{"title":"用二维斑点跟踪超声心动图评估猫心源性和非心源性动脉血栓栓塞的左心房心肌变形。","authors":"Jidapa Tosuwan, Sirilak Disatian Surachetpong, Vachira Hunprasit","doi":"10.1080/23144599.2023.2196853","DOIUrl":null,"url":null,"abstract":"<p><p>Arterial thromboembolism (ATE) in cats usually relates to cardiogenic causes that can be diagnosed by conventional echocardiography. Two-dimensional speckle-tracking echocardiography (2D-STE) is a new ultrasound modality with higher sensitivity. Our objective was to investigate left atrial myocardial deformation in cats with both cardiogenic and non-cardiogenic ATE and normal cats using 2D-STE. Twenty-three normal cats and 21 cats with ATE cats were recruited and performed conventional echocardiography and 2D-STE. From the results, left atrial (LA) strain and strain rate from 2D-STE were significantly decreased in cats with cardiogenic ATE (<i>P</i> < 0.001), but there was no significant difference in non-cardiogenic ATE compared with normal cats. From the correlation test, the use of left atrial strain during the reservoir phase (LASr) could represent the overall LA deformation. The intra- and inter-observer coefficient of variation of LASr was less than 15%. The logistic regression revealed that the LASr value of less than 11% was a significant factor for the occurrence of ATE (odd ratio = 189.0, <i>P</i> < 0.001). In conclusion, LASr derived by 2D-STE is a repeatable and non-invasive technique to assess LA myocardial deformation in cats with ATE. By 2D-STE, impaired LA function was detected in cats with cardiogenic ATE. LASr < 11% may use as a predictor of the risk of ATE occurrence in cats.</p>","PeriodicalId":45744,"journal":{"name":"International Journal of Veterinary Science and Medicine","volume":"11 1","pages":"11-22"},"PeriodicalIF":2.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10071954/pdf/","citationCount":"1","resultStr":"{\"title\":\"Assessment of left atrial myocardial deformation using two-dimensional speckle-tracking echocardiography in cats with cardiogenic and non-cardiogenic arterial thromboembolism.\",\"authors\":\"Jidapa Tosuwan, Sirilak Disatian Surachetpong, Vachira Hunprasit\",\"doi\":\"10.1080/23144599.2023.2196853\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Arterial thromboembolism (ATE) in cats usually relates to cardiogenic causes that can be diagnosed by conventional echocardiography. Two-dimensional speckle-tracking echocardiography (2D-STE) is a new ultrasound modality with higher sensitivity. Our objective was to investigate left atrial myocardial deformation in cats with both cardiogenic and non-cardiogenic ATE and normal cats using 2D-STE. Twenty-three normal cats and 21 cats with ATE cats were recruited and performed conventional echocardiography and 2D-STE. From the results, left atrial (LA) strain and strain rate from 2D-STE were significantly decreased in cats with cardiogenic ATE (<i>P</i> < 0.001), but there was no significant difference in non-cardiogenic ATE compared with normal cats. From the correlation test, the use of left atrial strain during the reservoir phase (LASr) could represent the overall LA deformation. The intra- and inter-observer coefficient of variation of LASr was less than 15%. The logistic regression revealed that the LASr value of less than 11% was a significant factor for the occurrence of ATE (odd ratio = 189.0, <i>P</i> < 0.001). In conclusion, LASr derived by 2D-STE is a repeatable and non-invasive technique to assess LA myocardial deformation in cats with ATE. By 2D-STE, impaired LA function was detected in cats with cardiogenic ATE. LASr < 11% may use as a predictor of the risk of ATE occurrence in cats.</p>\",\"PeriodicalId\":45744,\"journal\":{\"name\":\"International Journal of Veterinary Science and Medicine\",\"volume\":\"11 1\",\"pages\":\"11-22\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10071954/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Veterinary Science and Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/23144599.2023.2196853\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Veterinary Science and Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/23144599.2023.2196853","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 1
摘要
猫的动脉血栓栓塞(ATE)通常与心源性原因有关,可通过常规超声心动图诊断。二维斑点跟踪超声心动图(2D-STE)是一种灵敏度较高的新型超声方式。我们的目的是利用2D-STE研究患有心源性和非心源性ATE的猫和正常猫的左心房心肌变形。选取23只正常猫和21只ATE猫,进行常规超声心动图和2D-STE检查。结果显示,心源性ATE (P P P)猫左心房(LA)应变和2D-STE应变率显著降低
Assessment of left atrial myocardial deformation using two-dimensional speckle-tracking echocardiography in cats with cardiogenic and non-cardiogenic arterial thromboembolism.
Arterial thromboembolism (ATE) in cats usually relates to cardiogenic causes that can be diagnosed by conventional echocardiography. Two-dimensional speckle-tracking echocardiography (2D-STE) is a new ultrasound modality with higher sensitivity. Our objective was to investigate left atrial myocardial deformation in cats with both cardiogenic and non-cardiogenic ATE and normal cats using 2D-STE. Twenty-three normal cats and 21 cats with ATE cats were recruited and performed conventional echocardiography and 2D-STE. From the results, left atrial (LA) strain and strain rate from 2D-STE were significantly decreased in cats with cardiogenic ATE (P < 0.001), but there was no significant difference in non-cardiogenic ATE compared with normal cats. From the correlation test, the use of left atrial strain during the reservoir phase (LASr) could represent the overall LA deformation. The intra- and inter-observer coefficient of variation of LASr was less than 15%. The logistic regression revealed that the LASr value of less than 11% was a significant factor for the occurrence of ATE (odd ratio = 189.0, P < 0.001). In conclusion, LASr derived by 2D-STE is a repeatable and non-invasive technique to assess LA myocardial deformation in cats with ATE. By 2D-STE, impaired LA function was detected in cats with cardiogenic ATE. LASr < 11% may use as a predictor of the risk of ATE occurrence in cats.