{"title":"胫神经sep在腰椎管狭窄诊断中的应用:应用P15和N21进行节段性评价","authors":"Kiyoshi Matsukura , Keiichi Hokkoku , Taiji Mukai , Chizuko Oishi , Takamichi Kanbayashi , Toshiyuki Takahashi , Masahiro Sonoo","doi":"10.1016/j.cnp.2023.03.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>To establish the utility of the additional evaluation of the P15 potential generated at the greater sciatic foramen in the tibial nerve somatosensory evoked potentials (SEPs) in diagnosing lumbar spinal stenosis (LSS).</p></div><div><h3>Methods</h3><p>We retrospectively reviewed tibial nerve SEP findings in patients having MRI-confirmed LSS at the cauda equina or conus/epiconus region. P15 and N21 potentials were recorded and the following findings were defined as localizing abnormalities: 1) normal P15 latency either with prolonged P15-N21 interval or with absent N21; 2) decreased ratio of the N21 amplitude to P15 amplitude. As non-localizing abnormalities, N21 and P38 latencies were also evaluated. Tibial nerve F-wave findings were also investigated.</p></div><div><h3>Results</h3><p>According to the entry criteria, 18 patients were included, 15 with cauda equina lesions and 3 with conus/epiconus lesions. Localizing abnormalities in SEPs were found in 67% of patients, achieving significantly higher sensitivity than delayed P38 latency (28%), and higher sensitivity than N21 abnormalities (39%), though this was not significant. Localizing abnormalities were observed even in 6 out of 11 patients lacking both sensory symptoms and signs. Tibial nerve F-wave was abnormal in 36% of 14 patients with F-wave examinations, whereas the localizing abnormalities in SEPs were found in 64% of the same patient population. P15 amplitude was depressed in 4 patients (22%), which may indicate the involvement of the dorsal root ganglion in LSS, although its latency was normal even for these patients.</p></div><div><h3>Conclusions</h3><p>Tibial nerve SEPs with the recording of P15 and N21 potentials achieved sufficiently high sensitivity in diagnosing LSS. They have the advantage over F-wave in that they can localize the lesion at the cauda equina or conus/epiconus level.</p></div><div><h3>Significance</h3><p>Tibial nerve SEPs are promising in evaluating LSS, especially in documenting sensory tract involvement in cases lacking sensory symptoms/signs.</p></div>","PeriodicalId":45697,"journal":{"name":"Clinical Neurophysiology Practice","volume":"8 ","pages":"Pages 49-57"},"PeriodicalIF":2.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064344/pdf/main.pdf","citationCount":"1","resultStr":"{\"title\":\"Tibial nerve SEPs in diagnosing lumbar spinal stenosis: The utility of segmental evaluation using P15 and N21\",\"authors\":\"Kiyoshi Matsukura , Keiichi Hokkoku , Taiji Mukai , Chizuko Oishi , Takamichi Kanbayashi , Toshiyuki Takahashi , Masahiro Sonoo\",\"doi\":\"10.1016/j.cnp.2023.03.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>To establish the utility of the additional evaluation of the P15 potential generated at the greater sciatic foramen in the tibial nerve somatosensory evoked potentials (SEPs) in diagnosing lumbar spinal stenosis (LSS).</p></div><div><h3>Methods</h3><p>We retrospectively reviewed tibial nerve SEP findings in patients having MRI-confirmed LSS at the cauda equina or conus/epiconus region. P15 and N21 potentials were recorded and the following findings were defined as localizing abnormalities: 1) normal P15 latency either with prolonged P15-N21 interval or with absent N21; 2) decreased ratio of the N21 amplitude to P15 amplitude. As non-localizing abnormalities, N21 and P38 latencies were also evaluated. Tibial nerve F-wave findings were also investigated.</p></div><div><h3>Results</h3><p>According to the entry criteria, 18 patients were included, 15 with cauda equina lesions and 3 with conus/epiconus lesions. Localizing abnormalities in SEPs were found in 67% of patients, achieving significantly higher sensitivity than delayed P38 latency (28%), and higher sensitivity than N21 abnormalities (39%), though this was not significant. Localizing abnormalities were observed even in 6 out of 11 patients lacking both sensory symptoms and signs. Tibial nerve F-wave was abnormal in 36% of 14 patients with F-wave examinations, whereas the localizing abnormalities in SEPs were found in 64% of the same patient population. P15 amplitude was depressed in 4 patients (22%), which may indicate the involvement of the dorsal root ganglion in LSS, although its latency was normal even for these patients.</p></div><div><h3>Conclusions</h3><p>Tibial nerve SEPs with the recording of P15 and N21 potentials achieved sufficiently high sensitivity in diagnosing LSS. They have the advantage over F-wave in that they can localize the lesion at the cauda equina or conus/epiconus level.</p></div><div><h3>Significance</h3><p>Tibial nerve SEPs are promising in evaluating LSS, especially in documenting sensory tract involvement in cases lacking sensory symptoms/signs.</p></div>\",\"PeriodicalId\":45697,\"journal\":{\"name\":\"Clinical Neurophysiology Practice\",\"volume\":\"8 \",\"pages\":\"Pages 49-57\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064344/pdf/main.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Neurophysiology Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2467981X23000033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neurophysiology Practice","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2467981X23000033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
Tibial nerve SEPs in diagnosing lumbar spinal stenosis: The utility of segmental evaluation using P15 and N21
Objective
To establish the utility of the additional evaluation of the P15 potential generated at the greater sciatic foramen in the tibial nerve somatosensory evoked potentials (SEPs) in diagnosing lumbar spinal stenosis (LSS).
Methods
We retrospectively reviewed tibial nerve SEP findings in patients having MRI-confirmed LSS at the cauda equina or conus/epiconus region. P15 and N21 potentials were recorded and the following findings were defined as localizing abnormalities: 1) normal P15 latency either with prolonged P15-N21 interval or with absent N21; 2) decreased ratio of the N21 amplitude to P15 amplitude. As non-localizing abnormalities, N21 and P38 latencies were also evaluated. Tibial nerve F-wave findings were also investigated.
Results
According to the entry criteria, 18 patients were included, 15 with cauda equina lesions and 3 with conus/epiconus lesions. Localizing abnormalities in SEPs were found in 67% of patients, achieving significantly higher sensitivity than delayed P38 latency (28%), and higher sensitivity than N21 abnormalities (39%), though this was not significant. Localizing abnormalities were observed even in 6 out of 11 patients lacking both sensory symptoms and signs. Tibial nerve F-wave was abnormal in 36% of 14 patients with F-wave examinations, whereas the localizing abnormalities in SEPs were found in 64% of the same patient population. P15 amplitude was depressed in 4 patients (22%), which may indicate the involvement of the dorsal root ganglion in LSS, although its latency was normal even for these patients.
Conclusions
Tibial nerve SEPs with the recording of P15 and N21 potentials achieved sufficiently high sensitivity in diagnosing LSS. They have the advantage over F-wave in that they can localize the lesion at the cauda equina or conus/epiconus level.
Significance
Tibial nerve SEPs are promising in evaluating LSS, especially in documenting sensory tract involvement in cases lacking sensory symptoms/signs.
期刊介绍:
Clinical Neurophysiology Practice (CNP) is a new Open Access journal that focuses on clinical practice issues in clinical neurophysiology including relevant new research, case reports or clinical series, normal values and didactic reviews. It is an official journal of the International Federation of Clinical Neurophysiology and complements Clinical Neurophysiology which focuses on innovative research in the specialty. It has a role in supporting established clinical practice, and an educational role for trainees, technicians and practitioners.