristics of the system of building and infrastructure considering the Soil-Structure Interaction
This paper studies the damping characteristics of the soil foundation under a building concerning the Soil-Structure Interaction (SSI). By considering a multi-story building resting on a piled raft foundation as a typical SSI system, subjected to an earthquake (i.e., Chi Chi earthquake, Taiwan 1999), the time-dependent responses of specified locations in the foundation are recorded and analyzed, both in-time domain and frequency domain. Referring to prior knowledge about system identification and damping, this study suggests an overwhelming approach to determining the damping ratio for analyzing more thoroughly a system of SSI systems. Results are a general procedure to establish the damping matrix, namely the Caughey damping matrix which takes several frequencies into account. A different viewpoint that the connection of superstructure and infrastructure in series could help to estimate the damping, and contribute to a wide range of system identification. All these procedures are used to predict more properly the damping characteristics of a system of structures. Suggestions over the findings would be expected to contribute a more rigorous component to the analysis of high-rise buildings in the future.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
6
审稿时长
8 weeks
期刊最新文献
Disinfection of methicillin-resistant Staphylococcus Aureus on flat surface by 460 nm light and hydrogen peroxide combination Load-carrying capacity of circular concrete filled steel tubes under axial loading: Reliability analyses Isolation and identification of Vibrio spp. with potential ability to produce polysaccharide monooxygenase from diseased Penaeus monodon The phylogenetic authentication of Ophiocordyceps sphecocephala from Lang Biang Biosphere Reserve, Lam Dong, Vietnam Real-time PCR application in confirmation test of Salmonella Typhimurium on instant noodle
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1