{"title":"弹性成像在跟腱评估中的应用:测量特性的系统回顾。","authors":"Tiziana Mifsud,&nbsp;Alfred Gatt,&nbsp;Kirill Micallef-Stafrace,&nbsp;Nachiappan Chockalingam,&nbsp;Nat Padhiar","doi":"10.1186/s13047-023-00623-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Managing and rehabilitating Achilles tendinopathy can be difficult, and the results are often unsatisfactory. Currently, clinicians use ultrasonography to diagnose the condition and predict symptom development. However, relying on subjective qualitative findings using ultrasound images alone, which are heavily influenced by the operator, may make it difficult to identify changes within the tendon. New technologies, such as elastography, offer opportunities to quantitatively investigate the mechanical and material properties of the tendon. This review aims to evaluate and synthesise the current literature on the measurement properties of elastography, which can be used to assess tendon pathologies.</p><p><strong>Methods: </strong>A systematic review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. CINAHL, PubMed, Cochrane, Scopus, MEDLINE Complete, and Academic Search Ultimate were searched. Studies assessing the measurement properties concerning reliability, measurement error, validity, and responsiveness of the instruments identified in healthy and patients with Achilles tendinopathy were included. Two independent reviewers assessed the methodological quality using the Consensus-based Standards for the Selection of Health Measurement Instruments methodology.</p><p><strong>Results: </strong>Out of the 1644 articles identified, 21 were included for the qualitative analysis investigating four different modalities of elastography: axial strain elastography, shear wave elastography, continuous shear wave elastography, and 3D elastography. Axial strain elastography obtained a moderate level of evidence for both validity and reliability. Although shear wave velocity was graded as moderate to high for validity, reliability obtained a very low to moderate grading. Continuous shear wave elastography was graded as having a low level of evidence for reliability and very low for validity. Insufficient data is available to grade three-dimensional shear wave elastography. Evidence on measurement error was indeterminate so evidence could not be graded.</p><p><strong>Conclusions: </strong>A limited number of studies explored quantitative elastography on Achilles tendinopathy as most evidence was conducted on a healthy population. Based on the identified evidence on the measurement properties of elastography, none of the different types showed superiority for its use in clinical practice. Further high-quality studies with longitudinal design are needed to investigate responsiveness.</p>","PeriodicalId":49164,"journal":{"name":"Journal of Foot and Ankle Research","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10134611/pdf/","citationCount":"3","resultStr":"{\"title\":\"Elastography in the assessment of the Achilles tendon: a systematic review of measurement properties.\",\"authors\":\"Tiziana Mifsud,&nbsp;Alfred Gatt,&nbsp;Kirill Micallef-Stafrace,&nbsp;Nachiappan Chockalingam,&nbsp;Nat Padhiar\",\"doi\":\"10.1186/s13047-023-00623-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Managing and rehabilitating Achilles tendinopathy can be difficult, and the results are often unsatisfactory. Currently, clinicians use ultrasonography to diagnose the condition and predict symptom development. However, relying on subjective qualitative findings using ultrasound images alone, which are heavily influenced by the operator, may make it difficult to identify changes within the tendon. New technologies, such as elastography, offer opportunities to quantitatively investigate the mechanical and material properties of the tendon. This review aims to evaluate and synthesise the current literature on the measurement properties of elastography, which can be used to assess tendon pathologies.</p><p><strong>Methods: </strong>A systematic review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. CINAHL, PubMed, Cochrane, Scopus, MEDLINE Complete, and Academic Search Ultimate were searched. Studies assessing the measurement properties concerning reliability, measurement error, validity, and responsiveness of the instruments identified in healthy and patients with Achilles tendinopathy were included. Two independent reviewers assessed the methodological quality using the Consensus-based Standards for the Selection of Health Measurement Instruments methodology.</p><p><strong>Results: </strong>Out of the 1644 articles identified, 21 were included for the qualitative analysis investigating four different modalities of elastography: axial strain elastography, shear wave elastography, continuous shear wave elastography, and 3D elastography. Axial strain elastography obtained a moderate level of evidence for both validity and reliability. Although shear wave velocity was graded as moderate to high for validity, reliability obtained a very low to moderate grading. Continuous shear wave elastography was graded as having a low level of evidence for reliability and very low for validity. Insufficient data is available to grade three-dimensional shear wave elastography. Evidence on measurement error was indeterminate so evidence could not be graded.</p><p><strong>Conclusions: </strong>A limited number of studies explored quantitative elastography on Achilles tendinopathy as most evidence was conducted on a healthy population. Based on the identified evidence on the measurement properties of elastography, none of the different types showed superiority for its use in clinical practice. Further high-quality studies with longitudinal design are needed to investigate responsiveness.</p>\",\"PeriodicalId\":49164,\"journal\":{\"name\":\"Journal of Foot and Ankle Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2023-04-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10134611/pdf/\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Foot and Ankle Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13047-023-00623-1\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Foot and Ankle Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13047-023-00623-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 3

