{"title":"与传统导向器相比,新型Zimmer Biomet根部瞄准导向器在胫骨隧道创建中的准确性","authors":"Takaaki Hiranaka , Takayuki Furumatsu , Yuki Okazaki , Keisuke Kintaka , Naohiro Higashihara , Masanori Tamura , Eiji Nakata , Toshifumi Ozaki","doi":"10.1016/j.asmart.2023.03.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Background/objective</h3><p>Accurate tibial tunnel creation is crucial for successful transtibial pullout repair of medial meniscus (MM) posterior root tears (MMPRTs). This study aimed to evaluate the accuracy of the newly developed Zimmer Biomet Root Aiming (ZeBRA) guide for transtibial pullout repair of MMPRTs.</p></div><div><h3>Methods</h3><p>This study included 50 patients who underwent transtibial pullout repair using the Unicorn Meniscal Root (UMR) (n = 25) and ZeBRA (n = 25) guides. The expected anatomic centre (AC) and tibial tunnel centre (TC) were assessed using three-dimensional postoperative computed tomography (CT) images. The expected AC was defined as the centre of the circle tangent to the triangular footprint of the MM posterior root. The expected AC and TC on the tibial surface were assessed using the percentage-based posterolateral location on the tibial surface. The absolute distance between the AC and TC (mm) was evaluated.</p></div><div><h3>Results</h3><p>The mean AC location was 76.1% ± 3.1% posterior and 40.8% ± 2.1% lateral, whereas the mean TC location was 76.7% ± 5.3% posterior and 37.2% ± 3.6% lateral using the UMR guide and 75.8% ± 3.1% posterior and 36.5% ± 2.4% lateral using the ZeBRA guide. No significant difference was observed in the absolute distance between the UMR and ZeBRA guides (3.9 ± 1.4 and 3.8 ± 1.3 mm, respectively; p = 0.617).</p></div><div><h3>Conclusions</h3><p>The newly developed ZeBRA guide allows accurate tibial tunnel creation, and its accuracy is comparable to that of the conventional UMR guide. Tibial tunnels were created at optimal positions using both guides, and the choice of the guide would depend on the surgeon's preference.</p></div>","PeriodicalId":44283,"journal":{"name":"Asia-Pacific Journal of Sport Medicine Arthroscopy Rehabilitation and Technology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10120359/pdf/main.pdf","citationCount":"0","resultStr":"{\"title\":\"Accuracy of the newly developed Zimmer Biomet Root Aiming guide in tibial tunnel creation compared with that of conventional guides\",\"authors\":\"Takaaki Hiranaka , Takayuki Furumatsu , Yuki Okazaki , Keisuke Kintaka , Naohiro Higashihara , Masanori Tamura , Eiji Nakata , Toshifumi Ozaki\",\"doi\":\"10.1016/j.asmart.2023.03.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background/objective</h3><p>Accurate tibial tunnel creation is crucial for successful transtibial pullout repair of medial meniscus (MM) posterior root tears (MMPRTs). This study aimed to evaluate the accuracy of the newly developed Zimmer Biomet Root Aiming (ZeBRA) guide for transtibial pullout repair of MMPRTs.</p></div><div><h3>Methods</h3><p>This study included 50 patients who underwent transtibial pullout repair using the Unicorn Meniscal Root (UMR) (n = 25) and ZeBRA (n = 25) guides. The expected anatomic centre (AC) and tibial tunnel centre (TC) were assessed using three-dimensional postoperative computed tomography (CT) images. The expected AC was defined as the centre of the circle tangent to the triangular footprint of the MM posterior root. The expected AC and TC on the tibial surface were assessed using the percentage-based posterolateral location on the tibial surface. The absolute distance between the AC and TC (mm) was evaluated.</p></div><div><h3>Results</h3><p>The mean AC location was 76.1% ± 3.1% posterior and 40.8% ± 2.1% lateral, whereas the mean TC location was 76.7% ± 5.3% posterior and 37.2% ± 3.6% lateral using the UMR guide and 75.8% ± 3.1% posterior and 36.5% ± 2.4% lateral using the ZeBRA guide. No significant difference was observed in the absolute distance between the UMR and ZeBRA guides (3.9 ± 1.4 and 3.8 ± 1.3 mm, respectively; p = 0.617).</p></div><div><h3>Conclusions</h3><p>The newly developed ZeBRA guide allows accurate tibial tunnel creation, and its accuracy is comparable to that of the conventional UMR guide. Tibial tunnels were created at optimal positions using both guides, and the choice of the guide would depend on the surgeon's preference.</p></div>\",\"PeriodicalId\":44283,\"journal\":{\"name\":\"Asia-Pacific Journal of Sport Medicine Arthroscopy Rehabilitation and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10120359/pdf/main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asia-Pacific Journal of Sport Medicine Arthroscopy Rehabilitation and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214687323000031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal of Sport Medicine Arthroscopy Rehabilitation and Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214687323000031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Accuracy of the newly developed Zimmer Biomet Root Aiming guide in tibial tunnel creation compared with that of conventional guides
Background/objective
Accurate tibial tunnel creation is crucial for successful transtibial pullout repair of medial meniscus (MM) posterior root tears (MMPRTs). This study aimed to evaluate the accuracy of the newly developed Zimmer Biomet Root Aiming (ZeBRA) guide for transtibial pullout repair of MMPRTs.
Methods
This study included 50 patients who underwent transtibial pullout repair using the Unicorn Meniscal Root (UMR) (n = 25) and ZeBRA (n = 25) guides. The expected anatomic centre (AC) and tibial tunnel centre (TC) were assessed using three-dimensional postoperative computed tomography (CT) images. The expected AC was defined as the centre of the circle tangent to the triangular footprint of the MM posterior root. The expected AC and TC on the tibial surface were assessed using the percentage-based posterolateral location on the tibial surface. The absolute distance between the AC and TC (mm) was evaluated.
Results
The mean AC location was 76.1% ± 3.1% posterior and 40.8% ± 2.1% lateral, whereas the mean TC location was 76.7% ± 5.3% posterior and 37.2% ± 3.6% lateral using the UMR guide and 75.8% ± 3.1% posterior and 36.5% ± 2.4% lateral using the ZeBRA guide. No significant difference was observed in the absolute distance between the UMR and ZeBRA guides (3.9 ± 1.4 and 3.8 ± 1.3 mm, respectively; p = 0.617).
Conclusions
The newly developed ZeBRA guide allows accurate tibial tunnel creation, and its accuracy is comparable to that of the conventional UMR guide. Tibial tunnels were created at optimal positions using both guides, and the choice of the guide would depend on the surgeon's preference.
期刊介绍:
The Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology (AP-SMART) is the official peer-reviewed, open access journal of the Asia-Pacific Knee, Arthroscopy and Sports Medicine Society (APKASS) and the Japanese Orthopaedic Society of Knee, Arthroscopy and Sports Medicine (JOSKAS). It is published quarterly, in January, April, July and October, by Elsevier. The mission of AP-SMART is to inspire clinicians, practitioners, scientists and engineers to work towards a common goal to improve quality of life in the international community. The Journal publishes original research, reviews, editorials, perspectives, and letters to the Editor. Multidisciplinary research with collaboration amongst clinicians and scientists from different disciplines will be the trend in the coming decades. AP-SMART provides a platform for the exchange of new clinical and scientific information in the most precise and expeditious way to achieve timely dissemination of information and cross-fertilization of ideas.