{"title":"载BMP-2功能纳米颗粒浸渍聚对苯二甲酸乙二醇酯(PET)移植物重建前交叉韧带。","authors":"Zeynep Karahaliloglu, Batur Ercan, Baki Hazer","doi":"10.1080/02652048.2023.2188940","DOIUrl":null,"url":null,"abstract":"<p><p>Current artificial ligaments based on polyethylene terephthalate (PET) are associated with some disadvantages due to their hydrophobicity and low biocompatibility. In this study, we aimed to modify the surface of PET using polyethylene glycol (PEG)-terminated polystyrene (PS)-linoleic nanoparticles (PLinaS-g-PEG-NPs). We accomplished that BMP-2 in two different concentrations encapsulated in nanoparticles with an efficiency of 99.71 ± 1.5 and 99.95 ± 2.8%. While the dynamic contact angle of plain PET surface reduced from 116° to 115° after a measurement periods of 10 s, that of PLinaS-g-PEG-NPs modified PET from 80° to 17.5° within 0.35 s. According to <i>in vitro</i> BMP2 release study, BMP-2 was released 13.12 ± 1.76% and 45.47 ± 1.78% from 0.05 and 0.1BMP2-PLinaS-g-PEG-NPs modified PET at the end of 20 days, respectively. Findings from this study revealed that BMP2-PLinaS-g-PEG-NPs has a great potential to improve the artificial PET ligaments, and could be effectively applied for ACL reconstruction.</p>","PeriodicalId":16391,"journal":{"name":"Journal of microencapsulation","volume":"40 3","pages":"197-215"},"PeriodicalIF":3.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impregnation of polyethylene terephthalate (PET) grafts with BMP-2 loaded functional nanoparticles for reconstruction of anterior cruciate ligament.\",\"authors\":\"Zeynep Karahaliloglu, Batur Ercan, Baki Hazer\",\"doi\":\"10.1080/02652048.2023.2188940\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Current artificial ligaments based on polyethylene terephthalate (PET) are associated with some disadvantages due to their hydrophobicity and low biocompatibility. In this study, we aimed to modify the surface of PET using polyethylene glycol (PEG)-terminated polystyrene (PS)-linoleic nanoparticles (PLinaS-g-PEG-NPs). We accomplished that BMP-2 in two different concentrations encapsulated in nanoparticles with an efficiency of 99.71 ± 1.5 and 99.95 ± 2.8%. While the dynamic contact angle of plain PET surface reduced from 116° to 115° after a measurement periods of 10 s, that of PLinaS-g-PEG-NPs modified PET from 80° to 17.5° within 0.35 s. According to <i>in vitro</i> BMP2 release study, BMP-2 was released 13.12 ± 1.76% and 45.47 ± 1.78% from 0.05 and 0.1BMP2-PLinaS-g-PEG-NPs modified PET at the end of 20 days, respectively. Findings from this study revealed that BMP2-PLinaS-g-PEG-NPs has a great potential to improve the artificial PET ligaments, and could be effectively applied for ACL reconstruction.</p>\",\"PeriodicalId\":16391,\"journal\":{\"name\":\"Journal of microencapsulation\",\"volume\":\"40 3\",\"pages\":\"197-215\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of microencapsulation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/02652048.2023.2188940\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of microencapsulation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02652048.2023.2188940","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
Impregnation of polyethylene terephthalate (PET) grafts with BMP-2 loaded functional nanoparticles for reconstruction of anterior cruciate ligament.
Current artificial ligaments based on polyethylene terephthalate (PET) are associated with some disadvantages due to their hydrophobicity and low biocompatibility. In this study, we aimed to modify the surface of PET using polyethylene glycol (PEG)-terminated polystyrene (PS)-linoleic nanoparticles (PLinaS-g-PEG-NPs). We accomplished that BMP-2 in two different concentrations encapsulated in nanoparticles with an efficiency of 99.71 ± 1.5 and 99.95 ± 2.8%. While the dynamic contact angle of plain PET surface reduced from 116° to 115° after a measurement periods of 10 s, that of PLinaS-g-PEG-NPs modified PET from 80° to 17.5° within 0.35 s. According to in vitro BMP2 release study, BMP-2 was released 13.12 ± 1.76% and 45.47 ± 1.78% from 0.05 and 0.1BMP2-PLinaS-g-PEG-NPs modified PET at the end of 20 days, respectively. Findings from this study revealed that BMP2-PLinaS-g-PEG-NPs has a great potential to improve the artificial PET ligaments, and could be effectively applied for ACL reconstruction.
期刊介绍:
The Journal of Microencapsulation is a well-established, peer-reviewed journal dedicated to the publication of original research findings related to the preparation, properties and uses of individually encapsulated novel small particles, as well as significant improvements to tried-and-tested techniques relevant to micro and nano particles and their use in a wide variety of industrial, engineering, pharmaceutical, biotechnology and research applications. Its scope extends beyond conventional microcapsules to all other small particulate systems such as self assembling structures that involve preparative manipulation.
The journal covers:
Chemistry of encapsulation materials
Physics of release through the capsule wall and/or desorption from carrier
Techniques of preparation, content and storage
Many uses to which microcapsules are put.