三维打印引导主动脉弓三支重建中的瓣膜/分枝TEVAR疗效分析。

IF 1.7 2区 医学 Q3 PERIPHERAL VASCULAR DISEASE Journal of Endovascular Therapy Pub Date : 2024-12-01 Epub Date: 2023-03-21 DOI:10.1177/15266028231161244
Dong-Sheng Fu, Yi Jin, Zi-He Zhao, Chao Wang, Ying-Huan Shi, Ming-Jie Zhou, Jing-Xiong Zhao, Chen Liu, Tong Qiao, Chang-Jian Liu, Xiao-Qiang Li, Wen-Dong Li, Zhao Liu
{"title":"三维打印引导主动脉弓三支重建中的瓣膜/分枝TEVAR疗效分析。","authors":"Dong-Sheng Fu, Yi Jin, Zi-He Zhao, Chao Wang, Ying-Huan Shi, Ming-Jie Zhou, Jing-Xiong Zhao, Chen Liu, Tong Qiao, Chang-Jian Liu, Xiao-Qiang Li, Wen-Dong Li, Zhao Liu","doi":"10.1177/15266028231161244","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To summarize experience with and the efficacy of fenestrated/branched thoracic endovascular repair (F/B-TEVAR) using physician-modified stent-grafts (PMSGs) under 3D printing guidance in triple aortic arch branch reconstruction.</p><p><strong>Materials and methods: </strong>From February 2018 to April 2022, 14 cases of aortic arch aneurysms and 30 cases of aortic arch dissection (22 acute aortic arch dissection and 8 long-term aortic arch dissection)were treated by F/B-TEVAR in our department, including 34 males and 10 females, with an average age of 59.84 ± 11.72 years. Three aortic arch branches were affected in all patients. A 3D-printed model was made according to computed tomography angiography images and used to guide the fabrication of PMSGs. All patients were followed up.</p><p><strong>Results: </strong>A total of 132 branches were successfully reconstructed with no case of conversion to open surgery. The average operation time was 4.97 ± 1.40 hours, including a mean 44.05 ± 7.72 minutes for stent-graft customization, the mean postoperative hospitalization duration was 9.91 ± 4.47 days, the average intraoperative blood loss was 480.91 mL (100-2810 mL), and the mean postoperative intensive care unit monitoring duration was 1.02 days (0-5 days). No deaths occurred within 30 days of surgery. Postoperative neurological complications occurred in 1 case (2.3%), and retrograde type A dissection occurred in 1 case (2.3%).</p><p><strong>Conclusion: </strong>Compared with conventional surgery, triple aortic arch branch reconstruction under the guidance of 3D printing is a minimally invasive treatment method with the advantages of accurate positioning, rapid postoperative recovery, few complications, and reliable short- to mid-term effects.</p><p><strong>Clinical impact: </strong>At present the PMSG usually depend on imaging data and software calculation. With the guidance of 3D printing technology, image data could be transformed into 3D model, which has improved the accuracy of the positioning of the fenestrations. The diameter reduction technique and the internal mini cuff technique have made a complement to the slimed-down fenestration selection process and the low rate of endoleak. As reproducible study, our results may provide reference for TEVAR in different cases.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":" ","pages":"1088-1097"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-Dimensional Printing to Guide Fenestrated/Branched TEVAR in Triple Aortic Arch Branch Reconstruction With a Curative Effect Analysis.\",\"authors\":\"Dong-Sheng Fu, Yi Jin, Zi-He Zhao, Chao Wang, Ying-Huan Shi, Ming-Jie Zhou, Jing-Xiong Zhao, Chen Liu, Tong Qiao, Chang-Jian Liu, Xiao-Qiang Li, Wen-Dong Li, Zhao Liu\",\"doi\":\"10.1177/15266028231161244\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To summarize experience with and the efficacy of fenestrated/branched thoracic endovascular repair (F/B-TEVAR) using physician-modified stent-grafts (PMSGs) under 3D printing guidance in triple aortic arch branch reconstruction.</p><p><strong>Materials and methods: </strong>From February 2018 to April 2022, 14 cases of aortic arch aneurysms and 30 cases of aortic arch dissection (22 acute aortic arch dissection and 8 long-term aortic arch dissection)were treated by F/B-TEVAR in our department, including 34 males and 10 females, with an average age of 59.84 ± 11.72 years. Three aortic arch branches were affected in all patients. A 3D-printed model was made according to computed tomography angiography images and used to guide the fabrication of PMSGs. All patients were followed up.</p><p><strong>Results: </strong>A total of 132 branches were successfully reconstructed with no case of conversion to open surgery. The average operation time was 4.97 ± 1.40 hours, including a mean 44.05 ± 7.72 minutes for stent-graft customization, the mean postoperative hospitalization duration was 9.91 ± 4.47 days, the average intraoperative blood loss was 480.91 mL (100-2810 mL), and the mean postoperative intensive care unit monitoring duration was 1.02 days (0-5 days). No deaths occurred within 30 days of surgery. Postoperative neurological complications occurred in 1 case (2.3%), and retrograde type A dissection occurred in 1 case (2.3%).</p><p><strong>Conclusion: </strong>Compared with conventional surgery, triple aortic arch branch reconstruction under the guidance of 3D printing is a minimally invasive treatment method with the advantages of accurate positioning, rapid postoperative recovery, few complications, and reliable short- to mid-term effects.</p><p><strong>Clinical impact: </strong>At present the PMSG usually depend on imaging data and software calculation. With the guidance of 3D printing technology, image data could be transformed into 3D model, which has improved the accuracy of the positioning of the fenestrations. The diameter reduction technique and the internal mini cuff technique have made a complement to the slimed-down fenestration selection process and the low rate of endoleak. As reproducible study, our results may provide reference for TEVAR in different cases.</p>\",\"PeriodicalId\":50210,\"journal\":{\"name\":\"Journal of Endovascular Therapy\",\"volume\":\" \",\"pages\":\"1088-1097\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Endovascular Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15266028231161244\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/3/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028231161244","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

