反相高效液相色谱法测定复合维生素制剂中叶酸含量

A. Alekseeva, M. V. Gavrilin, T. B. Shemeryankina, M. S. Smirnova, E. P. Fedorova, T. Kargina, O. Novikov, S. Kovaleva, N. Boyko
{"title":"反相高效液相色谱法测定复合维生素制剂中叶酸含量","authors":"A. Alekseeva, M. V. Gavrilin, T. B. Shemeryankina, M. S. Smirnova, E. P. Fedorova, T. Kargina, O. Novikov, S. Kovaleva, N. Boyko","doi":"10.30895/1991-2919-2021-11-2-185-192","DOIUrl":null,"url":null,"abstract":"A great variety of components in multivitamin preparations containing folic acid, and a variety of test methods and conditions of folic acid determination proposed by manufacturers, require alignment of test procedures for products with similar composition.The aim of the study was to compare the results of experimental verification of folic acid determination procedures which use reversed phase high-performance liquid chromatography (RP HPLC) with isocratic elution mode. Materials and methods: The Agilent 1260 Infinity II LC system with a diode array detector (280 nm), isocratic elution mode, C8- and C18-bonded silica gel chromatographic columns, model mixtures containing folic acid, cyanocobalamin, ferrous sulfate, and potassium iodide, were used in the study.Results: The lowest relative standard deviation of the folic acid peak area (RSD=0.09%), and the lowest asymmetry factor (As=1.04) for folic acid were observed for the model mixture “ferrous sulfate+folic acid+cyanocobalamin” and the following test conditions. Column: 250×4.0 mm, silica gel for chromatography, octylsilyl (C8), endcapped; mobile phase:  methanol‒phosphate buffer (12:88), pH 6.6; column temperature: 25ºС. The study demonstrated the feasibility of using these conditions for determination of pteroic acid impurity with simultaneous precipitation of interfering ferrous ions, using ethylenediaminetetraacetic acid solution, pH 9.5, as a solvent.Conclusions: RP HPLC can be recommended as an optimal aligned test procedure for determination of folic acid in combination products. It is recommended to use a solution containing folic and pteroic acids for system suitability testing.","PeriodicalId":22286,"journal":{"name":"The Bulletin of the Scientific Centre for Expert Evaluation of Medicinal Products","volume":"55 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of Folic Acid in Multivitamin Preparations by Reversed Phase HPLC\",\"authors\":\"A. Alekseeva, M. V. Gavrilin, T. B. Shemeryankina, M. S. Smirnova, E. P. Fedorova, T. Kargina, O. Novikov, S. Kovaleva, N. Boyko\",\"doi\":\"10.30895/1991-2919-2021-11-2-185-192\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A great variety of components in multivitamin preparations containing folic acid, and a variety of test methods and conditions of folic acid determination proposed by manufacturers, require alignment of test procedures for products with similar composition.The aim of the study was to compare the results of experimental verification of folic acid determination procedures which use reversed phase high-performance liquid chromatography (RP HPLC) with isocratic elution mode. Materials and methods: The Agilent 1260 Infinity II LC system with a diode array detector (280 nm), isocratic elution mode, C8- and C18-bonded silica gel chromatographic columns, model mixtures containing folic acid, cyanocobalamin, ferrous sulfate, and potassium iodide, were used in the study.Results: The lowest relative standard deviation of the folic acid peak area (RSD=0.09%), and the lowest asymmetry factor (As=1.04) for folic acid were observed for the model mixture “ferrous sulfate+folic acid+cyanocobalamin” and the following test conditions. Column: 250×4.0 mm, silica gel for chromatography, octylsilyl (C8), endcapped; mobile phase:  methanol‒phosphate buffer (12:88), pH 6.6; column temperature: 25ºС. The study demonstrated the feasibility of using these conditions for determination of pteroic acid impurity with simultaneous precipitation of interfering ferrous ions, using ethylenediaminetetraacetic acid solution, pH 9.5, as a solvent.Conclusions: RP HPLC can be recommended as an optimal aligned test procedure for determination of folic acid in combination products. It is recommended to use a solution containing folic and pteroic acids for system suitability testing.