{"title":"SIOM原子喷泉钟的进展","authors":"Yuanbo Du, Rong Wei, R. Dong, Fan Zou, Yu-zhu Wang","doi":"10.1109/FCS.2015.7138892","DOIUrl":null,"url":null,"abstract":"This work presents several advances in our 87Rb atomic fountain clock (AFC) at Shanghai Institute of Optics and Fine Mechanics (SIOM). We directly lock the local oscillator (LO) of AFC, and make some improvements on the physical system, including optimizing the coupling of microwave and adjusting down the working temperature of interrogation region, etc. A short-term fractional frequency stability of 2.7 × 10-13τ-1/2 is obtained by comparing the AFC with an H-maser. In accuracy evaluation of AFC, a self-comparison method is introduced, and an evaluation precision of 6 ×10-16 is obtained at the average time of 300 000 s. In addition, a GPS common view instrument is set up to compare AFC with frequency standards at other time-keeping laboratories.","PeriodicalId":57667,"journal":{"name":"时间频率公报","volume":"15 1","pages":"495-497"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advances in the atomic fountain clock at SIOM\",\"authors\":\"Yuanbo Du, Rong Wei, R. Dong, Fan Zou, Yu-zhu Wang\",\"doi\":\"10.1109/FCS.2015.7138892\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work presents several advances in our 87Rb atomic fountain clock (AFC) at Shanghai Institute of Optics and Fine Mechanics (SIOM). We directly lock the local oscillator (LO) of AFC, and make some improvements on the physical system, including optimizing the coupling of microwave and adjusting down the working temperature of interrogation region, etc. A short-term fractional frequency stability of 2.7 × 10-13τ-1/2 is obtained by comparing the AFC with an H-maser. In accuracy evaluation of AFC, a self-comparison method is introduced, and an evaluation precision of 6 ×10-16 is obtained at the average time of 300 000 s. In addition, a GPS common view instrument is set up to compare AFC with frequency standards at other time-keeping laboratories.\",\"PeriodicalId\":57667,\"journal\":{\"name\":\"时间频率公报\",\"volume\":\"15 1\",\"pages\":\"495-497\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"时间频率公报\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.1109/FCS.2015.7138892\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"时间频率公报","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/FCS.2015.7138892","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了上海光学精密机械研究所87Rb原子喷泉钟(AFC)的研究进展。我们直接锁定了AFC的本振(LO),并对物理系统进行了改进,包括优化微波耦合和降低询问区的工作温度等。将AFC与h脉泽进行比较,获得了2.7 × 10-13τ-1/2的短期分数频率稳定性。在AFC精度评价中,引入了一种自比较方法,在平均30万s的时间内获得了6 ×10-16的评价精度。此外,还建立了GPS共视仪,将AFC与其他计时实验室的频率标准进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Advances in the atomic fountain clock at SIOM
This work presents several advances in our 87Rb atomic fountain clock (AFC) at Shanghai Institute of Optics and Fine Mechanics (SIOM). We directly lock the local oscillator (LO) of AFC, and make some improvements on the physical system, including optimizing the coupling of microwave and adjusting down the working temperature of interrogation region, etc. A short-term fractional frequency stability of 2.7 × 10-13τ-1/2 is obtained by comparing the AFC with an H-maser. In accuracy evaluation of AFC, a self-comparison method is introduced, and an evaluation precision of 6 ×10-16 is obtained at the average time of 300 000 s. In addition, a GPS common view instrument is set up to compare AFC with frequency standards at other time-keeping laboratories.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
1135
期刊最新文献
Tutorial session Development of an erbium-fiber-laser-based optical frequency comb at NTSC 6/12-channel synchronous digital phasemeter for ultrastable signal characterization and use Research on time and frequency transfer based on BeiDou common view Preparing ACES-PHARAO data analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1