Roel Langshong, B. Punithavasanthan, Pheiroijam Bhupes, S. Singh, Rajkumar Debbarma, P. S. Prashanth, P. rai, Shams Gulrez, Dilip Soring, Temjen sunep
{"title":"对侧股骨远端锁定加压钢板固定粗隆下骨折","authors":"Roel Langshong, B. Punithavasanthan, Pheiroijam Bhupes, S. Singh, Rajkumar Debbarma, P. S. Prashanth, P. rai, Shams Gulrez, Dilip Soring, Temjen sunep","doi":"10.9790/0853-1607013945","DOIUrl":null,"url":null,"abstract":"Introduction: Different implants are available to internally fix subtrochantric fracture of femur, due to anatomical & biomechanical reasons, the sub-trochanteric femoral fracture still a challenge for Orthopaedic Surgeons Objective: The purpose of this study was to evaluate the outcome in early treatment of subtrochanteric fractures of femur with distal femoral locking compression plate of contralateral side. Methods: Thirty patients were included in this study. Sixteen patients (53.3%) had AO type 32B fracture, while nine patients (30%) and five patients (16.6%) were classified as AO type 32A and 32C respectively. Road traffic accidents accounted for 21 patients (70%). Mean follow-ups were 11 ±6 months (range 6 to 19 months). 27 fractures (90%) achieved union, average union time in 14.5 weeks Ranging from 10 weeks to 20 weeks. while three patients (10%) had complications. In one patient the plate had broken, one had broken screw and nonunion of the fracture. At the end of the follow-ups, 29 patients (96.6%) were community ambulators.The Modified Harris hip score (MMHS) was used to evaluate the functional outcome of surgery Conclusion: We conclude that distal femoral locking compression plate of contra lateral side is as effective as PF-LCP and is an effective alternative treatment for subtrochanteric fractures when properly performed.","PeriodicalId":14489,"journal":{"name":"IOSR Journal of Dental and Medical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fixation of Subtrochantric Fractures Using Distal Femoral Locking Compression Plate of Contralateral Side\",\"authors\":\"Roel Langshong, B. Punithavasanthan, Pheiroijam Bhupes, S. Singh, Rajkumar Debbarma, P. S. Prashanth, P. rai, Shams Gulrez, Dilip Soring, Temjen sunep\",\"doi\":\"10.9790/0853-1607013945\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Different implants are available to internally fix subtrochantric fracture of femur, due to anatomical & biomechanical reasons, the sub-trochanteric femoral fracture still a challenge for Orthopaedic Surgeons Objective: The purpose of this study was to evaluate the outcome in early treatment of subtrochanteric fractures of femur with distal femoral locking compression plate of contralateral side. Methods: Thirty patients were included in this study. Sixteen patients (53.3%) had AO type 32B fracture, while nine patients (30%) and five patients (16.6%) were classified as AO type 32A and 32C respectively. Road traffic accidents accounted for 21 patients (70%). Mean follow-ups were 11 ±6 months (range 6 to 19 months). 27 fractures (90%) achieved union, average union time in 14.5 weeks Ranging from 10 weeks to 20 weeks. while three patients (10%) had complications. In one patient the plate had broken, one had broken screw and nonunion of the fracture. At the end of the follow-ups, 29 patients (96.6%) were community ambulators.The Modified Harris hip score (MMHS) was used to evaluate the functional outcome of surgery Conclusion: We conclude that distal femoral locking compression plate of contra lateral side is as effective as PF-LCP and is an effective alternative treatment for subtrochanteric fractures when properly performed.\",\"PeriodicalId\":14489,\"journal\":{\"name\":\"IOSR Journal of Dental and Medical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IOSR Journal of Dental and Medical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9790/0853-1607013945\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IOSR Journal of Dental and Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9790/0853-1607013945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fixation of Subtrochantric Fractures Using Distal Femoral Locking Compression Plate of Contralateral Side
Introduction: Different implants are available to internally fix subtrochantric fracture of femur, due to anatomical & biomechanical reasons, the sub-trochanteric femoral fracture still a challenge for Orthopaedic Surgeons Objective: The purpose of this study was to evaluate the outcome in early treatment of subtrochanteric fractures of femur with distal femoral locking compression plate of contralateral side. Methods: Thirty patients were included in this study. Sixteen patients (53.3%) had AO type 32B fracture, while nine patients (30%) and five patients (16.6%) were classified as AO type 32A and 32C respectively. Road traffic accidents accounted for 21 patients (70%). Mean follow-ups were 11 ±6 months (range 6 to 19 months). 27 fractures (90%) achieved union, average union time in 14.5 weeks Ranging from 10 weeks to 20 weeks. while three patients (10%) had complications. In one patient the plate had broken, one had broken screw and nonunion of the fracture. At the end of the follow-ups, 29 patients (96.6%) were community ambulators.The Modified Harris hip score (MMHS) was used to evaluate the functional outcome of surgery Conclusion: We conclude that distal femoral locking compression plate of contra lateral side is as effective as PF-LCP and is an effective alternative treatment for subtrochanteric fractures when properly performed.