{"title":"含油废水的超滤净化","authors":"K. Karakulski ,&nbsp;A. Kozlowski ,&nbsp;A.W. Morawski","doi":"10.1016/0956-9618(95)00123-9","DOIUrl":null,"url":null,"abstract":"<div><p>Investigations have been carried out for purification of oily wastewater by a combination of ultrafiltration/reverse osmosis processes. A tubular ultrafiltration system using cellulosic and non-cellulosic membranes was tested with typical oily wastewater collected from harbour and simulated emulsion without any pretreatment. Both membrane types produced a permeate with an oil content generally less than 10 mg/dm<sup>3</sup>. Rejection of chemical oxygen demand (COD) is 80% for ultrafiltration treatment. The permeate is generally of acceptable quality for direct sewer discharge. For further treatment of UF permeate, reverse osmosis was applied with tubular B1 PCI modules using cellulose acetate membranes. The rejection of COD after ultrafiltration/reverse osmosis treatment increased up to 98.5% and total dissolved solids (TDS) to 95.7%. Reverse osmosis treatment will permit reuse of the treated water as process water.</p></div>","PeriodicalId":101160,"journal":{"name":"Separations Technology","volume":"5 4","pages":"Pages 197-205"},"PeriodicalIF":0.0000,"publicationDate":"1995-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0956-9618(95)00123-9","citationCount":"61","resultStr":"{\"title\":\"Purification of oily wastewater by ultrafiltration\",\"authors\":\"K. Karakulski ,&nbsp;A. Kozlowski ,&nbsp;A.W. Morawski\",\"doi\":\"10.1016/0956-9618(95)00123-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Investigations have been carried out for purification of oily wastewater by a combination of ultrafiltration/reverse osmosis processes. A tubular ultrafiltration system using cellulosic and non-cellulosic membranes was tested with typical oily wastewater collected from harbour and simulated emulsion without any pretreatment. Both membrane types produced a permeate with an oil content generally less than 10 mg/dm<sup>3</sup>. Rejection of chemical oxygen demand (COD) is 80% for ultrafiltration treatment. The permeate is generally of acceptable quality for direct sewer discharge. For further treatment of UF permeate, reverse osmosis was applied with tubular B1 PCI modules using cellulose acetate membranes. The rejection of COD after ultrafiltration/reverse osmosis treatment increased up to 98.5% and total dissolved solids (TDS) to 95.7%. Reverse osmosis treatment will permit reuse of the treated water as process water.</p></div>\",\"PeriodicalId\":101160,\"journal\":{\"name\":\"Separations Technology\",\"volume\":\"5 4\",\"pages\":\"Pages 197-205\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0956-9618(95)00123-9\",\"citationCount\":\"61\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Separations Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0956961895001239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Separations Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0956961895001239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 61

摘要

对超滤/反渗透联合处理含油废水进行了研究。以典型港口含油废水和模拟乳化液为原料,对纤维素膜和非纤维素膜管式超滤系统进行了试验研究。两种膜类型产生的渗透液含油量通常小于10 mg/dm3。超滤处理的化学需氧量(COD)去除率达80%。渗液的质量一般可接受,可直接由下水道排放。为了进一步处理超滤渗透,采用醋酸纤维素膜的管状B1 PCI模块进行反渗透。超滤/反渗透处理后的COD去除率可达98.5%,总溶解固溶体(TDS)去除率可达95.7%。反渗透处理将允许处理后的水作为工艺用水重复使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Purification of oily wastewater by ultrafiltration

Investigations have been carried out for purification of oily wastewater by a combination of ultrafiltration/reverse osmosis processes. A tubular ultrafiltration system using cellulosic and non-cellulosic membranes was tested with typical oily wastewater collected from harbour and simulated emulsion without any pretreatment. Both membrane types produced a permeate with an oil content generally less than 10 mg/dm3. Rejection of chemical oxygen demand (COD) is 80% for ultrafiltration treatment. The permeate is generally of acceptable quality for direct sewer discharge. For further treatment of UF permeate, reverse osmosis was applied with tubular B1 PCI modules using cellulose acetate membranes. The rejection of COD after ultrafiltration/reverse osmosis treatment increased up to 98.5% and total dissolved solids (TDS) to 95.7%. Reverse osmosis treatment will permit reuse of the treated water as process water.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Membrane Pervaporation Affinity Chromatography Monoclonal Antibodies Publisher's note Volume contents
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1