用于内燃机排气温度脉冲测量的细线热电偶设计

IF 1.1 Q3 TRANSPORTATION SCIENCE & TECHNOLOGY SAE International Journal of Engines Pub Date : 2023-05-17 DOI:10.4271/03-16-07-0055
Varun Venkataraman, O. Stenlaas, A. Cronhjort
{"title":"用于内燃机排气温度脉冲测量的细线热电偶设计","authors":"Varun Venkataraman, O. Stenlaas, A. Cronhjort","doi":"10.4271/03-16-07-0055","DOIUrl":null,"url":null,"abstract":"Accurate exhaust gas temperature (EGT) measurements are vital in the design and\n development process of internal combustion engines (ICEs). The unsteady ICE\n exhaust flow and thermal inertia of commonly used sheathed thermocouples and\n resistance thermometers require high bandwidth EGT pulse measurements for\n accurate cycle-resolved and mean EGTs. The EGT pulse measurement challenge is\n typically addressed using exposed thin-wire resistance thermometers or\n thermocouples. The sensor robustness to response tradeoff limits ICE tests to\n short durations over a few exhaust conditions. Larger diameter multiwire\n thermocouples using response compensation potentially overcomes the tradeoff.\n However, the literature commonly adopts weaker slack wire designs despite\n indications of coated weld taut wires being robust. This study experimentally\n evaluates the thin-wire thermocouple design placed in the exhaust of a\n heavy-duty diesel engine over wide-ranging exhaust conditions for improving both\n sensor robustness and accuracy of the measured EGT. The assessed design\n parameters included the wire diameter (51 μm to 254 μm), the exposed wire\n length, and the wires placed slack or taut with coated weld faces. All taut\n wires with ceramic-coated weld faces endured over 3 h of engine operation, while\n similar diameter slack wires (51 μm and 76 μm) were sensitive to the exhaust\n condition and exposed wire length. Reducing the wire diameter from 76 μm to 51\n μm significantly impacted response improvements as evidenced at certain test\n conditions by a peak-peak EGT increase of 92 °C, a mean EGT drop of 26 °C, and a\n doubling of the sensitivity of mean EGT cycle-to-cycle variations to ±12 °C.\n Increasing the exposed wire length showed less significant response\n improvements. The Type-K thin-wire thermocouples showed negligible drift,\n thereby indicating the possibility of using smaller and longer wires built taut\n with coated weld faces for improved accuracy of EGT measurements in ICEs.","PeriodicalId":47948,"journal":{"name":"SAE International Journal of Engines","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Thin-Wire Thermocouple Design for Exhaust Gas Temperature Pulse\\n Measurements in Internal Combustion Engines\",\"authors\":\"Varun Venkataraman, O. Stenlaas, A. Cronhjort\",\"doi\":\"10.4271/03-16-07-0055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate exhaust gas temperature (EGT) measurements are vital in the design and\\n development process of internal combustion engines (ICEs). The unsteady ICE\\n exhaust flow and thermal inertia of commonly used sheathed thermocouples and\\n resistance thermometers require high bandwidth EGT pulse measurements for\\n accurate cycle-resolved and mean EGTs. The EGT pulse measurement challenge is\\n typically addressed using exposed thin-wire resistance thermometers or\\n thermocouples. The sensor robustness to response tradeoff limits ICE tests to\\n short durations over a few exhaust conditions. Larger diameter multiwire\\n thermocouples using response compensation potentially overcomes the tradeoff.\\n However, the literature commonly adopts weaker slack wire designs despite\\n indications of coated weld taut wires being robust. This study experimentally\\n evaluates the thin-wire thermocouple design placed in the exhaust of a\\n heavy-duty diesel engine over wide-ranging exhaust conditions for improving both\\n sensor robustness and accuracy of the measured EGT. The assessed design\\n parameters included the wire diameter (51 μm to 254 μm), the exposed wire\\n length, and the wires placed slack or taut with coated weld faces. All taut\\n wires with ceramic-coated weld faces endured over 3 h of engine operation, while\\n similar diameter slack wires (51 μm and 76 μm) were sensitive to the exhaust\\n condition and exposed wire length. Reducing the wire diameter from 76 μm to 51\\n μm significantly impacted response improvements as evidenced at certain test\\n conditions by a peak-peak EGT increase of 92 °C, a mean EGT drop of 26 °C, and a\\n doubling of the sensitivity of mean EGT cycle-to-cycle variations to ±12 °C.