{"title":"游隼系统输注导管用于高血压神经溶解性肾去神经:其安全性和有效性综述。","authors":"Adam Janas, Wojciech Wojakowski","doi":"10.1080/17434440.2023.2183838","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Resistant hypertension (HTN), despite the tremendous advances in pharmacotherapy, is a major global problem. Transcatheter renal denervation (RDN) could be a pertinent strategy for resistant HTN and patients with poor pharmacotherapy adherence. Nonetheless, the adoption of energy-based RDN in clinical practice is slow and alternative approaches are needed.</p><p><strong>Areas covered: </strong>The review focuses on the assessment of the Peregrine System Infusion Catheters. The system is designed for chemically mediated transcatheter RDN by the infusion publications on the Peregrine system. The theoretical assumptions for chemically mediated RDN, design of the system, data from preclinical and clinical studies, and further perspectives are discussed.</p><p><strong>Expert opinion: </strong>Peregrine System Infusion Catheters are the only catheter on the market designed for chemically mediated RDN by the infusion of the neurolytic agent. Chemical neurolysis more efficiently destroys nerves around the renal artery in comparison to energy-based catheters, due to deeper tissue penetration and circumferential distribution resulting in a wider range of effective nerve injury. Chemically mediated RDN by the infusion of the neurolytic agent (alcohol) has an excellent safety profile as confirmed in initial clinical trials which also suggested high efficacy. Currently, there is an ongoing phase III sham-control study. Other possible applications of this technology include clinical settings like heart failure or atrial fibrillation.</p>","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":"20 3","pages":"179-186"},"PeriodicalIF":2.9000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Peregrine system infusion catheter for neurolytic renal denervation in hypertension: an overview of its safety and efficacy.\",\"authors\":\"Adam Janas, Wojciech Wojakowski\",\"doi\":\"10.1080/17434440.2023.2183838\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Resistant hypertension (HTN), despite the tremendous advances in pharmacotherapy, is a major global problem. Transcatheter renal denervation (RDN) could be a pertinent strategy for resistant HTN and patients with poor pharmacotherapy adherence. Nonetheless, the adoption of energy-based RDN in clinical practice is slow and alternative approaches are needed.</p><p><strong>Areas covered: </strong>The review focuses on the assessment of the Peregrine System Infusion Catheters. The system is designed for chemically mediated transcatheter RDN by the infusion publications on the Peregrine system. The theoretical assumptions for chemically mediated RDN, design of the system, data from preclinical and clinical studies, and further perspectives are discussed.</p><p><strong>Expert opinion: </strong>Peregrine System Infusion Catheters are the only catheter on the market designed for chemically mediated RDN by the infusion of the neurolytic agent. Chemical neurolysis more efficiently destroys nerves around the renal artery in comparison to energy-based catheters, due to deeper tissue penetration and circumferential distribution resulting in a wider range of effective nerve injury. Chemically mediated RDN by the infusion of the neurolytic agent (alcohol) has an excellent safety profile as confirmed in initial clinical trials which also suggested high efficacy. Currently, there is an ongoing phase III sham-control study. Other possible applications of this technology include clinical settings like heart failure or atrial fibrillation.</p>\",\"PeriodicalId\":12330,\"journal\":{\"name\":\"Expert Review of Medical Devices\",\"volume\":\"20 3\",\"pages\":\"179-186\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert Review of Medical Devices\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2023.2183838\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Medical Devices","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2183838","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Peregrine system infusion catheter for neurolytic renal denervation in hypertension: an overview of its safety and efficacy.
Introduction: Resistant hypertension (HTN), despite the tremendous advances in pharmacotherapy, is a major global problem. Transcatheter renal denervation (RDN) could be a pertinent strategy for resistant HTN and patients with poor pharmacotherapy adherence. Nonetheless, the adoption of energy-based RDN in clinical practice is slow and alternative approaches are needed.
Areas covered: The review focuses on the assessment of the Peregrine System Infusion Catheters. The system is designed for chemically mediated transcatheter RDN by the infusion publications on the Peregrine system. The theoretical assumptions for chemically mediated RDN, design of the system, data from preclinical and clinical studies, and further perspectives are discussed.
Expert opinion: Peregrine System Infusion Catheters are the only catheter on the market designed for chemically mediated RDN by the infusion of the neurolytic agent. Chemical neurolysis more efficiently destroys nerves around the renal artery in comparison to energy-based catheters, due to deeper tissue penetration and circumferential distribution resulting in a wider range of effective nerve injury. Chemically mediated RDN by the infusion of the neurolytic agent (alcohol) has an excellent safety profile as confirmed in initial clinical trials which also suggested high efficacy. Currently, there is an ongoing phase III sham-control study. Other possible applications of this technology include clinical settings like heart failure or atrial fibrillation.
期刊介绍:
The journal serves the device research community by providing a comprehensive body of high-quality information from leading experts, all subject to rigorous peer review. The Expert Review format is specially structured to optimize the value of the information to reader. Comprehensive coverage by each author in a key area of research or clinical practice is augmented by the following sections:
Expert commentary - a personal view on the most effective or promising strategies
Five-year view - a clear perspective of future prospects within a realistic timescale
Key issues - an executive summary cutting to the author''s most critical points
In addition to the Review program, each issue also features Medical Device Profiles - objective assessments of specific devices in development or clinical use to help inform clinical practice. There are also Perspectives - overviews highlighting areas of current debate and controversy, together with reports from the conference scene and invited Editorials.