目的:总结在3D打印引导下使用医生改良支架移植物(PMSGs)进行主动脉弓三分支重建的开窗/分支胸腔内血管修复(F/B-TEVAR)的经验和疗效:2018年2月至2022年4月,我科采用F/B-TEVAR治疗主动脉弓动脉瘤14例,主动脉弓夹层30例(急性主动脉弓夹层22例,长期主动脉弓夹层8例),其中男性34例,女性10例,平均年龄(59.84±11.72)岁。所有患者均有三个主动脉弓分支受累。根据计算机断层扫描血管造影图像制作了一个 3D 打印模型,用于指导 PMSG 的制作。对所有患者进行了随访:结果:共成功重建了 132 个分支,无一例转为开放手术。平均手术时间为(4.97±1.40)小时,其中支架移植物定制平均时间为(44.05±7.72)分钟,术后平均住院时间为(9.91±4.47)天,术中平均失血量为 480.91 毫升(100-2810 毫升),术后重症监护室平均监护时间为 1.02 天(0-5 天)。术后30天内无死亡病例。1例(2.3%)发生术后神经并发症,1例(2.3%)发生逆行A型夹层:与传统手术相比,3D打印引导下的主动脉弓三支重建术是一种微创治疗方法,具有定位准确、术后恢复快、并发症少、中短期疗效可靠等优点:临床影响:目前,PMSG 通常依赖于影像数据和软件计算。临床影响:目前,PMSG 通常依赖于影像数据和软件计算,而在 3D 打印技术的指导下,影像数据可以转化为 3D 模型,从而提高了瓣膜定位的准确性。直径缩小技术和内迷你袖带技术对纤细化瘘管选择过程和低内漏率起到了补充作用。作为一项可重复的研究,我们的结果可为不同病例的 TEVAR 提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Three-Dimensional Printing to Guide Fenestrated/Branched TEVAR in Triple Aortic Arch Branch Reconstruction With a Curative Effect Analysis.

Purpose: To summarize experience with and the efficacy of fenestrated/branched thoracic endovascular repair (F/B-TEVAR) using physician-modified stent-grafts (PMSGs) under 3D printing guidance in triple aortic arch branch reconstruction.

Materials and methods: From February 2018 to April 2022, 14 cases of aortic arch aneurysms and 30 cases of aortic arch dissection (22 acute aortic arch dissection and 8 long-term aortic arch dissection)were treated by F/B-TEVAR in our department, including 34 males and 10 females, with an average age of 59.84 ± 11.72 years. Three aortic arch branches were affected in all patients. A 3D-printed model was made according to computed tomography angiography images and used to guide the fabrication of PMSGs. All patients were followed up.

Results: A total of 132 branches were successfully reconstructed with no case of conversion to open surgery. The average operation time was 4.97 ± 1.40 hours, including a mean 44.05 ± 7.72 minutes for stent-graft customization, the mean postoperative hospitalization duration was 9.91 ± 4.47 days, the average intraoperative blood loss was 480.91 mL (100-2810 mL), and the mean postoperative intensive care unit monitoring duration was 1.02 days (0-5 days). No deaths occurred within 30 days of surgery. Postoperative neurological complications occurred in 1 case (2.3%), and retrograde type A dissection occurred in 1 case (2.3%).

Conclusion: Compared with conventional surgery, triple aortic arch branch reconstruction under the guidance of 3D printing is a minimally invasive treatment method with the advantages of accurate positioning, rapid postoperative recovery, few complications, and reliable short- to mid-term effects.

Clinical impact: At present the PMSG usually depend on imaging data and software calculation. With the guidance of 3D printing technology, image data could be transformed into 3D model, which has improved the accuracy of the positioning of the fenestrations. The diameter reduction technique and the internal mini cuff technique have made a complement to the slimed-down fenestration selection process and the low rate of endoleak. As reproducible study, our results may provide reference for TEVAR in different cases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.30
自引率
15.40%
发文量
203
审稿时长
6-12 weeks
期刊介绍: The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.
期刊最新文献
The Value of Different Systemic Inflammatory Response Indicators in the Long-term Prognosis of Type B Aortic Dissection Patients Undergoing Thoracic Endovascular Aortic Repair. Effect of Statins on the Prognosis After Thoracic Endovascular Aortic Repair for Patients With Acute Type B Aortic Dissection. Potential of D-Dimer as a Tool to Rule Out Sac Expansion in Patients With Persistent Type 2 Endoleaks After Endovascular Aneurysm Repair. Long-Term Outcomes and Late Complications of Thoracic Endovascular Aortic Repair Using the GORE TAG or Conformable GORE TAG. Long-term Outcomes of the AcoArt II-BTK Trial: Drug-Coated Balloon Angioplasty Compared With Uncoated Balloons for the Treatment of Infrapopliteal Artery Lesions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1