{"title":"400 MHz双排MRI阵列的几何结构优化","authors":"M. Kozlov, R. Turner","doi":"10.1109/IMWS-BIO.2013.6756173","DOIUrl":null,"url":null,"abstract":"We numerically investigated several magnetic resonance imaging radiofrequency transmit coil arrays, with and without a local shield, and with a range of scanner bore configurations. The latter had a significant influence on safety excitation efficiency. It is therefore important to include the scanner magnet room in the simulation domain, when the scanner bore is not isolated from the rest of the scan room by an electric shield or RF absorber. All arrays investigated provided similar inhomogeneity over the entire brain for a given excitation condition. However, for CP excitation mode transmit excitation efficiency was found to be higher for an array without a local shield.","PeriodicalId":6321,"journal":{"name":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","volume":"66 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Optimization of geometry for a dual-row MRI array at 400 MHz\",\"authors\":\"M. Kozlov, R. Turner\",\"doi\":\"10.1109/IMWS-BIO.2013.6756173\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We numerically investigated several magnetic resonance imaging radiofrequency transmit coil arrays, with and without a local shield, and with a range of scanner bore configurations. The latter had a significant influence on safety excitation efficiency. It is therefore important to include the scanner magnet room in the simulation domain, when the scanner bore is not isolated from the rest of the scan room by an electric shield or RF absorber. All arrays investigated provided similar inhomogeneity over the entire brain for a given excitation condition. However, for CP excitation mode transmit excitation efficiency was found to be higher for an array without a local shield.\",\"PeriodicalId\":6321,\"journal\":{\"name\":\"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)\",\"volume\":\"66 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMWS-BIO.2013.6756173\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMWS-BIO.2013.6756173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

我们对几种磁共振成像射频发射线圈阵列进行了数值研究,包括带和不带局部屏蔽,以及一系列扫描孔配置。后者对安全激励效率有显著影响。因此,当扫描孔没有通过电屏蔽或射频吸收器与扫描室的其余部分隔离时,将扫描仪磁室包括在仿真域中是很重要的。在给定的激发条件下,所有被调查的阵列在整个大脑中都提供了类似的不均匀性。然而,对于CP激励模式,没有局部屏蔽的阵列的发射激励效率更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of geometry for a dual-row MRI array at 400 MHz
We numerically investigated several magnetic resonance imaging radiofrequency transmit coil arrays, with and without a local shield, and with a range of scanner bore configurations. The latter had a significant influence on safety excitation efficiency. It is therefore important to include the scanner magnet room in the simulation domain, when the scanner bore is not isolated from the rest of the scan room by an electric shield or RF absorber. All arrays investigated provided similar inhomogeneity over the entire brain for a given excitation condition. However, for CP excitation mode transmit excitation efficiency was found to be higher for an array without a local shield.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Technical program committee Organizing committee Fast, compact and label-free electrical detection of live and dead single cells Why headache using GSM cellular phones? An investigation of microwave ablation for bone thermal drilling
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1