Wycope视频喉镜、C-MAC视频喉镜与直接喉镜在择期手术患者插管中的效果比较。

Q3 Medicine Acta medica academica Pub Date : 2022-08-01 DOI:10.5644/ama2006-124.378
Jayadi Jayadi, Anna Surgean Veterini, Edward Kusuma, Christrijogo Sumartono Waloejo, Prananda Surya Airlangga, Bambang Pujo Semedi
{"title":"Wycope视频喉镜、C-MAC视频喉镜与直接喉镜在择期手术患者插管中的效果比较。","authors":"Jayadi Jayadi,&nbsp;Anna Surgean Veterini,&nbsp;Edward Kusuma,&nbsp;Christrijogo Sumartono Waloejo,&nbsp;Prananda Surya Airlangga,&nbsp;Bambang Pujo Semedi","doi":"10.5644/ama2006-124.378","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Airway management has undergone a dramatic transformation since the arrival of video laryngoscope (VL). VL has higher intubation success rate on first try and lower complications in comparison to direct laryngoscope (DL). The use of VL is recommended in intubating COVID-19 patients to speed up intubation time and reduce failure rate. A team from Airlangga University developed Wycope Video Laryngoscope (Wycope VL), a VL with Wi-Fi connection to smartphones for an easier VL with low cost. This study aimed to compare the effectiveness of Wycope VL, C-MAC Video Laryngoscope (C-MAC VL), and DL.</p><p><strong>Materials and methods: </strong>This study was an analytic observational study with a cross sectional design, involving 63 patients who were divided into 3 groups based on the type of laryngoscope, namely Wycope VL, C-MAC VL, and DL. Intubation is carried out by 4th year anaesthesiology resident. Research subjects were patients who will undergo elective surgery at Dr. Soetomo General Hospital under general anaesthesia using orotracheal tube. Inclusion age of 19-64 years, PS ASA 1-2, no anatomical abnormalities of the airway, did not have difficult airway, and was willing to participate in the study.</p><p><strong>Results: </strong>All patients were successfully intubated without complications. C-MAC VL (5.33±1.42 seconds) and Wycope VL (5.95±0.74 seconds) was significantly faster in seeing vocal folds and glottis compared to DL (7.14±0.72 seconds) with P=0.000. DL was significantly faster in average time of intubation (15.52±5.90 seconds) compared to C-MAC VL (16.95±1.11 seconds) and Wycope VL (20.29±2.81 seconds) with P=0.000.</p><p><strong>Conclusion: </strong>DL was faster compared to VL in speed of intubation while C-MAC VL and Wycope VL was faster in viewing the vocal folds and glottis compared to DL.</p>","PeriodicalId":38313,"journal":{"name":"Acta medica academica","volume":"51 2","pages":"99-107"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d8/dc/AMA-51-99.PMC9982846.pdf","citationCount":"1","resultStr":"{\"title\":\"Comparison of Effectiveness between Wycope Video Laryngoscope, C-MAC Video Laryngoscope, and Direct Laryngoscope in Intubation of Elective Surgery Patients.\",\"authors\":\"Jayadi Jayadi,&nbsp;Anna Surgean Veterini,&nbsp;Edward Kusuma,&nbsp;Christrijogo Sumartono Waloejo,&nbsp;Prananda Surya Airlangga,&nbsp;Bambang Pujo Semedi\",\"doi\":\"10.5644/ama2006-124.378\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Airway management has undergone a dramatic transformation since the arrival of video laryngoscope (VL). VL has higher intubation success rate on first try and lower complications in comparison to direct laryngoscope (DL). The use of VL is recommended in intubating COVID-19 patients to speed up intubation time and reduce failure rate. A team from Airlangga University developed Wycope Video Laryngoscope (Wycope VL), a VL with Wi-Fi connection to smartphones for an easier VL with low cost. This study aimed to compare the effectiveness of Wycope VL, C-MAC Video Laryngoscope (C-MAC VL), and DL.</p><p><strong>Materials and methods: </strong>This study was an analytic observational study with a cross sectional design, involving 63 patients who were divided into 3 groups based on the type of laryngoscope, namely Wycope VL, C-MAC VL, and DL. Intubation is carried out by 4th year anaesthesiology resident. Research subjects were patients who will undergo elective surgery at Dr. Soetomo General Hospital under general anaesthesia using orotracheal tube. Inclusion age of 19-64 years, PS ASA 1-2, no anatomical abnormalities of the airway, did not have difficult airway, and was willing to participate in the study.</p><p><strong>Results: </strong>All patients were successfully intubated without complications. C-MAC VL (5.33±1.42 seconds) and Wycope VL (5.95±0.74 seconds) was significantly faster in seeing vocal folds and glottis compared to DL (7.14±0.72 seconds) with P=0.000. DL was significantly faster in average time of intubation (15.52±5.90 seconds) compared to C-MAC VL (16.95±1.11 seconds) and Wycope VL (20.29±2.81 seconds) with P=0.000.</p><p><strong>Conclusion: </strong>DL was faster compared to VL in speed of intubation while C-MAC VL and Wycope VL was faster in viewing the vocal folds and glottis compared to DL.</p>\",\"PeriodicalId\":38313,\"journal\":{\"name\":\"Acta medica academica\",\"volume\":\"51 2\",\"pages\":\"99-107\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d8/dc/AMA-51-99.PMC9982846.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta medica academica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5644/ama2006-124.378\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta medica academica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5644/ama2006-124.378","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

