废水中的磷分析:最佳实践白皮书

D. S. Smith
{"title":"废水中的磷分析:最佳实践白皮书","authors":"D. S. Smith","doi":"10.2166/9781780407807","DOIUrl":null,"url":null,"abstract":"Phosphorus (P) monitoring at wastewater treatment plants is essential as phosphorus (as total phosphorus) is an important main constituent regulated in treatment plant effluents. Recent trends are towards increasingly lower phosphorus limits, requiring reliable lower and lower phosphorus measurements. There is a long history of P analysis in dilute matrices; i.e., river and lake water and best practices have been developed. These best practices for surface waters are reported herein. Potential issues in wastewater P analysis by colorimetry include pH, proton to molybdenum ratio, color development time, and digestion method. Of equal importance are the QA/QC measurement protocols implemented by wastewater analysis labs; demonstrably well performing examples from Coeur d'Alene, Spokane, and the City of Las Vegas are presented. Total reactive phosphorus is an ambiguous analytical measurement because the quantitative results depend strongly on color development time. For low level analysis, long path lengths have advantages in more precisely resolving low concentrations. Replicate measurements are essential, especially for low level P samples, in order to capture the true value of the sample within variability. When dealing with low concentrations, even a small absolute error is a large relative error; thus, replicate measurements are essential to estimate true concentrations for dilute phosphorus samples.\n\nThis title belongs to WERF Research Report Series \n\nISBN: 9781780407807 (eBook)","PeriodicalId":23698,"journal":{"name":"Water intelligence online","volume":"1 1","pages":"9781780407807-9781780407807"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Phosphorus Analysis in Wastewater: Best Practices White Paper\",\"authors\":\"D. S. Smith\",\"doi\":\"10.2166/9781780407807\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Phosphorus (P) monitoring at wastewater treatment plants is essential as phosphorus (as total phosphorus) is an important main constituent regulated in treatment plant effluents. Recent trends are towards increasingly lower phosphorus limits, requiring reliable lower and lower phosphorus measurements. There is a long history of P analysis in dilute matrices; i.e., river and lake water and best practices have been developed. These best practices for surface waters are reported herein. Potential issues in wastewater P analysis by colorimetry include pH, proton to molybdenum ratio, color development time, and digestion method. Of equal importance are the QA/QC measurement protocols implemented by wastewater analysis labs; demonstrably well performing examples from Coeur d'Alene, Spokane, and the City of Las Vegas are presented. Total reactive phosphorus is an ambiguous analytical measurement because the quantitative results depend strongly on color development time. For low level analysis, long path lengths have advantages in more precisely resolving low concentrations. Replicate measurements are essential, especially for low level P samples, in order to capture the true value of the sample within variability. When dealing with low concentrations, even a small absolute error is a large relative error; thus, replicate measurements are essential to estimate true concentrations for dilute phosphorus samples.\\n\\nThis title belongs to WERF Research Report Series \\n\\nISBN: 9781780407807 (eBook)\",\"PeriodicalId\":23698,\"journal\":{\"name\":\"Water intelligence online\",\"volume\":\"1 1\",\"pages\":\"9781780407807-9781780407807\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water intelligence online\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/9781780407807\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water intelligence online","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/9781780407807","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在污水处理厂进行磷(P)监测是必不可少的,因为磷(因为总磷)是污水处理厂出水中重要的主要调节成分。最近的趋势是越来越低的磷限值,需要可靠的越来越低的磷测量。在稀矩阵中进行P分析已有很长的历史;也就是说,已经制定了河流和湖泊水以及最佳做法。这里报告了地表水的这些最佳做法。比色法分析废水中磷的潜在问题包括pH值、质子钼比、显色时间和消化方法。同样重要的是废水分析实验室实施的QA/QC测量协议;介绍了来自科达伦、斯波坎和拉斯维加斯市的明显表现良好的例子。总活性磷是一个模糊的分析测量,因为定量结果强烈依赖于显色时间。对于低浓度分析,长路径长度在更精确地解析低浓度方面具有优势。重复测量是必不可少的,特别是对于低水平的P样品,以便在可变性内捕获样品的真实值。在处理低浓度时,即使是很小的绝对误差也是很大的相对误差;因此,重复测量对于估计稀磷样品的真实浓度至关重要。本文属于WERF研究报告丛书ISBN: 9781780407807(电子书)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Phosphorus Analysis in Wastewater: Best Practices White Paper
Phosphorus (P) monitoring at wastewater treatment plants is essential as phosphorus (as total phosphorus) is an important main constituent regulated in treatment plant effluents. Recent trends are towards increasingly lower phosphorus limits, requiring reliable lower and lower phosphorus measurements. There is a long history of P analysis in dilute matrices; i.e., river and lake water and best practices have been developed. These best practices for surface waters are reported herein. Potential issues in wastewater P analysis by colorimetry include pH, proton to molybdenum ratio, color development time, and digestion method. Of equal importance are the QA/QC measurement protocols implemented by wastewater analysis labs; demonstrably well performing examples from Coeur d'Alene, Spokane, and the City of Las Vegas are presented. Total reactive phosphorus is an ambiguous analytical measurement because the quantitative results depend strongly on color development time. For low level analysis, long path lengths have advantages in more precisely resolving low concentrations. Replicate measurements are essential, especially for low level P samples, in order to capture the true value of the sample within variability. When dealing with low concentrations, even a small absolute error is a large relative error; thus, replicate measurements are essential to estimate true concentrations for dilute phosphorus samples. This title belongs to WERF Research Report Series ISBN: 9781780407807 (eBook)
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Integrated Water Resources Management in Water-scarce Regions: Water Harvesting, Groundwater Desalination and Water Reuse in Namibia Guide for Small Community Water Suppliers and Local Health Officials on Lead in Drinking Water Water Supply and Sanitation for All: Obligation of the water professionals for our common future: International Symposium September 27 - 28, 2007 Berching - Germany Trace element supplementation as a management tool for anaerobic digester operation: benefits and risks : eBook Phosphorus: Polluter and Resource of the Future - Removal and Recovery from Wastewater
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1