AR絮凝剂100对燃煤电厂反渗透剩余物的预处理

E. Fosso-Kankeu, L. V. Schalkwyk, F. Waanders, G. Gericke
{"title":"AR絮凝剂100对燃煤电厂反渗透剩余物的预处理","authors":"E. Fosso-Kankeu, L. V. Schalkwyk, F. Waanders, G. Gericke","doi":"10.17758/eares4.eap1118241","DOIUrl":null,"url":null,"abstract":"The water purification process at Eskom includes a reverse osmosis (RO) treatment plant. There are several limitations to this process depending on the water characteristics. The most common problems limiting the success of water purification include scaling, biological fouling and corrosion. This study is mainly focused on reducing scale forming agents in the RO system. Scaling is the precipitation of calcium and magnesium salts onto the equipment, primarily the RO membrane. These salts start to precipitate once the salt concentration in the water is higher than the allowable solubility constant. These salts can be removed from the water by a process called coagulation-flocculation. The success of such process is partly dependent on the type of flocculant and the dosage used. In this study the performances of one coagulant namely Rheofloc 5023 in combination with three flocculants including Rheofloc 5414, Genesys genefloc and AR floc 100 were tested at various dosages for the reduction of conductivity assimilated with ions in the RO retentate from coal power plant was investigated at 40 and 60C. The AR floc 100 was determined to be the optimum flocculant required for the RO reject treatment. The optimum flocculant dosage resulted in 1 ppm along with a Rheofloc 5023 coagulant dosage of 0.7 ppm. Keywords—AR floc 100, RO retentate, flocculation, conductivity.","PeriodicalId":8495,"journal":{"name":"ASETH-18,ACABES-18 & EBHSSS-18 Nov. 19-20 2018 Cape Town (South Africa)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pretreatment of Coal Power Plant RO Retentate using AR floc 100\",\"authors\":\"E. Fosso-Kankeu, L. V. Schalkwyk, F. Waanders, G. Gericke\",\"doi\":\"10.17758/eares4.eap1118241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The water purification process at Eskom includes a reverse osmosis (RO) treatment plant. There are several limitations to this process depending on the water characteristics. The most common problems limiting the success of water purification include scaling, biological fouling and corrosion. This study is mainly focused on reducing scale forming agents in the RO system. Scaling is the precipitation of calcium and magnesium salts onto the equipment, primarily the RO membrane. These salts start to precipitate once the salt concentration in the water is higher than the allowable solubility constant. These salts can be removed from the water by a process called coagulation-flocculation. The success of such process is partly dependent on the type of flocculant and the dosage used. In this study the performances of one coagulant namely Rheofloc 5023 in combination with three flocculants including Rheofloc 5414, Genesys genefloc and AR floc 100 were tested at various dosages for the reduction of conductivity assimilated with ions in the RO retentate from coal power plant was investigated at 40 and 60C. The AR floc 100 was determined to be the optimum flocculant required for the RO reject treatment. The optimum flocculant dosage resulted in 1 ppm along with a Rheofloc 5023 coagulant dosage of 0.7 ppm. Keywords—AR floc 100, RO retentate, flocculation, conductivity.\",\"PeriodicalId\":8495,\"journal\":{\"name\":\"ASETH-18,ACABES-18 & EBHSSS-18 Nov. 19-20 2018 Cape Town (South Africa)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ASETH-18,ACABES-18 & EBHSSS-18 Nov. 19-20 2018 Cape Town (South Africa)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17758/eares4.eap1118241\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASETH-18,ACABES-18 & EBHSSS-18 Nov. 19-20 2018 Cape Town (South Africa)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17758/eares4.eap1118241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Eskom的水净化过程包括一个反渗透(RO)处理厂。根据水的特性,这个过程有几个限制。限制水净化成功的最常见问题包括结垢、生物污染和腐蚀。本研究主要针对反渗透系统中的降垢剂进行研究。结垢是钙和镁盐在设备上的沉淀,主要是反渗透膜。一旦水中的盐浓度高于允许的溶解度常数,这些盐就开始沉淀。这些盐可以通过一种叫做混凝-絮凝的方法从水中去除。该工艺的成功与否部分取决于絮凝剂的种类和用量。在本研究中,研究了一种混凝剂(Rheofloc 5023)与三种絮凝剂(Rheofloc 5414、Genesys genefloc和AR絮凝剂100)在不同剂量下的性能,以降低40℃和60℃下燃煤电厂RO保留液中离子吸收的电导率。确定了AR絮凝剂100为反渗透废水处理所需的最佳絮凝剂。最佳絮凝剂投加量为1ppm, Rheofloc 5023投加量为0.7 ppm。关键词:ar絮凝剂100;反渗透;絮凝;
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Pretreatment of Coal Power Plant RO Retentate using AR floc 100
The water purification process at Eskom includes a reverse osmosis (RO) treatment plant. There are several limitations to this process depending on the water characteristics. The most common problems limiting the success of water purification include scaling, biological fouling and corrosion. This study is mainly focused on reducing scale forming agents in the RO system. Scaling is the precipitation of calcium and magnesium salts onto the equipment, primarily the RO membrane. These salts start to precipitate once the salt concentration in the water is higher than the allowable solubility constant. These salts can be removed from the water by a process called coagulation-flocculation. The success of such process is partly dependent on the type of flocculant and the dosage used. In this study the performances of one coagulant namely Rheofloc 5023 in combination with three flocculants including Rheofloc 5414, Genesys genefloc and AR floc 100 were tested at various dosages for the reduction of conductivity assimilated with ions in the RO retentate from coal power plant was investigated at 40 and 60C. The AR floc 100 was determined to be the optimum flocculant required for the RO reject treatment. The optimum flocculant dosage resulted in 1 ppm along with a Rheofloc 5023 coagulant dosage of 0.7 ppm. Keywords—AR floc 100, RO retentate, flocculation, conductivity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical case of peripheral facial palsy as first and single COVID-19 symptom in an immunized patient Level of compliance of patients with alcohol dependence at the stages of active treatment of alcohol misuse The influence of the sleep disturbances on the quality of patients` life with anxiety-depressive disorders of neurotic and organic genesis Characteristics of cognitive impairment in multiple sclerosis patients depending on different risk factors Constitutional psychic human qualities influence on the emotional and psychic state at the patients with neurological spine disorders
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1