半球形凹窝对钛基台固位的影响。

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Advanced Prosthodontics Pub Date : 2023-04-01 DOI:10.4047/jap.2023.15.2.63
Jung-Hoon Choi, Seong-Joo Heo, Jai-Young Koak, Seong-Kyun Kim, Ji-Man Park, Jin-Soo Ahn
{"title":"半球形凹窝对钛基台固位的影响。","authors":"Jung-Hoon Choi,&nbsp;Seong-Joo Heo,&nbsp;Jai-Young Koak,&nbsp;Seong-Kyun Kim,&nbsp;Ji-Man Park,&nbsp;Jin-Soo Ahn","doi":"10.4047/jap.2023.15.2.63","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to assess the effect of hemispherical dimple structures on the retention of cobalt-chromium (Co-Cr) crowns cemented to titanium abutments, with different heights and numbers of dimples on the axial walls.</p><p><strong>Materials and methods: </strong>3.0-mm and 6.0-mm abutments (N = 180) and Co-Cr crowns were prepared. The experimental groups were divided into two and four dimple groups. The crowns were cemented by TempBond and PANAVIA F 2.0 cements. The retention forces were measured after thermal treatments. A two-way Analysis of Variance (ANOVA) and post-hoc Tukey HSD test were conducted to analyze change in retention forces by use of dimples between groups, as well as <i>t</i> test for the effect of abutment height change (α = .05).</p><p><strong>Results: </strong>Results of the two-way ANOVA showed a statistically significant difference in retention force due to the use of dimples, regardless of the types of cements used (<i>P</i> < .001). A significantly higher mean retention forces were observed in the groups with dimples than in the control group, using the post hoc Tukey HSD test (<i>P</i> < .001). Results of <i>t</i> test displayed a statistically significant increase in the retention force with 6.0-mm abutments compared with 3.0-mm abutments (<i>P</i> < .001). The groups without dimples revealed adhesive failure of cements, while the groups with dimples showed mixed failure of cements.</p><p><strong>Conclusion: </strong>Use of hemispherical dimples was effective for increasing retention forces of cemented crowns.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/f7/4d/jap-15-63.PMC10154144.pdf","citationCount":"0","resultStr":"{\"title\":\"Effect of hemispherical dimples at titanium implant abutments for the retention of cemented crowns.\",\"authors\":\"Jung-Hoon Choi,&nbsp;Seong-Joo Heo,&nbsp;Jai-Young Koak,&nbsp;Seong-Kyun Kim,&nbsp;Ji-Man Park,&nbsp;Jin-Soo Ahn\",\"doi\":\"10.4047/jap.2023.15.2.63\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study was to assess the effect of hemispherical dimple structures on the retention of cobalt-chromium (Co-Cr) crowns cemented to titanium abutments, with different heights and numbers of dimples on the axial walls.</p><p><strong>Materials and methods: </strong>3.0-mm and 6.0-mm abutments (N = 180) and Co-Cr crowns were prepared. The experimental groups were divided into two and four dimple groups. The crowns were cemented by TempBond and PANAVIA F 2.0 cements. The retention forces were measured after thermal treatments. A two-way Analysis of Variance (ANOVA) and post-hoc Tukey HSD test were conducted to analyze change in retention forces by use of dimples between groups, as well as <i>t</i> test for the effect of abutment height change (α = .05).</p><p><strong>Results: </strong>Results of the two-way ANOVA showed a statistically significant difference in retention force due to the use of dimples, regardless of the types of cements used (<i>P</i> < .001). A significantly higher mean retention forces were observed in the groups with dimples than in the control group, using the post hoc Tukey HSD test (<i>P</i> < .001). Results of <i>t</i> test displayed a statistically significant increase in the retention force with 6.0-mm abutments compared with 3.0-mm abutments (<i>P</i> < .001). The groups without dimples revealed adhesive failure of cements, while the groups with dimples showed mixed failure of cements.</p><p><strong>Conclusion: </strong>Use of hemispherical dimples was effective for increasing retention forces of cemented crowns.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/f7/4d/jap-15-63.PMC10154144.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2023.15.2.63\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2023.15.2.63","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究半球形凹窝结构对钴铬(Co-Cr)冠与钛基牙胶结后固位的影响。材料与方法:制备3.0 mm、6.0 mm基牙(N = 180)和Co-Cr冠。实验组分为二窝组和四窝组。冠用TempBond和PANAVIA f2.0粘结剂进行粘接。热处理后测定了固位力。采用双因素方差分析(ANOVA)和事后Tukey HSD检验分析两组间利用凹窝的固位力变化,采用t检验分析基台高度变化对固位力的影响(α = 0.05)。结果:双向方差分析结果显示,无论使用哪种类型的骨水泥,由于使用凹窝,固位力有统计学意义上的差异(P < 0.001)。采用事后Tukey HSD检验,有酒窝组的平均固位力明显高于对照组(P < 0.001)。t检验结果显示,与3.0 mm基牙相比,6.0 mm基牙的固位力明显增加(P < 0.001)。无窝窝组表现为骨水泥粘结失效,有窝窝组表现为骨水泥混合失效。结论:半球形凹窝可有效提高固位力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of hemispherical dimples at titanium implant abutments for the retention of cemented crowns.

Purpose: The aim of this study was to assess the effect of hemispherical dimple structures on the retention of cobalt-chromium (Co-Cr) crowns cemented to titanium abutments, with different heights and numbers of dimples on the axial walls.

Materials and methods: 3.0-mm and 6.0-mm abutments (N = 180) and Co-Cr crowns were prepared. The experimental groups were divided into two and four dimple groups. The crowns were cemented by TempBond and PANAVIA F 2.0 cements. The retention forces were measured after thermal treatments. A two-way Analysis of Variance (ANOVA) and post-hoc Tukey HSD test were conducted to analyze change in retention forces by use of dimples between groups, as well as t test for the effect of abutment height change (α = .05).

Results: Results of the two-way ANOVA showed a statistically significant difference in retention force due to the use of dimples, regardless of the types of cements used (P < .001). A significantly higher mean retention forces were observed in the groups with dimples than in the control group, using the post hoc Tukey HSD test (P < .001). Results of t test displayed a statistically significant increase in the retention force with 6.0-mm abutments compared with 3.0-mm abutments (P < .001). The groups without dimples revealed adhesive failure of cements, while the groups with dimples showed mixed failure of cements.

Conclusion: Use of hemispherical dimples was effective for increasing retention forces of cemented crowns.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
期刊最新文献
A novel brief questionnaire using a face rating scale to assess dental anxiety and fear. Clinical performance of implant-assisted removable partial dentures using implant surveyed crowns: a systematic review and meta-analysis. Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis. Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study. Recording maximal intercuspation and border positions of the mandible with intraoral scanner using the acquisition software's multi-occlusion function.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1