\",\"PeriodicalId\":22286,\"journal\":{\"name\":\"The Bulletin of the Scientific Centre for Expert Evaluation of Medicinal Products\",\"volume\":\"55 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Bulletin of the Scientific Centre for Expert Evaluation of Medicinal Products\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30895/1991-2919-2021-11-2-185-192\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Bulletin of the Scientific Centre for Expert Evaluation of Medicinal Products","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30895/1991-2919-2021-11-2-185-192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

含有叶酸的多种维生素制剂中的多种成分,以及制造商提出的多种测定叶酸的测试方法和条件,需要对具有相似成分的产品的测试程序进行校准。本研究的目的是比较反相高效液相色谱法(RP - HPLC)测定叶酸方法的实验验证结果。材料和方法:采用Agilent 1260 Infinity II液相色谱系统,二极管阵列检测器(280 nm),等压洗脱模式,C8-和c18键合硅胶色谱柱,含有叶酸、氰钴胺素、硫酸亚铁和碘化钾的模型混合物。结果:在“硫酸亚铁+叶酸+氰钴胺素”模型混合物和以下试验条件下,叶酸峰面积的相对标准偏差最小(RSD=0.09%),不对称因子最小(As=1.04)。色谱柱:250×4.0 mm,硅胶用于色谱,辛基硅基(C8),端盖;流动相:甲醇-磷酸盐缓冲液(12:88),pH 6.6;柱温:25ºС。研究表明,以pH为9.5的乙二胺四乙酸溶液为溶剂,利用上述条件同时沉淀干扰性亚铁离子测定紫菜酸杂质是可行的。结论:RP - HPLC法可作为复方制剂中叶酸含量测定的最佳方法。建议使用含有叶酸和翼元酸的溶液进行系统适用性测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of Folic Acid in Multivitamin Preparations by Reversed Phase HPLC
A great variety of components in multivitamin preparations containing folic acid, and a variety of test methods and conditions of folic acid determination proposed by manufacturers, require alignment of test procedures for products with similar composition.The aim of the study was to compare the results of experimental verification of folic acid determination procedures which use reversed phase high-performance liquid chromatography (RP HPLC) with isocratic elution mode. Materials and methods: The Agilent 1260 Infinity II LC system with a diode array detector (280 nm), isocratic elution mode, C8- and C18-bonded silica gel chromatographic columns, model mixtures containing folic acid, cyanocobalamin, ferrous sulfate, and potassium iodide, were used in the study.Results: The lowest relative standard deviation of the folic acid peak area (RSD=0.09%), and the lowest asymmetry factor (As=1.04) for folic acid were observed for the model mixture “ferrous sulfate+folic acid+cyanocobalamin” and the following test conditions. Column: 250×4.0 mm, silica gel for chromatography, octylsilyl (C8), endcapped; mobile phase:  methanol‒phosphate buffer (12:88), pH 6.6; column temperature: 25ºС. The study demonstrated the feasibility of using these conditions for determination of pteroic acid impurity with simultaneous precipitation of interfering ferrous ions, using ethylenediaminetetraacetic acid solution, pH 9.5, as a solvent.Conclusions: RP HPLC can be recommended as an optimal aligned test procedure for determination of folic acid in combination products. It is recommended to use a solution containing folic and pteroic acids for system suitability testing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of the Medicinal Products for Human Use Authorised in the Russian Federation Diffusion-Ordered NMR Spectroscopy Application for Analysis of Polysaccharides Determination of Heavy Metals, Arsenic, and Aluminum Content in Pumpkin Seed Herbal Substance and Native Products, by Inductively Coupled Plasma Mass Spectrometry The Use of Spectroscopic Methods for Structural Elucidation of Individual Secondary Metabolites Isolated from the Aerial Parts of Corydalis bracteata NMR as Used in the Russian and Foreign Pharmacopoeias for Quality Control of Medicinal Products
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1