Ankita Aggarwal, Zubair Khan, Christian Machado, Marcel Zughaib
{"title":"评估慢性收缩期心力衰竭患者胸阻抗与远程监测肺动脉压的相关性。","authors":"Ankita Aggarwal, Zubair Khan, Christian Machado, Marcel Zughaib","doi":"10.14740/cr1447","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Heart failure (HF) readmission continues to be a major health problem. Monitoring pulmonary artery pressure (PAP) and thoracic impedance (TI) are the two modalities utilized for early identification of decompensation in HF patients. We aimed to assess the correlation between these two modalities in patients who simultaneously had both the devices.</p><p><strong>Methods: </strong>Patients with history of New York Heart Association class III systolic HF with a pre-implanted intracardiac defibrillator (ICD) capable of monitoring TI and pre-implanted CardioMEMs™ remote HF monitoring device were included. Hemodynamic data including TI and PAPs were measured at baseline and then weekly. Weekly percentage change was then calculated as: Weekly percentage change = (week 2 - week1)/week 1 × 100. Variability between the methods was expressed by Bland-Altman analysis. Significance was determined as a P-value < 0.05.</p><p><strong>Results: </strong>Nine patients met the inclusion criteria. There was no significant correlation between the assessed weekly percentage changes in pulmonary artery diastolic pressure (PAdP) and TI measurements (r = -0.180, P = 0.065). Using Bland-Altman analytic methods, both methods had no significant difference in agreement (0.011±0.094%, P = 0.215). With the linear regression model applied for Bland-Altman analysis, the two methods appeared to have proportional bias without agreement (unstandardized beta-coefficient of 1.91, t 22.9, P ≤ 0.001).</p><p><strong>Conclusion: </strong>Our study demonstrated that variations exist between measurement of PAdP and TI; however, there is no significant correlation between weekly variations between them.</p>","PeriodicalId":9424,"journal":{"name":"Cardiology Research","volume":"14 1","pages":"32-37"},"PeriodicalIF":1.4000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/28/11/cr-14-032.PMC9990537.pdf","citationCount":"0","resultStr":"{\"title\":\"Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure.\",\"authors\":\"Ankita Aggarwal, Zubair Khan, Christian Machado, Marcel Zughaib\",\"doi\":\"10.14740/cr1447\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Heart failure (HF) readmission continues to be a major health problem. Monitoring pulmonary artery pressure (PAP) and thoracic impedance (TI) are the two modalities utilized for early identification of decompensation in HF patients. We aimed to assess the correlation between these two modalities in patients who simultaneously had both the devices.</p><p><strong>Methods: </strong>Patients with history of New York Heart Association class III systolic HF with a pre-implanted intracardiac defibrillator (ICD) capable of monitoring TI and pre-implanted CardioMEMs™ remote HF monitoring device were included. Hemodynamic data including TI and PAPs were measured at baseline and then weekly. Weekly percentage change was then calculated as: Weekly percentage change = (week 2 - week1)/week 1 × 100. Variability between the methods was expressed by Bland-Altman analysis. Significance was determined as a P-value < 0.05.</p><p><strong>Results: </strong>Nine patients met the inclusion criteria. There was no significant correlation between the assessed weekly percentage changes in pulmonary artery diastolic pressure (PAdP) and TI measurements (r = -0.180, P = 0.065). Using Bland-Altman analytic methods, both methods had no significant difference in agreement (0.011±0.094%, P = 0.215). With the linear regression model applied for Bland-Altman analysis, the two methods appeared to have proportional bias without agreement (unstandardized beta-coefficient of 1.91, t 22.9, P ≤ 0.001).</p><p><strong>Conclusion: </strong>Our study demonstrated that variations exist between measurement of PAdP and TI; however, there is no significant correlation between weekly variations between them.</p>\",\"PeriodicalId\":9424,\"journal\":{\"name\":\"Cardiology Research\",\"volume\":\"14 1\",\"pages\":\"32-37\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/28/11/cr-14-032.PMC9990537.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14740/cr1447\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14740/cr1447","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure.
Background: Heart failure (HF) readmission continues to be a major health problem. Monitoring pulmonary artery pressure (PAP) and thoracic impedance (TI) are the two modalities utilized for early identification of decompensation in HF patients. We aimed to assess the correlation between these two modalities in patients who simultaneously had both the devices.
Methods: Patients with history of New York Heart Association class III systolic HF with a pre-implanted intracardiac defibrillator (ICD) capable of monitoring TI and pre-implanted CardioMEMs™ remote HF monitoring device were included. Hemodynamic data including TI and PAPs were measured at baseline and then weekly. Weekly percentage change was then calculated as: Weekly percentage change = (week 2 - week1)/week 1 × 100. Variability between the methods was expressed by Bland-Altman analysis. Significance was determined as a P-value < 0.05.
Results: Nine patients met the inclusion criteria. There was no significant correlation between the assessed weekly percentage changes in pulmonary artery diastolic pressure (PAdP) and TI measurements (r = -0.180, P = 0.065). Using Bland-Altman analytic methods, both methods had no significant difference in agreement (0.011±0.094%, P = 0.215). With the linear regression model applied for Bland-Altman analysis, the two methods appeared to have proportional bias without agreement (unstandardized beta-coefficient of 1.91, t 22.9, P ≤ 0.001).
Conclusion: Our study demonstrated that variations exist between measurement of PAdP and TI; however, there is no significant correlation between weekly variations between them.
期刊介绍:
Cardiology Research is an open access, peer-reviewed, international journal. All submissions relating to basic research and clinical practice of cardiology and cardiovascular medicine are in this journal''s scope. This journal focuses on publishing original research and observations in all cardiovascular medicine aspects. Manuscript types include original article, review, case report, short communication, book review, letter to the editor.