\\n Increasing the exposed wire length showed less significant response\\n improvements. The Type-K thin-wire thermocouples showed negligible drift,\\n thereby indicating the possibility of using smaller and longer wires built taut\\n with coated weld faces for improved accuracy of EGT measurements in ICEs.\",\"PeriodicalId\":47948,\"journal\":{\"name\":\"SAE International Journal of Engines\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SAE International Journal of Engines\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4271/03-16-07-0055\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"TRANSPORTATION SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SAE International Journal of Engines","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4271/03-16-07-0055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"TRANSPORTATION SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

准确的废气温度测量在内燃机的设计和开发过程中至关重要。常用的护套热电偶和电阻温度计的非定常排气流量和热惯性需要高带宽的EGT脉冲测量,以获得精确的周期分辨和平均EGT。EGT脉冲测量挑战通常使用暴露的细丝电阻温度计或热电偶来解决。传感器对响应权衡的鲁棒性限制了内燃机测试在少数排气条件下的短持续时间。使用响应补偿的大直径多线热电偶可能会克服这种权衡。然而,文献通常采用较弱的松弛钢丝设计,尽管有迹象表明涂覆焊接绷紧钢丝是稳健的。本研究通过实验评估了重型柴油机排气中的细线热电偶设计,以提高传感器的鲁棒性和测量EGT的准确性。评估的设计参数包括线材直径(51 μm至254 μm)、外露线材长度以及线材在涂覆焊缝表面松弛或紧绷的情况。所有带有陶瓷涂层焊缝面的绷紧钢丝都能在发动机运行3小时以上,而类似直径的松弛钢丝(51 μm和76 μm)对排气条件和暴露钢丝长度敏感。在某些测试条件下,将线径从76 μm减小到51 μm可显著改善响应,峰值EGT增加92°C,平均EGT下降26°C,平均EGT周期变化的灵敏度增加一倍至±12°C。增加暴露导线长度对响应的改善不太显著。k型细线热电偶显示出可以忽略不计的漂移,从而表明可以使用更小、更长的钢丝,用涂覆的焊接面拉紧,以提高在ICEs中EGT测量的精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thin-Wire Thermocouple Design for Exhaust Gas Temperature Pulse Measurements in Internal Combustion Engines
Accurate exhaust gas temperature (EGT) measurements are vital in the design and development process of internal combustion engines (ICEs). The unsteady ICE exhaust flow and thermal inertia of commonly used sheathed thermocouples and resistance thermometers require high bandwidth EGT pulse measurements for accurate cycle-resolved and mean EGTs. The EGT pulse measurement challenge is typically addressed using exposed thin-wire resistance thermometers or thermocouples. The sensor robustness to response tradeoff limits ICE tests to short durations over a few exhaust conditions. Larger diameter multiwire thermocouples using response compensation potentially overcomes the tradeoff. However, the literature commonly adopts weaker slack wire designs despite indications of coated weld taut wires being robust. This study experimentally evaluates the thin-wire thermocouple design placed in the exhaust of a heavy-duty diesel engine over wide-ranging exhaust conditions for improving both sensor robustness and accuracy of the measured EGT. The assessed design parameters included the wire diameter (51 μm to 254 μm), the exposed wire length, and the wires placed slack or taut with coated weld faces. All taut wires with ceramic-coated weld faces endured over 3 h of engine operation, while similar diameter slack wires (51 μm and 76 μm) were sensitive to the exhaust condition and exposed wire length. Reducing the wire diameter from 76 μm to 51 μm significantly impacted response improvements as evidenced at certain test conditions by a peak-peak EGT increase of 92 °C, a mean EGT drop of 26 °C, and a doubling of the sensitivity of mean EGT cycle-to-cycle variations to ±12 °C. Increasing the exposed wire length showed less significant response improvements. The Type-K thin-wire thermocouples showed negligible drift, thereby indicating the possibility of using smaller and longer wires built taut with coated weld faces for improved accuracy of EGT measurements in ICEs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
SAE International Journal of Engines
SAE International Journal of Engines TRANSPORTATION SCIENCE & TECHNOLOGY-
CiteScore
2.70
自引率
8.30%
发文量
38
期刊最新文献
Combustion Mode Evaluation of a Methanol–Diesel Dual Direct Injection Engine with a Control of Injection Timing and Energy Substitution Ratio An Investigation on Exhaust Pulse Characteristics of Asymmetric Twin-Scroll Turbocharged Heavy-Duty Diesel Engine Optimizing Spark-Ignition Engine Performance with Ternary Blend Fuels and Hybrid Nanolubricants: A Response Surface Methodology Study Simulation Studies of Pollutant Emission from Passenger Cars Cavitation Phenomenon and Spray Atomization in Different Types of Diesel Engine Nozzles: A Systematic Review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1