大规模风能与太阳能并网对孤岛电力系统运行备用需求的影响

M.H.T.T. Thilekha, K. Siriwardana, N. Siebel, D.A.D. Waslathanthri, N. Lidula, T. Siyambalapitiya, A. Wickramasinghe
{"title":"大规模风能与太阳能并网对孤岛电力系统运行备用需求的影响","authors":"M.H.T.T. Thilekha, K. Siriwardana, N. Siebel, D.A.D. Waslathanthri, N. Lidula, T. Siyambalapitiya, A. Wickramasinghe","doi":"10.1109/MERCON.2018.8421919","DOIUrl":null,"url":null,"abstract":"Many nations have shown their support to a battle against environmental pollution by integrating large scale solar and wind energy resources, to their respective grids. Although these commendable efforts have paved the way for a greener future, it has to be noted that non-conventional renewable energy (NCRE) possess their own inherent drawbacks. Their availability is highly dependent on the prevalent weather conditions, which means that they are subjected to uncontrollable variability. With the rise of intermittent renewable resources, it is important to have appropriate amounts of operating reserves to provide back-up to the system. This will ensure that the system will be stable under variable power conditions and thus, improve the reliability of the system. This paper is focused in quantifying additional operating reserves requirements to stabilize the system under intermittent conditions with the large penetration of renewables into an islanded power system. It assesses the spinning reserve requirement during the high wind and low wind seasons.","PeriodicalId":6603,"journal":{"name":"2018 Moratuwa Engineering Research Conference (MERCon)","volume":"26 7","pages":"589-594"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Impact of Large-Scale Wind and Solar Power Integration on Operating Reserve Requirements of an Islanded Power System\",\"authors\":\"M.H.T.T. Thilekha, K. Siriwardana, N. Siebel, D.A.D. Waslathanthri, N. Lidula, T. Siyambalapitiya, A. Wickramasinghe\",\"doi\":\"10.1109/MERCON.2018.8421919\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many nations have shown their support to a battle against environmental pollution by integrating large scale solar and wind energy resources, to their respective grids. Although these commendable efforts have paved the way for a greener future, it has to be noted that non-conventional renewable energy (NCRE) possess their own inherent drawbacks. Their availability is highly dependent on the prevalent weather conditions, which means that they are subjected to uncontrollable variability. With the rise of intermittent renewable resources, it is important to have appropriate amounts of operating reserves to provide back-up to the system. This will ensure that the system will be stable under variable power conditions and thus, improve the reliability of the system. This paper is focused in quantifying additional operating reserves requirements to stabilize the system under intermittent conditions with the large penetration of renewables into an islanded power system. It assesses the spinning reserve requirement during the high wind and low wind seasons.\",\"PeriodicalId\":6603,\"journal\":{\"name\":\"2018 Moratuwa Engineering Research Conference (MERCon)\",\"volume\":\"26 7\",\"pages\":\"589-594\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Moratuwa Engineering Research Conference (MERCon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MERCON.2018.8421919\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Moratuwa Engineering Research Conference (MERCon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MERCON.2018.8421919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

许多国家通过将大规模的太阳能和风能资源整合到各自的电网中来支持对抗环境污染的斗争。尽管这些值得称赞的努力为更绿色的未来铺平了道路,但必须指出的是,非常规可再生能源(NCRE)有其固有的缺点。它们的可用性高度依赖于普遍的天气条件,这意味着它们受到无法控制的变化的影响。随着间歇性可再生能源的兴起,有适当数量的运行储备为系统提供备份是很重要的。这将确保系统在变功率条件下保持稳定,从而提高系统的可靠性。本文的重点是量化可再生能源大量渗透到孤岛电力系统的间歇性条件下稳定系统的额外运行储备需求。评估了高风季和低风季的旋转备用需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of Large-Scale Wind and Solar Power Integration on Operating Reserve Requirements of an Islanded Power System
Many nations have shown their support to a battle against environmental pollution by integrating large scale solar and wind energy resources, to their respective grids. Although these commendable efforts have paved the way for a greener future, it has to be noted that non-conventional renewable energy (NCRE) possess their own inherent drawbacks. Their availability is highly dependent on the prevalent weather conditions, which means that they are subjected to uncontrollable variability. With the rise of intermittent renewable resources, it is important to have appropriate amounts of operating reserves to provide back-up to the system. This will ensure that the system will be stable under variable power conditions and thus, improve the reliability of the system. This paper is focused in quantifying additional operating reserves requirements to stabilize the system under intermittent conditions with the large penetration of renewables into an islanded power system. It assesses the spinning reserve requirement during the high wind and low wind seasons.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fired-Siltstone Based Geopolymers for CO2 Sequestration Wells : A Study on the Effect of Curing Temperature Design and Development of a Smart Wheelchair with Multiple Control Interfaces Modelling Transfer Function of Power Transformers Using Sweep Frequency Response Analysis 3D Full-Field Deformation Measuring Technique with Optics-Based Measurements Optimization of Thermal Comfort in Sri Lankan Residential Buildings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1