摘要

背景:跟腱病的治疗和康复是困难的,结果往往不令人满意。目前,临床医生使用超声检查来诊断病情并预测症状发展。然而,仅依靠超声图像的主观定性发现,这在很大程度上受操作者的影响,可能难以识别肌腱内的变化。新技术,如弹性成像,为定量研究肌腱的力学和材料特性提供了机会。本综述旨在评估和综合目前关于弹性成像测量特性的文献,弹性成像可用于评估肌腱病变。方法:根据系统评价和荟萃分析指南的首选报告项目进行系统评价。检索了CINAHL、PubMed、Cochrane、Scopus、MEDLINE Complete和Academic Search Ultimate。研究评估了在健康和跟腱病变患者中确定的仪器的测量特性,包括可靠性、测量误差、有效性和反应性。两名独立审稿人使用基于共识的健康测量工具选择标准方法评估了方法质量。结果:在鉴定的1644篇文章中,21篇被纳入定性分析,调查了四种不同的弹性成像模式:轴向应变弹性成像、剪切波弹性成像、连续剪切波弹性成像和3D弹性成像。轴向应变弹性图获得了中等水平的有效性和可靠性的证据。虽然横波速度的效度被分级为中等到高,但信度得到了非常低到中等的等级。连续横波弹性图的可靠性证据水平较低,效度证据水平极低。对三维横波弹性学进行分级的资料不足。关于测量误差的证据是不确定的,因此证据不能分级。结论:数量有限的研究探讨了跟腱病变的定量弹性成像,因为大多数证据是在健康人群中进行的。根据已确定的弹性成像测量特性的证据,没有一种不同类型的弹性成像在临床应用中表现出优越性。需要进一步采用纵向设计的高质量研究来调查反应性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Elastography in the assessment of the Achilles tendon: a systematic review of measurement properties.

Background: Managing and rehabilitating Achilles tendinopathy can be difficult, and the results are often unsatisfactory. Currently, clinicians use ultrasonography to diagnose the condition and predict symptom development. However, relying on subjective qualitative findings using ultrasound images alone, which are heavily influenced by the operator, may make it difficult to identify changes within the tendon. New technologies, such as elastography, offer opportunities to quantitatively investigate the mechanical and material properties of the tendon. This review aims to evaluate and synthesise the current literature on the measurement properties of elastography, which can be used to assess tendon pathologies.

Methods: A systematic review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. CINAHL, PubMed, Cochrane, Scopus, MEDLINE Complete, and Academic Search Ultimate were searched. Studies assessing the measurement properties concerning reliability, measurement error, validity, and responsiveness of the instruments identified in healthy and patients with Achilles tendinopathy were included. Two independent reviewers assessed the methodological quality using the Consensus-based Standards for the Selection of Health Measurement Instruments methodology.

Results: Out of the 1644 articles identified, 21 were included for the qualitative analysis investigating four different modalities of elastography: axial strain elastography, shear wave elastography, continuous shear wave elastography, and 3D elastography. Axial strain elastography obtained a moderate level of evidence for both validity and reliability. Although shear wave velocity was graded as moderate to high for validity, reliability obtained a very low to moderate grading. Continuous shear wave elastography was graded as having a low level of evidence for reliability and very low for validity. Insufficient data is available to grade three-dimensional shear wave elastography. Evidence on measurement error was indeterminate so evidence could not be graded.

Conclusions: A limited number of studies explored quantitative elastography on Achilles tendinopathy as most evidence was conducted on a healthy population. Based on the identified evidence on the measurement properties of elastography, none of the different types showed superiority for its use in clinical practice. Further high-quality studies with longitudinal design are needed to investigate responsiveness.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
10.30%
发文量
83
审稿时长
>12 weeks
期刊介绍: Journal of Foot and Ankle Research, the official journal of the Australian Podiatry Association and The College of Podiatry (UK), is an open access journal that encompasses all aspects of policy, organisation, delivery and clinical practice related to the assessment, diagnosis, prevention and management of foot and ankle disorders. Journal of Foot and Ankle Research covers a wide range of clinical subject areas, including diabetology, paediatrics, sports medicine, gerontology and geriatrics, foot surgery, physical therapy, dermatology, wound management, radiology, biomechanics and bioengineering, orthotics and prosthetics, as well the broad areas of epidemiology, policy, organisation and delivery of services related to foot and ankle care. The journal encourages submissions from all health professionals who manage lower limb conditions, including podiatrists, nurses, physical therapists and physiotherapists, orthopaedists, manual therapists, medical specialists and general medical practitioners, as well as health service researchers concerned with foot and ankle care. The Australian Podiatry Association and the College of Podiatry (UK) have reserve funds to cover the article-processing charge for manuscripts submitted by its members. Society members can email the appropriate contact at Australian Podiatry Association or The College of Podiatry to obtain the corresponding code to enter on submission.
期刊最新文献
Study of the impact of introducing a multimedia learning tool in podiatric medical courses. Exploring the psychosocial burden of foot complications in diabetes: A cross-sectional survey and qualitative interview study in a United Kingdom coastal community. Textured insoles may improve some gross motor balance measures but not endurance measures in children with motor coordination issues. A randomised controlled feasibility trial. Development of a research agenda for medical grade footwear in the Netherlands: A multidisciplinary multiphase project to determine the key research questions to advance scientific knowledge in the field. Peri-ankle muscles architecture and performance changes in patients with chronic ankle instability: A retrospective cross-sectional study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1