2010-2020 年甲状腺切除术中与能量设备相关的并发症。

Q2 Medicine World Journal of OtorhinolaryngologyHead and Neck Surgery Pub Date : 2022-04-28 eCollection Date: 2023-03-01 DOI:10.1016/j.wjorl.2021.04.008
Esther Lee, Jane Y Tong, Luke J Pasick, Daniel A Benito, Arjun Joshi, Punam G Thakkar, Joseph F Goodman
{"title":"2010-2020 年甲状腺切除术中与能量设备相关的并发症。","authors":"Esther Lee, Jane Y Tong, Luke J Pasick, Daniel A Benito, Arjun Joshi, Punam G Thakkar, Joseph F Goodman","doi":"10.1016/j.wjorl.2021.04.008","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Harmonic Focus (Ethicon, Johnson and Johnson, Cincinnati, OH, USA), LigaSure Small Jaw (Medtronic, Covidien Products, Minneapolis, MN, USA), and Thunderbeat Open Fine Jaw (Olympus, Japan) are electrosurgical instruments used widely in head and neck surgery. The study aims to compare device malfunctions, adverse events to patients, operative injuries, and interventions related to Harmonic, LigaSure, and Thunderbeat use during thyroidectomy.</p><p><strong>Methods: </strong>The US Food and Drug Administration's Manufacture and User Facility Device Experience (MAUDE) database was queried for adverse events associated with Harmonic, LigaSure, and Thunderbeat from January 2005 to August 2020. Data were extracted from reports pertaining to thyroidectomy.</p><p><strong>Results: </strong>Of the 620 adverse events extracted, 394 (63.5%) involved Harmonic, 134 (21.6%) LigaSure, and 92 (14.8%) Thunderbeat. The reported device malfunctions most frequently associated with Harmonic was damage to the blade (110 (27.9%)), LigaSure was inappropriate function (47 (43.1%)), Thunderbeat was damage to the tissue or Teflon pad (27 (30.7%)), respectively. Burn injury and incomplete hemostasis were the most commonly reported adverse events. The operative injury reported most frequently when using Harmonic and LigaSure was burn injury. No operator injuries were reported with Thunderbeat use.</p><p><strong>Conclusion: </strong>The most frequently reported device malfunctions were damage to the blade, inappropriate function, and damage to the tissue or Teflon pad. The most frequently reported adverse events to patients was a burn injury and incomplete hemostasis. Interventions aimed at improving physician education may help reduce adverse events attributed to improper use.</p>","PeriodicalId":32097,"journal":{"name":"World Journal of OtorhinolaryngologyHead and Neck Surgery","volume":"9 1","pages":"35-44"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ee/77/WJO2-9-35.PMC10050967.pdf","citationCount":"0","resultStr":"{\"title\":\"Complications associated with energy-based devices during thyroidectomy from 2010-2020.\",\"authors\":\"Esther Lee, Jane Y Tong, Luke J Pasick, Daniel A Benito, Arjun Joshi, Punam G Thakkar, Joseph F Goodman\",\"doi\":\"10.1016/j.wjorl.2021.04.008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Harmonic Focus (Ethicon, Johnson and Johnson, Cincinnati, OH, USA), LigaSure Small Jaw (Medtronic, Covidien Products, Minneapolis, MN, USA), and Thunderbeat Open Fine Jaw (Olympus, Japan) are electrosurgical instruments used widely in head and neck surgery. The study aims to compare device malfunctions, adverse events to patients, operative injuries, and interventions related to Harmonic, LigaSure, and Thunderbeat use during thyroidectomy.</p><p><strong>Methods: </strong>The US Food and Drug Administration's Manufacture and User Facility Device Experience (MAUDE) database was queried for adverse events associated with Harmonic, LigaSure, and Thunderbeat from January 2005 to August 2020. Data were extracted from reports pertaining to thyroidectomy.</p><p><strong>Results: </strong>Of the 620 adverse events extracted, 394 (63.5%) involved Harmonic, 134 (21.6%) LigaSure, and 92 (14.8%) Thunderbeat. The reported device malfunctions most frequently associated with Harmonic was damage to the blade (110 (27.9%)), LigaSure was inappropriate function (47 (43.1%)), Thunderbeat was damage to the tissue or Teflon pad (27 (30.7%)), respectively. Burn injury and incomplete hemostasis were the most commonly reported adverse events. The operative injury reported most frequently when using Harmonic and LigaSure was burn injury. No operator injuries were reported with Thunderbeat use.</p><p><strong>Conclusion: </strong>The most frequently reported device malfunctions were damage to the blade, inappropriate function, and damage to the tissue or Teflon pad. The most frequently reported adverse events to patients was a burn injury and incomplete hemostasis. Interventions aimed at improving physician education may help reduce adverse events attributed to improper use.</p>\",\"PeriodicalId\":32097,\"journal\":{\"name\":\"World Journal of OtorhinolaryngologyHead and Neck Surgery\",\"volume\":\"9 1\",\"pages\":\"35-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ee/77/WJO2-9-35.PMC10050967.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World Journal of OtorhinolaryngologyHead and Neck Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.wjorl.2021.04.008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/3/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of OtorhinolaryngologyHead and Neck Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.wjorl.2021.04.008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:Harmonic Focus(Ethicon,强生公司,美国俄亥俄州辛辛那提市)、LigaSure Small Jaw(美敦力公司,Covidien Products,美国明尼阿波利斯市)和 Thunderbeat Open Fine Jaw(奥林巴斯公司,日本)是头颈部手术中广泛使用的电外科器械。本研究旨在比较甲状腺切除术中使用 Harmonic、LigaSure 和 Thunderbeat 时发生的器械故障、对患者造成的不良事件、手术伤害和干预措施:对美国食品和药物管理局的生产和用户设施设备经验(MAUDE)数据库进行了查询,以了解2005年1月至2020年8月期间与Harmonic、LigaSure和Thunderbeat相关的不良事件。数据提取自甲状腺切除术的相关报告:在提取的 620 例不良事件中,394 例(63.5%)涉及 Harmonic,134 例(21.6%)涉及 LigaSure,92 例(14.8%)涉及 Thunderbeat。Harmonic 最常见的设备故障是刀片损坏(110 例(27.9%)),LigaSure 最常见的故障是功能不当(47 例(43.1%)),Thunderbeat 最常见的故障是组织或特氟龙垫损坏(27 例(30.7%))。烧伤和止血不完全是最常报告的不良事件。使用 Harmonic 和 LigaSure 时最常报告的手术损伤是烧伤。使用 Thunderbeat 时没有操作者受伤的报告:结论:最常报告的设备故障是刀片损坏、功能不当、组织或特氟龙垫损坏。患者最常报告的不良事件是烧伤和止血不全。旨在加强医生教育的干预措施可能有助于减少因使用不当而导致的不良事件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Complications associated with energy-based devices during thyroidectomy from 2010-2020.

