透视下取出嵌入食管自扩张金属支架:支架内支架联合导丝套索技术。

IF 1.1 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS Annals of Thoracic and Cardiovascular Surgery Pub Date : 2023-04-20 DOI:10.5761/atcs.cr.21-00120
Yonghua Bi, Hongmei Chen, Wenguang Zhang, Xinwei Han, Jianzhuang Ren
{"title":"透视下取出嵌入食管自扩张金属支架:支架内支架联合导丝套索技术。","authors":"Yonghua Bi,&nbsp;Hongmei Chen,&nbsp;Wenguang Zhang,&nbsp;Xinwei Han,&nbsp;Jianzhuang Ren","doi":"10.5761/atcs.cr.21-00120","DOIUrl":null,"url":null,"abstract":"<p><p>We report the use of the guidewire lasso technique for the removal of an embedded esophageal self-expanding metal stent (SEMS), following a failure of distal to proximal invagination by removal hook caused by stent incorporation. During a removal procedure of an embedded SEMS using the hook retrieval device, the strut fractured and the stent retained. Attempts to pull up the retained stent using hook were not effective. Thus, the lasso technique with a guidewire over the retained stent was performed and successfully removed with no procedure-related complications. The patient is alive without dysphagia after 3 months follow-up.</p>","PeriodicalId":8037,"journal":{"name":"Annals of Thoracic and Cardiovascular Surgery","volume":"29 2","pages":"93-96"},"PeriodicalIF":1.1000,"publicationDate":"2023-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d9/37/atcs-29-093.PMC10126766.pdf","citationCount":"1","resultStr":"{\"title\":\"Fluoroscopic Removal of Embedded Esophageal Self-Expanding Metal Stents: Stent-in-Stent Combined with Guidewire Lasso Technique.\",\"authors\":\"Yonghua Bi,&nbsp;Hongmei Chen,&nbsp;Wenguang Zhang,&nbsp;Xinwei Han,&nbsp;Jianzhuang Ren\",\"doi\":\"10.5761/atcs.cr.21-00120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We report the use of the guidewire lasso technique for the removal of an embedded esophageal self-expanding metal stent (SEMS), following a failure of distal to proximal invagination by removal hook caused by stent incorporation. During a removal procedure of an embedded SEMS using the hook retrieval device, the strut fractured and the stent retained. Attempts to pull up the retained stent using hook were not effective. Thus, the lasso technique with a guidewire over the retained stent was performed and successfully removed with no procedure-related complications. The patient is alive without dysphagia after 3 months follow-up.</p>\",\"PeriodicalId\":8037,\"journal\":{\"name\":\"Annals of Thoracic and Cardiovascular Surgery\",\"volume\":\"29 2\",\"pages\":\"93-96\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d9/37/atcs-29-093.PMC10126766.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Thoracic and Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5761/atcs.cr.21-00120\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5761/atcs.cr.21-00120","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 1

摘要

我们报告使用导丝套索技术去除嵌入的食管自扩张金属支架(SEMS),由于支架合并引起的远端到近端内陷失败,导致移除钩。在使用钩式回收装置移除嵌入式SEMS过程中,支架断裂,支架保留。尝试用钩将保留的支架拉起无效。因此,在保留的支架上使用导丝套索技术并成功移除,没有手术相关的并发症。随访3个月,患者存活,无吞咽困难。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fluoroscopic Removal of Embedded Esophageal Self-Expanding Metal Stents: Stent-in-Stent Combined with Guidewire Lasso Technique.

We report the use of the guidewire lasso technique for the removal of an embedded esophageal self-expanding metal stent (SEMS), following a failure of distal to proximal invagination by removal hook caused by stent incorporation. During a removal procedure of an embedded SEMS using the hook retrieval device, the strut fractured and the stent retained. Attempts to pull up the retained stent using hook were not effective. Thus, the lasso technique with a guidewire over the retained stent was performed and successfully removed with no procedure-related complications. The patient is alive without dysphagia after 3 months follow-up.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of Thoracic and Cardiovascular Surgery
Annals of Thoracic and Cardiovascular Surgery CARDIAC & CARDIOVASCULAR SYSTEMS-SURGERY
CiteScore
2.80
自引率
0.00%
发文量
56
审稿时长
4-8 weeks
期刊介绍: Information not localized
期刊最新文献
Arterial Embolization and Cone-Beam Computed Tomography-Guided Lung Resection for Anomalous Systemic Arterial Blood Supply to Normal Lung: Two Case Reports. Surgery for Ascending Aortic Aneurysm and Aortic Valve Insufficiency in Conditions of Active Proceeding Syphilitic Aortitis and Valvulitis. Impact of Graft Velocity on Saphenous Vein Graft Atherosclerosis after Coronary Artery Bypass Grafting. Surgery for Secondary Spontaneous Pneumothorax with Chronic Lung Diseases. Impact of Impella Support on Clinical Outcomes in Patients with Postcardiotomy Cardiogenic Shock.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1