摘要

目的:自视频喉镜(VL)问世以来,气道管理发生了巨大的变化。与直接喉镜(DL)相比,VL首次插管成功率高,并发症少。建议在COVID-19患者插管时使用VL,加快插管时间,降低失败率。来自Airlangga大学的一个团队开发了Wycope视频喉镜(Wycope VL),这是一种可以通过Wi-Fi连接智能手机的喉镜,可以更轻松地进行低成本的喉镜检查。本研究旨在比较Wycope VL、C-MAC视频喉镜(C-MAC VL)和DL的有效性。材料与方法:本研究为横断面设计的分析观察性研究,纳入63例患者,根据喉镜类型分为3组,分别为Wycope VL、C-MAC VL和DL。插管由麻醉学住院医师进行。研究对象为将在Dr. Soetomo综合医院接受口气管管全身麻醉的择期手术患者。纳入年龄19-64岁,PS ASA 1-2,气道无解剖异常,无气道困难,自愿参加研究。结果:所有患者插管成功,无并发症。C-MAC VL(5.33±1.42秒)和Wycope VL(5.95±0.74秒)在发现声带和声门方面明显快于DL(7.14±0.72秒),P=0.000。DL平均插管时间(15.52±5.90 s)明显快于C-MAC VL(16.95±1.11 s)和Wycope VL(20.29±2.81 s), P=0.000。结论:DL在插管速度上比VL快,C-MAC VL和Wycope VL在观察声带和声门上比DL快。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Effectiveness between Wycope Video Laryngoscope, C-MAC Video Laryngoscope, and Direct Laryngoscope in Intubation of Elective Surgery Patients.

Objective: Airway management has undergone a dramatic transformation since the arrival of video laryngoscope (VL). VL has higher intubation success rate on first try and lower complications in comparison to direct laryngoscope (DL). The use of VL is recommended in intubating COVID-19 patients to speed up intubation time and reduce failure rate. A team from Airlangga University developed Wycope Video Laryngoscope (Wycope VL), a VL with Wi-Fi connection to smartphones for an easier VL with low cost. This study aimed to compare the effectiveness of Wycope VL, C-MAC Video Laryngoscope (C-MAC VL), and DL.

Materials and methods: This study was an analytic observational study with a cross sectional design, involving 63 patients who were divided into 3 groups based on the type of laryngoscope, namely Wycope VL, C-MAC VL, and DL. Intubation is carried out by 4th year anaesthesiology resident. Research subjects were patients who will undergo elective surgery at Dr. Soetomo General Hospital under general anaesthesia using orotracheal tube. Inclusion age of 19-64 years, PS ASA 1-2, no anatomical abnormalities of the airway, did not have difficult airway, and was willing to participate in the study.

Results: All patients were successfully intubated without complications. C-MAC VL (5.33±1.42 seconds) and Wycope VL (5.95±0.74 seconds) was significantly faster in seeing vocal folds and glottis compared to DL (7.14±0.72 seconds) with P=0.000. DL was significantly faster in average time of intubation (15.52±5.90 seconds) compared to C-MAC VL (16.95±1.11 seconds) and Wycope VL (20.29±2.81 seconds) with P=0.000.

Conclusion: DL was faster compared to VL in speed of intubation while C-MAC VL and Wycope VL was faster in viewing the vocal folds and glottis compared to DL.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta medica academica
Acta medica academica Medicine-Medicine (all)
CiteScore
1.90
自引率
0.00%
发文量
21
审稿时长
15 weeks
期刊最新文献
Inborn Errors of Immunity: New Insights. Resilience in the Face of War: a Collaborative Autoethnography of a Ukrainian Refugee Student's Journey through Europe Striving to Find Oneself. Anatomical Variations of the Vermiform Appendix. Morphometric Analysis of the Greater Palatine Foramina in the Bosnia and Herzegovina Population. HPV-Related Cancers in Bosnia and Herzegovina: A Comprehensive Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1