一种降低标准心电图信号重叠噪声的新方法

D. Wei, E. Harasawa, H. Harada, H. Hosaka
{"title":"一种降低标准心电图信号重叠噪声的新方法","authors":"D. Wei, E. Harasawa, H. Harada, H. Hosaka","doi":"10.1109/CIC.1993.378365","DOIUrl":null,"url":null,"abstract":"A new method is developed for reducing signal-overlapping noise in the standard electrocardiogram, which has so far been difficult with a traditional filter based on the frequency method. The new method, called signal decomposition method, first separates the input signal into a noise-free part and a noise-overlapping part with a zero-phase low-pass filter. It then restores the signal components from the noise-overlapping part and adds the signal components to the noise-free part so as to eliminate distortion of the original signal. An experimental study with clinical ECG data shows that this method is very effective in reducing signal-overlapping noise and power interference, with little signal distortion.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"48 1","pages":"795-798"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A new method for reducing signal-overlapping noise in standard electrocardiogram\",\"authors\":\"D. Wei, E. Harasawa, H. Harada, H. Hosaka\",\"doi\":\"10.1109/CIC.1993.378365\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new method is developed for reducing signal-overlapping noise in the standard electrocardiogram, which has so far been difficult with a traditional filter based on the frequency method. The new method, called signal decomposition method, first separates the input signal into a noise-free part and a noise-overlapping part with a zero-phase low-pass filter. It then restores the signal components from the noise-overlapping part and adds the signal components to the noise-free part so as to eliminate distortion of the original signal. An experimental study with clinical ECG data shows that this method is very effective in reducing signal-overlapping noise and power interference, with little signal distortion.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"48 1\",\"pages\":\"795-798\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378365\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种新的方法来降低标准心电图中的信号重叠噪声,这是传统的基于频率法的滤波器难以做到的。该方法首先利用零相低通滤波器将输入信号分离为无噪声部分和有噪声重叠部分。然后从噪声重叠部分恢复信号分量,并将信号分量加到无噪声部分,从而消除原始信号的失真。对临床心电数据的实验研究表明,该方法能有效地降低信号重叠噪声和功率干扰,且信号失真小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A new method for reducing signal-overlapping noise in standard electrocardiogram
A new method is developed for reducing signal-overlapping noise in the standard electrocardiogram, which has so far been difficult with a traditional filter based on the frequency method. The new method, called signal decomposition method, first separates the input signal into a noise-free part and a noise-overlapping part with a zero-phase low-pass filter. It then restores the signal components from the noise-overlapping part and adds the signal components to the noise-free part so as to eliminate distortion of the original signal. An experimental study with clinical ECG data shows that this method is very effective in reducing signal-overlapping noise and power interference, with little signal distortion.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A 528 channel system for the acquisition and display of defibrillation and electrocardiographic potentials Computers: the heart of screening Signal averaging enhancement by jitter deconvolution Numerical simulation of the flow in model skeletal muscle ventricles Transmembrane potential changes during stimulation in a bidomain model of the myocardium
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1