W. Olson, D. Peterson, L. Ruetz, B. Gunderson, M.C. Fang-Yen
{"title":"植入式起搏器-心律转复-除颤器快速室性心动过速与室颤和慢速室性心动过速的区别","authors":"W. Olson, D. Peterson, L. Ruetz, B. Gunderson, M.C. Fang-Yen","doi":"10.1109/CIC.1993.378355","DOIUrl":null,"url":null,"abstract":"Implantable Pacer-Cardioverter-Defibrillators (PCD) sense ventricular electrograms from epicardial or endocardial leads with an auto-adjusting threshold and analyze a recent series of cycle lengths with algorithms to detect ventricular tachycardia (VT) and ventricular fibrillation (VF) for tiered therapies. A new algorithm to detect fast ventricular tachycardia (FVT) in a zone between VT and VF either via VT-type counting or via VF-type counting is described. Gaussian strings of cycle lengths with uniformly distributed means and standard deviations and databases of human tachyarrhythmias are analyzed. Detection algorithm sensitivity, specificity with 95% confidence intervals and the predictive value of a positive test for VF (PVP) are studied as a function of programmable defection parameters. While maintaining 100% VF sensitivity, VF specificity is increased by 20% for FVT via VF thereby safely reducing the number of painful shocks.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"21 1","pages":"835-838"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Discrimination of fast ventricular tachycardia from ventricular fibrillation and slow ventricular tachycardia for an implantable pacer-cardioverter-defibrillator\",\"authors\":\"W. Olson, D. Peterson, L. Ruetz, B. Gunderson, M.C. Fang-Yen\",\"doi\":\"10.1109/CIC.1993.378355\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Implantable Pacer-Cardioverter-Defibrillators (PCD) sense ventricular electrograms from epicardial or endocardial leads with an auto-adjusting threshold and analyze a recent series of cycle lengths with algorithms to detect ventricular tachycardia (VT) and ventricular fibrillation (VF) for tiered therapies. A new algorithm to detect fast ventricular tachycardia (FVT) in a zone between VT and VF either via VT-type counting or via VF-type counting is described. Gaussian strings of cycle lengths with uniformly distributed means and standard deviations and databases of human tachyarrhythmias are analyzed. Detection algorithm sensitivity, specificity with 95% confidence intervals and the predictive value of a positive test for VF (PVP) are studied as a function of programmable defection parameters. While maintaining 100% VF sensitivity, VF specificity is increased by 20% for FVT via VF thereby safely reducing the number of painful shocks.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"21 1\",\"pages\":\"835-838\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378355\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378355","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Discrimination of fast ventricular tachycardia from ventricular fibrillation and slow ventricular tachycardia for an implantable pacer-cardioverter-defibrillator
Implantable Pacer-Cardioverter-Defibrillators (PCD) sense ventricular electrograms from epicardial or endocardial leads with an auto-adjusting threshold and analyze a recent series of cycle lengths with algorithms to detect ventricular tachycardia (VT) and ventricular fibrillation (VF) for tiered therapies. A new algorithm to detect fast ventricular tachycardia (FVT) in a zone between VT and VF either via VT-type counting or via VF-type counting is described. Gaussian strings of cycle lengths with uniformly distributed means and standard deviations and databases of human tachyarrhythmias are analyzed. Detection algorithm sensitivity, specificity with 95% confidence intervals and the predictive value of a positive test for VF (PVP) are studied as a function of programmable defection parameters. While maintaining 100% VF sensitivity, VF specificity is increased by 20% for FVT via VF thereby safely reducing the number of painful shocks.<>