根据Ralph-Faylor对肝脏应用整骨疗法后血清氨浓度的变化

Leandro Alberto de Sousa PT, DO
{"title":"根据Ralph-Faylor对肝脏应用整骨疗法后血清氨浓度的变化","authors":"Leandro Alberto de Sousa PT, DO","doi":"10.1016/S1886-9297(11)70003-0","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>To demonstrate that Ralph Faylor's liver pumping technique does not reduce plasma ammonia levels in individuals with levels above 45<!--> <!-->μMol/L to levels considered normal.</p></div><div><h3>Patients, materials and methods</h3><p>We performed a single-blind randomized clinical trial in 31 patients with ammonia levels above 45<!--> <!-->μMol/L, divided in two groups. There were 16 patients in the treatment group and 15 in the control group. In both groups, ammonia levels were measured at five distinct time points: test 1, before the first intervention; test 2, within 7 to 10<!--> <!-->min after the first intervention; test 3, 24<!--> <!-->h after the first intervention; test 4, 7 days after the first intervention; and test 5, within 7 to 10<!--> <!-->min after the fourth intervention (one intervention per week) following the pre-established protocol.</p></div><div><h3>Results</h3><p>Statistical analysis revealed that the technique and/or its simulation produced no change in serum ammonia levels (P<!--> <!-->&gt;<!--> <!-->.05).</p></div><div><h3>Conclusion</h3><p>In patients with plasma ammonia levels above 45<!--> <!-->μMol/L, Ralph Failor's liver pumping technique cannot reduce blood concentrations of this metabolite.</p></div>","PeriodicalId":100997,"journal":{"name":"Osteopatía Científica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1886-9297(11)70003-0","citationCount":"0","resultStr":"{\"title\":\"Alteraciones en las concentraciones de amonio sérico después de la aplicación de la técnica osteopática sobre el hígado según Ralph-Faylor\",\"authors\":\"Leandro Alberto de Sousa PT, DO\",\"doi\":\"10.1016/S1886-9297(11)70003-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>To demonstrate that Ralph Faylor's liver pumping technique does not reduce plasma ammonia levels in individuals with levels above 45<!--> <!-->μMol/L to levels considered normal.</p></div><div><h3>Patients, materials and methods</h3><p>We performed a single-blind randomized clinical trial in 31 patients with ammonia levels above 45<!--> <!-->μMol/L, divided in two groups. There were 16 patients in the treatment group and 15 in the control group. In both groups, ammonia levels were measured at five distinct time points: test 1, before the first intervention; test 2, within 7 to 10<!--> <!-->min after the first intervention; test 3, 24<!--> <!-->h after the first intervention; test 4, 7 days after the first intervention; and test 5, within 7 to 10<!--> <!-->min after the fourth intervention (one intervention per week) following the pre-established protocol.</p></div><div><h3>Results</h3><p>Statistical analysis revealed that the technique and/or its simulation produced no change in serum ammonia levels (P<!--> <!-->&gt;<!--> <!-->.05).</p></div><div><h3>Conclusion</h3><p>In patients with plasma ammonia levels above 45<!--> <!-->μMol/L, Ralph Failor's liver pumping technique cannot reduce blood concentrations of this metabolite.</p></div>\",\"PeriodicalId\":100997,\"journal\":{\"name\":\"Osteopatía Científica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S1886-9297(11)70003-0\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Osteopatía Científica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1886929711700030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Osteopatía Científica","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1886929711700030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的证明Ralph Faylor肝泵技术不能使血浆氨浓度高于45 μMol/L的人降至正常水平。患者、材料和方法我们将31例氨浓度大于45 μMol/L的患者分为两组进行单盲随机临床试验。治疗组16例,对照组15例。在两组中,在五个不同的时间点测量氨水平:测试1,在第一次干预之前;试验2,在第一次干预后7 ~ 10分钟内;试验3,第一次干预后24 h;第一次干预后第4、7天;测试5,在按照预先制定的方案进行第四次干预(每周一次干预)后的7 - 10分钟内。结果统计分析显示,该技术和/或其模拟没有产生血清氨水平的变化(P >. 05)。结论在血浆氨浓度高于45 μMol/L的患者中,Ralph Failor肝泵送技术不能降低血氨浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Alteraciones en las concentraciones de amonio sérico después de la aplicación de la técnica osteopática sobre el hígado según Ralph-Faylor

Objective

To demonstrate that Ralph Faylor's liver pumping technique does not reduce plasma ammonia levels in individuals with levels above 45 μMol/L to levels considered normal.

Patients, materials and methods

We performed a single-blind randomized clinical trial in 31 patients with ammonia levels above 45 μMol/L, divided in two groups. There were 16 patients in the treatment group and 15 in the control group. In both groups, ammonia levels were measured at five distinct time points: test 1, before the first intervention; test 2, within 7 to 10 min after the first intervention; test 3, 24 h after the first intervention; test 4, 7 days after the first intervention; and test 5, within 7 to 10 min after the fourth intervention (one intervention per week) following the pre-established protocol.

Results

Statistical analysis revealed that the technique and/or its simulation produced no change in serum ammonia levels (P > .05).

Conclusion

In patients with plasma ammonia levels above 45 μMol/L, Ralph Failor's liver pumping technique cannot reduce blood concentrations of this metabolite.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Técnica articular para disfunción de malar en eversión Técnica de thrust occipitomastoidea Criterios de calidad en investigación osteopática (III) Efecto de las técnicas de articulación y manipulación sobre los apoyos plantares en el antepié varo infantil Revisión sistemática del tratamiento manipulativo para el hombro doloroso
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1