Wesam A. Mokhtar, N. Kamal, L. Sherief, Sherief Z. Kamel
{"title":"机械通气新生儿的死亡风险:发展中国家的经验","authors":"Wesam A. Mokhtar, N. Kamal, L. Sherief, Sherief Z. Kamel","doi":"10.22038/IJN.2021.33734.1488","DOIUrl":null,"url":null,"abstract":"Background & Objectives:Despite the great improvement in the outcome of sick neonates after the effective widespread introduction of mechanical ventilation in neonatal intensive care units, a significant proportion of high fatality is still detected among them. This study was conducted to identify the complications, outcome, and causes of death among a sample of critically ill Egyptian neonates mechanically ventilated using pressure-control-mode.Patients & Methods:Two-hundred-forty patients fulfilling the study inclusion criteria were prospectively enrolled in the current study. Those with multiple congenital malformations or post-surgical cases were excluded from the study. Data regarding history taking, clinical examination, indication for mechanical ventilation, complications related to mechanical ventilation and outcome were collected, recorded and analyzed. Results: The incidence of complications related to mechanical ventilation was 104 (43.3%) with reported increase in the incidence of VAP (20%). Also, the incidence of complications related to disease pattern was 136 (56.7%) with reported increase in the incidence of sepsis & septic shock (22.5%). It has been observed that 124 (51.7%) of the studied neonates had favorable outcome, however, the remaining 116 (48.3%) unfortunately expired with significant increase in the incidence of VAP among the expired group (P=0.013). Smaller gestational age and lower birth weight were the most significant risk factors. Conclusions:In Egypt; as an example of developing countries; mortality among critically ill mechanically ventilated pressure-control-mode neonates is significantly high approaching 48.3% with VAP being the most common cause of death.","PeriodicalId":14584,"journal":{"name":"Iranian Journal of Neonatology IJN","volume":"39 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Mortality Risk in Mechanically Ventilated Neonates: A Developing Country Experience\",\"authors\":\"Wesam A. Mokhtar, N. Kamal, L. Sherief, Sherief Z. Kamel\",\"doi\":\"10.22038/IJN.2021.33734.1488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background & Objectives:Despite the great improvement in the outcome of sick neonates after the effective widespread introduction of mechanical ventilation in neonatal intensive care units, a significant proportion of high fatality is still detected among them. This study was conducted to identify the complications, outcome, and causes of death among a sample of critically ill Egyptian neonates mechanically ventilated using pressure-control-mode.Patients & Methods:Two-hundred-forty patients fulfilling the study inclusion criteria were prospectively enrolled in the current study. Those with multiple congenital malformations or post-surgical cases were excluded from the study. Data regarding history taking, clinical examination, indication for mechanical ventilation, complications related to mechanical ventilation and outcome were collected, recorded and analyzed. Results: The incidence of complications related to mechanical ventilation was 104 (43.3%) with reported increase in the incidence of VAP (20%). Also, the incidence of complications related to disease pattern was 136 (56.7%) with reported increase in the incidence of sepsis & septic shock (22.5%). It has been observed that 124 (51.7%) of the studied neonates had favorable outcome, however, the remaining 116 (48.3%) unfortunately expired with significant increase in the incidence of VAP among the expired group (P=0.013). Smaller gestational age and lower birth weight were the most significant risk factors. Conclusions:In Egypt; as an example of developing countries; mortality among critically ill mechanically ventilated pressure-control-mode neonates is significantly high approaching 48.3% with VAP being the most common cause of death.\",\"PeriodicalId\":14584,\"journal\":{\"name\":\"Iranian Journal of Neonatology IJN\",\"volume\":\"39 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Neonatology IJN\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22038/IJN.2021.33734.1488\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Neonatology IJN","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJN.2021.33734.1488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Mortality Risk in Mechanically Ventilated Neonates: A Developing Country Experience
Background & Objectives:Despite the great improvement in the outcome of sick neonates after the effective widespread introduction of mechanical ventilation in neonatal intensive care units, a significant proportion of high fatality is still detected among them. This study was conducted to identify the complications, outcome, and causes of death among a sample of critically ill Egyptian neonates mechanically ventilated using pressure-control-mode.Patients & Methods:Two-hundred-forty patients fulfilling the study inclusion criteria were prospectively enrolled in the current study. Those with multiple congenital malformations or post-surgical cases were excluded from the study. Data regarding history taking, clinical examination, indication for mechanical ventilation, complications related to mechanical ventilation and outcome were collected, recorded and analyzed. Results: The incidence of complications related to mechanical ventilation was 104 (43.3%) with reported increase in the incidence of VAP (20%). Also, the incidence of complications related to disease pattern was 136 (56.7%) with reported increase in the incidence of sepsis & septic shock (22.5%). It has been observed that 124 (51.7%) of the studied neonates had favorable outcome, however, the remaining 116 (48.3%) unfortunately expired with significant increase in the incidence of VAP among the expired group (P=0.013). Smaller gestational age and lower birth weight were the most significant risk factors. Conclusions:In Egypt; as an example of developing countries; mortality among critically ill mechanically ventilated pressure-control-mode neonates is significantly high approaching 48.3% with VAP being the most common cause of death.