一种基于分子印迹聚合物(MIP)的新型维生素D3检测伏安传感器

S. Kia
{"title":"一种基于分子印迹聚合物(MIP)的新型维生素D3检测伏安传感器","authors":"S. Kia","doi":"10.1109/BIA48344.2019.8967459","DOIUrl":null,"url":null,"abstract":"an extremely sensitive electrochemical sensor for vitamin D3 is fabricated based on hybrid imprinted polymer. A vitamin D3 absorptive molecularly imprinted polymer (MIP) are synthesized in the present of multi-walled carbon nanotubes (MWCNTs), and then mixed with graphite powder and n-eicosane as a binder for construction of carbon paste electrodes (CPEs). Electro oxidation of vitamin D3 is considered with this modified electrode. Several aspects of modified electrode construction was considered and improved. This linearity range of sensor was 5 × 10−8–7 × 10−6 M and lower detection limit was 3 × 10−8 M. The presented sensor was efficient for vitamin D3 quantification in real samples.","PeriodicalId":6688,"journal":{"name":"2019 International Conference on Biomedical Innovations and Applications (BIA)","volume":"4 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A new Voltametric sensor, based on molecularly imprinted polymer (MIP) for vitamin D3 Detection\",\"authors\":\"S. Kia\",\"doi\":\"10.1109/BIA48344.2019.8967459\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"an extremely sensitive electrochemical sensor for vitamin D3 is fabricated based on hybrid imprinted polymer. A vitamin D3 absorptive molecularly imprinted polymer (MIP) are synthesized in the present of multi-walled carbon nanotubes (MWCNTs), and then mixed with graphite powder and n-eicosane as a binder for construction of carbon paste electrodes (CPEs). Electro oxidation of vitamin D3 is considered with this modified electrode. Several aspects of modified electrode construction was considered and improved. This linearity range of sensor was 5 × 10−8–7 × 10−6 M and lower detection limit was 3 × 10−8 M. The presented sensor was efficient for vitamin D3 quantification in real samples.\",\"PeriodicalId\":6688,\"journal\":{\"name\":\"2019 International Conference on Biomedical Innovations and Applications (BIA)\",\"volume\":\"4 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Biomedical Innovations and Applications (BIA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIA48344.2019.8967459\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Biomedical Innovations and Applications (BIA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIA48344.2019.8967459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

基于杂化印迹聚合物制备了一种极灵敏的维生素D3电化学传感器。在多壁碳纳米管(MWCNTs)的存在下合成了维生素D3吸收性分子印迹聚合物(MIP),并与石墨粉和正二十烷作为粘合剂混合,用于构建碳糊电极(cpe)。用这种修饰电极考虑了维生素D3的电氧化。对改进电极结构的几个方面进行了考虑和改进。该传感器的线性范围为5 × 10−8 ~ 7 × 10−6 M,下检出限为3 × 10−8 M,可用于实际样品中维生素D3的定量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A new Voltametric sensor, based on molecularly imprinted polymer (MIP) for vitamin D3 Detection
an extremely sensitive electrochemical sensor for vitamin D3 is fabricated based on hybrid imprinted polymer. A vitamin D3 absorptive molecularly imprinted polymer (MIP) are synthesized in the present of multi-walled carbon nanotubes (MWCNTs), and then mixed with graphite powder and n-eicosane as a binder for construction of carbon paste electrodes (CPEs). Electro oxidation of vitamin D3 is considered with this modified electrode. Several aspects of modified electrode construction was considered and improved. This linearity range of sensor was 5 × 10−8–7 × 10−6 M and lower detection limit was 3 × 10−8 M. The presented sensor was efficient for vitamin D3 quantification in real samples.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
CLAS: A Database for Cognitive Load, Affect and Stress Recognition Fucntional Modification of Upper Limb Prosthesis for Below Elbow Congential Deficiencies Application of Smart Contracts based on Ethereum Blockchain for the Purpose of Insurance Services Coping with missing data in an unobtrusive monitoring system for office workers An Approach to Improve Reliability of Vital Signs Monitoring
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1