四通道脑电图分析支持早期阿尔茨海默病的检测。

IF 6.6 2区 计算机科学 Q1 COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE International Journal of Neural Systems Pub Date : 2023-04-01 DOI:10.1142/S0129065723500211
Eduardo Perez-Valero, Christian Morillas, Miguel A Lopez-Gordo, Jesus Minguillon
{"title":"四通道脑电图分析支持早期阿尔茨海默病的检测。","authors":"Eduardo Perez-Valero,&nbsp;Christian Morillas,&nbsp;Miguel A Lopez-Gordo,&nbsp;Jesus Minguillon","doi":"10.1142/S0129065723500211","DOIUrl":null,"url":null,"abstract":"<p><p>Alzheimer's disease (AD) is the most prevalent form of dementia. Although there is no current cure, medical treatment can help to control its progression. Hence, early-stage diagnosis is crucial to maximize the living standards of the patients. Biochemical markers and medical imaging in combination with neuropsychological tests represent the most extended diagnosis procedure. However, these techniques require specialized personnel and long processing time. Furthermore, the access to some of these techniques is often limited in crowded healthcare systems and rural areas. In this context, electroencephalography (EEG), a non-invasive technique to obtain endogenous brain information, has been proposed for the diagnosis of early-stage AD. Despite the valuable information provided by clinical EEG and high density montages, these approaches are impractical in conditions such as those described above. Consequently, in this study, we evaluated the feasibly of using a reduced EEG montage with only four channels to detect early-stage AD. For this purpose, we involved eight clinically diagnosed AD patients and eight healthy controls. The results we obtained reveal similar accuracies ([Formula: see text]-value[Formula: see text]0.66) for the reduced montage (0.86) and a 16-channel montage (0.87). This suggests that a four-channel wearable EEG system could be an effective tool for supporting early-stage AD detection.</p>","PeriodicalId":50305,"journal":{"name":"International Journal of Neural Systems","volume":null,"pages":null},"PeriodicalIF":6.6000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Supporting the Detection of Early Alzheimer's Disease with a Four-Channel EEG Analysis.\",\"authors\":\"Eduardo Perez-Valero,&nbsp;Christian Morillas,&nbsp;Miguel A Lopez-Gordo,&nbsp;Jesus Minguillon\",\"doi\":\"10.1142/S0129065723500211\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Alzheimer's disease (AD) is the most prevalent form of dementia. Although there is no current cure, medical treatment can help to control its progression. Hence, early-stage diagnosis is crucial to maximize the living standards of the patients. Biochemical markers and medical imaging in combination with neuropsychological tests represent the most extended diagnosis procedure. However, these techniques require specialized personnel and long processing time. Furthermore, the access to some of these techniques is often limited in crowded healthcare systems and rural areas. In this context, electroencephalography (EEG), a non-invasive technique to obtain endogenous brain information, has been proposed for the diagnosis of early-stage AD. Despite the valuable information provided by clinical EEG and high density montages, these approaches are impractical in conditions such as those described above. Consequently, in this study, we evaluated the feasibly of using a reduced EEG montage with only four channels to detect early-stage AD. For this purpose, we involved eight clinically diagnosed AD patients and eight healthy controls. The results we obtained reveal similar accuracies ([Formula: see text]-value[Formula: see text]0.66) for the reduced montage (0.86) and a 16-channel montage (0.87). This suggests that a four-channel wearable EEG system could be an effective tool for supporting early-stage AD detection.</p>\",\"PeriodicalId\":50305,\"journal\":{\"name\":\"International Journal of Neural Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":6.6000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Neural Systems\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://doi.org/10.1142/S0129065723500211\",\"RegionNum\":2,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Neural Systems","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1142/S0129065723500211","RegionNum":2,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE","Score":null,"Total":0}
引用次数: 0

摘要

阿尔茨海默病(AD)是最常见的痴呆症。虽然目前还没有治愈方法,但药物治疗可以帮助控制病情的发展。因此,早期诊断对于最大限度地提高患者的生活水平至关重要。生化标记和医学影像结合神经心理测试代表了最广泛的诊断程序。然而,这些技术需要专门的人员和较长的处理时间。此外,在拥挤的卫生保健系统和农村地区,获得其中一些技术的机会往往有限。在此背景下,脑电图(EEG)作为一种获取内源性大脑信息的非侵入性技术,已被提出用于早期AD的诊断。尽管临床脑电图和高密度蒙太奇提供了有价值的信息,但这些方法在上述情况下是不切实际的。因此,在本研究中,我们评估了使用只有四个通道的简化脑电图蒙太奇来检测早期AD的可行性。为此,我们纳入了8名临床诊断为AD的患者和8名健康对照。我们获得的结果显示,减少蒙太奇(0.86)和16通道蒙太奇(0.87)的精确度相似([公式:见文本]-值[公式:见文本]0.66)。这表明四通道可穿戴脑电图系统可能是支持早期AD检测的有效工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Supporting the Detection of Early Alzheimer's Disease with a Four-Channel EEG Analysis.

Alzheimer's disease (AD) is the most prevalent form of dementia. Although there is no current cure, medical treatment can help to control its progression. Hence, early-stage diagnosis is crucial to maximize the living standards of the patients. Biochemical markers and medical imaging in combination with neuropsychological tests represent the most extended diagnosis procedure. However, these techniques require specialized personnel and long processing time. Furthermore, the access to some of these techniques is often limited in crowded healthcare systems and rural areas. In this context, electroencephalography (EEG), a non-invasive technique to obtain endogenous brain information, has been proposed for the diagnosis of early-stage AD. Despite the valuable information provided by clinical EEG and high density montages, these approaches are impractical in conditions such as those described above. Consequently, in this study, we evaluated the feasibly of using a reduced EEG montage with only four channels to detect early-stage AD. For this purpose, we involved eight clinically diagnosed AD patients and eight healthy controls. The results we obtained reveal similar accuracies ([Formula: see text]-value[Formula: see text]0.66) for the reduced montage (0.86) and a 16-channel montage (0.87). This suggests that a four-channel wearable EEG system could be an effective tool for supporting early-stage AD detection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Neural Systems
International Journal of Neural Systems 工程技术-计算机:人工智能
CiteScore
11.30
自引率
28.80%
发文量
116
审稿时长
24 months
期刊介绍: The International Journal of Neural Systems is a monthly, rigorously peer-reviewed transdisciplinary journal focusing on information processing in both natural and artificial neural systems. Special interests include machine learning, computational neuroscience and neurology. The journal prioritizes innovative, high-impact articles spanning multiple fields, including neurosciences and computer science and engineering. It adopts an open-minded approach to this multidisciplinary field, serving as a platform for novel ideas and enhanced understanding of collective and cooperative phenomena in computationally capable systems.
期刊最新文献
Wavelet Transform, Reconstructed Phase Space, and Deep Learning Neural Networks for EEG-based Schizophrenia Detection Unsupervised EEG-Based Seizure Anomaly Detection with Denoising Diffusion Probabilistic Models Incremental Confidence Sampling with Optimal Transport for Domain Adaptation A model with dopamine depletion in basal ganglia and cerebellum predicts changes in thalamocortical beta oscillations Epileptic Seizure Prediction Using Spatiotemporal Feature Fusion on EEG
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1