基于ELCB和MCB的非直接接触电压保护系统比较

S. Sunarto, Yoseph Santosa, S. Supriyanto
{"title":"基于ELCB和MCB的非直接接触电压保护系统比较","authors":"S. Sunarto, Yoseph Santosa, S. Supriyanto","doi":"10.31544/jtera.v7.i1.2022.83-90","DOIUrl":null,"url":null,"abstract":"Human safety against touch voltage hazards is the most important factor in electric power systems. Danger of touch voltage can occur if humans touch the live parts directly or indirectly. Indirect touch can occur when humans touch the open conductive parts (BKT) of equipment which under normal circumstances has no voltage but can be live due to leakage current due to damage to insulation in electrical cables. Therefore it is necessary to protect against indirect touch voltage. This study aims to analyze indirect touch voltage protection using Earth Leakage Circuit Breaker (ELCB) and Miniature Circuit Breaker (MCB). In this study, 30 mA ELCB and 2 A MCB were used as protection against indirect touch voltage hazards. The research data were obtained by using the experimental method, namely by conducting experiments in the laboratory. From the experimental results in the laboratory, it was found that the 30 mA ELCB is more sensitive as protection against indirect touch voltage than the MCB. This is because the working principle of the ELCB is based on the leakage current that occurs in the BKT, while the working principle of the MCB is based on the total current (leakage current and load current) flowing through the MCB.","PeriodicalId":17680,"journal":{"name":"JTERA (Jurnal Teknologi Rekayasa)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Analisis Perbandingan Sistem Proteksi Tegangan Sentuh Tidak Langsung Menggunakan ELCB dan MCB\",\"authors\":\"S. Sunarto, Yoseph Santosa, S. Supriyanto\",\"doi\":\"10.31544/jtera.v7.i1.2022.83-90\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Human safety against touch voltage hazards is the most important factor in electric power systems. Danger of touch voltage can occur if humans touch the live parts directly or indirectly. Indirect touch can occur when humans touch the open conductive parts (BKT) of equipment which under normal circumstances has no voltage but can be live due to leakage current due to damage to insulation in electrical cables. Therefore it is necessary to protect against indirect touch voltage. This study aims to analyze indirect touch voltage protection using Earth Leakage Circuit Breaker (ELCB) and Miniature Circuit Breaker (MCB). In this study, 30 mA ELCB and 2 A MCB were used as protection against indirect touch voltage hazards. The research data were obtained by using the experimental method, namely by conducting experiments in the laboratory. From the experimental results in the laboratory, it was found that the 30 mA ELCB is more sensitive as protection against indirect touch voltage than the MCB. This is because the working principle of the ELCB is based on the leakage current that occurs in the BKT, while the working principle of the MCB is based on the total current (leakage current and load current) flowing through the MCB.\",\"PeriodicalId\":17680,\"journal\":{\"name\":\"JTERA (Jurnal Teknologi Rekayasa)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JTERA (Jurnal Teknologi Rekayasa)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31544/jtera.v7.i1.2022.83-90\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JTERA (Jurnal Teknologi Rekayasa)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31544/jtera.v7.i1.2022.83-90","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在电力系统中,人体对接触电压危害的安全是最重要的因素。如果人类直接或间接接触带电部件,会产生接触电压的危险。当人类接触设备的开路导电部分(BKT)时,可能会发生间接接触,这些部分在正常情况下没有电压,但由于电缆绝缘损坏而产生泄漏电流,可能会带电。因此,有必要对间接接触电压进行保护。本研究旨在分析漏电断路器(ELCB)和微型断路器(MCB)的间接接触电压保护。在这项研究中,30 mA的ELCB和2a的MCB被用作间接接触电压危害的保护。研究数据是通过实验方法获得的,即在实验室进行实验。从实验室的实验结果来看,30ma ELCB对间接接触电压的保护比MCB更灵敏。这是因为ELCB的工作原理是基于BKT中发生的泄漏电流,而MCB的工作原理是基于流经MCB的总电流(泄漏电流和负载电流)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analisis Perbandingan Sistem Proteksi Tegangan Sentuh Tidak Langsung Menggunakan ELCB dan MCB
Human safety against touch voltage hazards is the most important factor in electric power systems. Danger of touch voltage can occur if humans touch the live parts directly or indirectly. Indirect touch can occur when humans touch the open conductive parts (BKT) of equipment which under normal circumstances has no voltage but can be live due to leakage current due to damage to insulation in electrical cables. Therefore it is necessary to protect against indirect touch voltage. This study aims to analyze indirect touch voltage protection using Earth Leakage Circuit Breaker (ELCB) and Miniature Circuit Breaker (MCB). In this study, 30 mA ELCB and 2 A MCB were used as protection against indirect touch voltage hazards. The research data were obtained by using the experimental method, namely by conducting experiments in the laboratory. From the experimental results in the laboratory, it was found that the 30 mA ELCB is more sensitive as protection against indirect touch voltage than the MCB. This is because the working principle of the ELCB is based on the leakage current that occurs in the BKT, while the working principle of the MCB is based on the total current (leakage current and load current) flowing through the MCB.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Implementasi Application Programmable Interface pada Sistem Manajemen Jaringan Berbasis Website Sistem Keamanan Gerbang Parkir Menggunakan Algoritma YOLO (You Only Look Once) dan Face Recognition Kendali Suhu Air Dengan Pengendali PI Menggunakan Metode Ziegler-Nichols I, Chien Servo I, dan Chien Regulator I Pengaruh Modulation Coding Scheme Terhadap Cakupan dan Kualitas Level Sinyal pada Jaringan 4G LTE Level Optimum Hyperparameter Tuning Epoch dalam Klasifikasi Citra Bencana Kebakaran
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1