Objective: Harmonic Focus (Ethicon, Johnson and Johnson, Cincinnati, OH, USA), LigaSure Small Jaw (Medtronic, Covidien Products, Minneapolis, MN, USA), and Thunderbeat Open Fine Jaw (Olympus, Japan) are electrosurgical instruments used widely in head and neck surgery. The study aims to compare device malfunctions, adverse events to patients, operative injuries, and interventions related to Harmonic, LigaSure, and Thunderbeat use during thyroidectomy.

Methods: The US Food and Drug Administration's Manufacture and User Facility Device Experience (MAUDE) database was queried for adverse events associated with Harmonic, LigaSure, and Thunderbeat from January 2005 to August 2020. Data were extracted from reports pertaining to thyroidectomy.

Results: Of the 620 adverse events extracted, 394 (63.5%) involved Harmonic, 134 (21.6%) LigaSure, and 92 (14.8%) Thunderbeat. The reported device malfunctions most frequently associated with Harmonic was damage to the blade (110 (27.9%)), LigaSure was inappropriate function (47 (43.1%)), Thunderbeat was damage to the tissue or Teflon pad (27 (30.7%)), respectively. Burn injury and incomplete hemostasis were the most commonly reported adverse events. The operative injury reported most frequently when using Harmonic and LigaSure was burn injury. No operator injuries were reported with Thunderbeat use.

Conclusion: The most frequently reported device malfunctions were damage to the blade, inappropriate function, and damage to the tissue or Teflon pad. The most frequently reported adverse events to patients was a burn injury and incomplete hemostasis. Interventions aimed at improving physician education may help reduce adverse events attributed to improper use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
283
审稿时长
13 weeks
期刊最新文献
Author Guidelines. Author Guidelines. Long COVID: From olfactory dysfunctions to viral Parkinsonism. Author Guidelines. Epidemiological and histopathological characteristics of thyroid carcinoma in a Tunisian health care center.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1