{"title":"不同表面处理对骨水泥固位种植冠固位的影响","authors":"Esra Bilgi Ozyetim, Zeynep Ozdemir, Gül Bahar Basim, Gülsen Bayraktar","doi":"10.11607/ijp.6602","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of different treatments applied to titanium implant abutment surfaces on the retention of implant-supported cement-retained crowns using resin cement.</p><p><strong>Materials and methods: </strong>A total of 72 titanium implant abutments were divided into six groups (n = 12 each) based on the selected surface treatments: (1) untreated; (2) airborne particle abrasion; (3) hydrogen peroxide etching; (4) atmospheric plasma; (5) chemical mechanical polishing; and (6) titanium dioxide (TiO<sub>2</sub>) nano coating. After the surface treatments, scanning electron microscopy analyses and surface roughness measurements of the abutment surfaces were performed. Seventy-two metal copings were fabricated and cemented on the abutments with dual-curing resin cement. After a thermal cycling process, crown retention was measured using a universal testing machine. The experimental results were statistically evaluated with one-way analysis of variance, Tukey honest significant difference, and Tamhane's T2 tests.</p><p><strong>Results: </strong>The highest surface roughness values were obtained with the airborne-particle abrasion group (1.44 μm), which also resulted in the highest retention values (828.5 N), followed by the hydrogen peroxide-etching group (490.7 N), the atmospheric plasma group (466.5 N), the chemical mechanical polishing group (410.8 N), and the control group (382.6 N).</p><p><strong>Conclusion: </strong>It was determined that airborne particle abrasion, hydrogen peroxide etching, and atmospheric plasma treatments significantly increased the crown retention and that all alternative treatments, except for TiO<sub>2</sub> nano coating, worked better than the untreated control.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 1","pages":"49–58"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of Different Surface Treatments on Retention of Cement-Retained, Implant-Supported Crowns\",\"authors\":\"Esra Bilgi Ozyetim, Zeynep Ozdemir, Gül Bahar Basim, Gülsen Bayraktar\",\"doi\":\"10.11607/ijp.6602\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the effect of different treatments applied to titanium implant abutment surfaces on the retention of implant-supported cement-retained crowns using resin cement.</p><p><strong>Materials and methods: </strong>A total of 72 titanium implant abutments were divided into six groups (n = 12 each) based on the selected surface treatments: (1) untreated; (2) airborne particle abrasion; (3) hydrogen peroxide etching; (4) atmospheric plasma; (5) chemical mechanical polishing; and (6) titanium dioxide (TiO<sub>2</sub>) nano coating. After the surface treatments, scanning electron microscopy analyses and surface roughness measurements of the abutment surfaces were performed. Seventy-two metal copings were fabricated and cemented on the abutments with dual-curing resin cement. After a thermal cycling process, crown retention was measured using a universal testing machine. The experimental results were statistically evaluated with one-way analysis of variance, Tukey honest significant difference, and Tamhane's T2 tests.</p><p><strong>Results: </strong>The highest surface roughness values were obtained with the airborne-particle abrasion group (1.44 μm), which also resulted in the highest retention values (828.5 N), followed by the hydrogen peroxide-etching group (490.7 N), the atmospheric plasma group (466.5 N), the chemical mechanical polishing group (410.8 N), and the control group (382.6 N).</p><p><strong>Conclusion: </strong>It was determined that airborne particle abrasion, hydrogen peroxide etching, and atmospheric plasma treatments significantly increased the crown retention and that all alternative treatments, except for TiO<sub>2</sub> nano coating, worked better than the untreated control.</p>\",\"PeriodicalId\":50292,\"journal\":{\"name\":\"International Journal of Prosthodontics\",\"volume\":\"36 1\",\"pages\":\"49–58\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.6602\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.6602","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Effect of Different Surface Treatments on Retention of Cement-Retained, Implant-Supported Crowns
Purpose: To evaluate the effect of different treatments applied to titanium implant abutment surfaces on the retention of implant-supported cement-retained crowns using resin cement.
Materials and methods: A total of 72 titanium implant abutments were divided into six groups (n = 12 each) based on the selected surface treatments: (1) untreated; (2) airborne particle abrasion; (3) hydrogen peroxide etching; (4) atmospheric plasma; (5) chemical mechanical polishing; and (6) titanium dioxide (TiO2) nano coating. After the surface treatments, scanning electron microscopy analyses and surface roughness measurements of the abutment surfaces were performed. Seventy-two metal copings were fabricated and cemented on the abutments with dual-curing resin cement. After a thermal cycling process, crown retention was measured using a universal testing machine. The experimental results were statistically evaluated with one-way analysis of variance, Tukey honest significant difference, and Tamhane's T2 tests.
Results: The highest surface roughness values were obtained with the airborne-particle abrasion group (1.44 μm), which also resulted in the highest retention values (828.5 N), followed by the hydrogen peroxide-etching group (490.7 N), the atmospheric plasma group (466.5 N), the chemical mechanical polishing group (410.8 N), and the control group (382.6 N).
Conclusion: It was determined that airborne particle abrasion, hydrogen peroxide etching, and atmospheric plasma treatments significantly increased the crown retention and that all alternative treatments, except for TiO2 nano coating, worked better than the untreated control.
期刊介绍:
Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP)
Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.