Panrawee Kanpan, E. Khansalee, N. Puangngernmak, S. Chalermwisutkul
{"title":"TM010型圆柱腔用于液体复介电常数测量的场分析技术","authors":"Panrawee Kanpan, E. Khansalee, N. Puangngernmak, S. Chalermwisutkul","doi":"10.1109/ECTICON.2012.6254274","DOIUrl":null,"url":null,"abstract":"A 3 GHz TM010 mode cylindrical cavity resonator was designed for measuring complex permittivity of liquid material. To improve the measurement accuracy of cavity perturbation method which occurs from variable size of the samples, the field analysis of TM0n0 cylindrical cavities with two concentric layers of real dielectric at the axis is used. The field analysis method was proposed for calculation of the complex permittivity for liquid material by using the resonant technique. The complex permittivities of distilled water, methanol and ethanol samples were measured. Measured complex permittivity results were compared with the ones acquired by the conventional perturbation method.","PeriodicalId":6319,"journal":{"name":"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","volume":"1 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"TM010 mode cylindrical cavity for complex permittivity measurement of liquid using field analysis technique\",\"authors\":\"Panrawee Kanpan, E. Khansalee, N. Puangngernmak, S. Chalermwisutkul\",\"doi\":\"10.1109/ECTICON.2012.6254274\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 3 GHz TM010 mode cylindrical cavity resonator was designed for measuring complex permittivity of liquid material. To improve the measurement accuracy of cavity perturbation method which occurs from variable size of the samples, the field analysis of TM0n0 cylindrical cavities with two concentric layers of real dielectric at the axis is used. The field analysis method was proposed for calculation of the complex permittivity for liquid material by using the resonant technique. The complex permittivities of distilled water, methanol and ethanol samples were measured. Measured complex permittivity results were compared with the ones acquired by the conventional perturbation method.\",\"PeriodicalId\":6319,\"journal\":{\"name\":\"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology\",\"volume\":\"1 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECTICON.2012.6254274\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTICON.2012.6254274","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
TM010 mode cylindrical cavity for complex permittivity measurement of liquid using field analysis technique
A 3 GHz TM010 mode cylindrical cavity resonator was designed for measuring complex permittivity of liquid material. To improve the measurement accuracy of cavity perturbation method which occurs from variable size of the samples, the field analysis of TM0n0 cylindrical cavities with two concentric layers of real dielectric at the axis is used. The field analysis method was proposed for calculation of the complex permittivity for liquid material by using the resonant technique. The complex permittivities of distilled water, methanol and ethanol samples were measured. Measured complex permittivity results were compared with the ones acquired by the conventional perturbation method.