B. Boyer (Professeur agrégé du Val-de-Grâce, chef du service d'imagerie médicale) , L. Hauret (Radiologiste des hôpitaux des Armées) , A.-M. Dion (Assistant des hôpitaux des Armées) , C. Aterii-Tehau (Assistant des hôpitaux des Armées) , Y.-S. Cordoliani (Professeur au Val-de-Grâce, chef du service d'imagerie médicale)
{"title":"扫描仪hélicoïdal et辐照","authors":"B. Boyer (Professeur agrégé du Val-de-Grâce, chef du service d'imagerie médicale) , L. Hauret (Radiologiste des hôpitaux des Armées) , A.-M. Dion (Assistant des hôpitaux des Armées) , C. Aterii-Tehau (Assistant des hôpitaux des Armées) , Y.-S. Cordoliani (Professeur au Val-de-Grâce, chef du service d'imagerie médicale)","doi":"10.1016/j.emcrad.2004.08.001","DOIUrl":null,"url":null,"abstract":"<div><p>After a brief review of tools used to measure radiation, we present the parameters of helical scan radiation (single and multiple slice): technical parameters (voltage, tube current) and spatial parameters (X-ray beam geometry, slice thickness, pitch). Their influence on radiation is discussed, as well as methods for adapting these parameters to obtain optimal balance between dose and imaging quality.</p></div>","PeriodicalId":100447,"journal":{"name":"EMC - Radiologie","volume":"1 5","pages":"Pages 457-469"},"PeriodicalIF":0.0000,"publicationDate":"2004-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.emcrad.2004.08.001","citationCount":"2","resultStr":"{\"title\":\"Scanner hélicoïdal et irradiation\",\"authors\":\"B. Boyer (Professeur agrégé du Val-de-Grâce, chef du service d'imagerie médicale) , L. Hauret (Radiologiste des hôpitaux des Armées) , A.-M. Dion (Assistant des hôpitaux des Armées) , C. Aterii-Tehau (Assistant des hôpitaux des Armées) , Y.-S. Cordoliani (Professeur au Val-de-Grâce, chef du service d'imagerie médicale)\",\"doi\":\"10.1016/j.emcrad.2004.08.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>After a brief review of tools used to measure radiation, we present the parameters of helical scan radiation (single and multiple slice): technical parameters (voltage, tube current) and spatial parameters (X-ray beam geometry, slice thickness, pitch). Their influence on radiation is discussed, as well as methods for adapting these parameters to obtain optimal balance between dose and imaging quality.</p></div>\",\"PeriodicalId\":100447,\"journal\":{\"name\":\"EMC - Radiologie\",\"volume\":\"1 5\",\"pages\":\"Pages 457-469\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.emcrad.2004.08.001\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EMC - Radiologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1762418504000767\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EMC - Radiologie","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1762418504000767","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
After a brief review of tools used to measure radiation, we present the parameters of helical scan radiation (single and multiple slice): technical parameters (voltage, tube current) and spatial parameters (X-ray beam geometry, slice thickness, pitch). Their influence on radiation is discussed, as well as methods for adapting these parameters to obtain optimal balance between dose and imaging quality.