基于模糊逻辑的局部放电模式识别步骤

Lury Amatullah Lumba, U. Khayam, Lunnetta Safura Lumba, Claysius Dewanata Widjaja
{"title":"基于模糊逻辑的局部放电模式识别步骤","authors":"Lury Amatullah Lumba, U. Khayam, Lunnetta Safura Lumba, Claysius Dewanata Widjaja","doi":"10.1109/ICHVEPS47643.2019.9011078","DOIUrl":null,"url":null,"abstract":"This paper discusses the method of detecting and measuring Partial Discharge using fuzzy logic. Most of insulation failures indicate Partial Discharge (PD) activity prior to the fault. Several cases show PD is the indication of insulation aging and also the cause of insulation deterioration. Further effect of PD is accelerating the insulation breakdown to occur. Many researches conclude that monitoring is important to be performed. Monitoring PD can avoid the high voltage equipment experience an early aging. Detecting PD is necessary to know the amount of PD and understand the condition of the equipment. The measurements are made using electrical methods for air insulation. The measurement results will be conducted on three level of voltages, and the results will be compared to determine the effectiveness of fuzzy logic in determining the state of the apparatus and monitoring partial discharge.","PeriodicalId":6677,"journal":{"name":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","volume":"1 1","pages":"035-039"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Step of Partial Discharge Pattern Recognition Using Fuzzy Logic\",\"authors\":\"Lury Amatullah Lumba, U. Khayam, Lunnetta Safura Lumba, Claysius Dewanata Widjaja\",\"doi\":\"10.1109/ICHVEPS47643.2019.9011078\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the method of detecting and measuring Partial Discharge using fuzzy logic. Most of insulation failures indicate Partial Discharge (PD) activity prior to the fault. Several cases show PD is the indication of insulation aging and also the cause of insulation deterioration. Further effect of PD is accelerating the insulation breakdown to occur. Many researches conclude that monitoring is important to be performed. Monitoring PD can avoid the high voltage equipment experience an early aging. Detecting PD is necessary to know the amount of PD and understand the condition of the equipment. The measurements are made using electrical methods for air insulation. The measurement results will be conducted on three level of voltages, and the results will be compared to determine the effectiveness of fuzzy logic in determining the state of the apparatus and monitoring partial discharge.\",\"PeriodicalId\":6677,\"journal\":{\"name\":\"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)\",\"volume\":\"1 1\",\"pages\":\"035-039\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVEPS47643.2019.9011078\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVEPS47643.2019.9011078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文讨论了用模糊逻辑检测和测量局部放电的方法。大多数绝缘故障在故障发生之前就预示着局部放电(PD)活动。几个案例表明,局部放电是绝缘老化的标志,也是绝缘劣化的原因。PD的进一步作用是加速绝缘击穿的发生。许多研究得出结论,监测是很重要的。监测局部放电可以避免高压设备过早老化。检测PD是了解PD量和了解设备状况的必要手段。使用电气方法对空气绝缘进行测量。测量结果将在三个电压水平上进行,并将结果进行比较,以确定模糊逻辑在确定设备状态和监测局部放电方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Step of Partial Discharge Pattern Recognition Using Fuzzy Logic
This paper discusses the method of detecting and measuring Partial Discharge using fuzzy logic. Most of insulation failures indicate Partial Discharge (PD) activity prior to the fault. Several cases show PD is the indication of insulation aging and also the cause of insulation deterioration. Further effect of PD is accelerating the insulation breakdown to occur. Many researches conclude that monitoring is important to be performed. Monitoring PD can avoid the high voltage equipment experience an early aging. Detecting PD is necessary to know the amount of PD and understand the condition of the equipment. The measurements are made using electrical methods for air insulation. The measurement results will be conducted on three level of voltages, and the results will be compared to determine the effectiveness of fuzzy logic in determining the state of the apparatus and monitoring partial discharge.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Literature Survey of Optimization Technique of Unit Commitment Implementation in Microgrid Electricity System With Renewable Energy Sources Observation of Partial Discharge Waveform of Electrical Treeing in Epoxy Resin with Filler Implementation of Over Current Relays with Non-Cascade Scheme on Medium Voltage Switchgear as Busbar Protection Study Case in PT PLN (Persero) UIT JBB Optimal Capacitor Placement For IEEE 118 Bus System By Using Genetic Algorithm An active clamped two switch flyback Zeta converter with reduced switch voltage stress
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1