用无线可穿戴多普勒超声贴片检测总循环流量的变化:一项试点研究。

Chelsea E Munding, Jon-Émile S Kenny, Zhen Yang, Geoffrey Clarke, Mai Elfarnawany, Andrew M Eibl, Joseph K Eibl, Bhanu Nalla, Rony Atoui
{"title":"用无线可穿戴多普勒超声贴片检测总循环流量的变化:一项试点研究。","authors":"Chelsea E Munding,&nbsp;Jon-Émile S Kenny,&nbsp;Zhen Yang,&nbsp;Geoffrey Clarke,&nbsp;Mai Elfarnawany,&nbsp;Andrew M Eibl,&nbsp;Joseph K Eibl,&nbsp;Bhanu Nalla,&nbsp;Rony Atoui","doi":"10.1097/CCE.0000000000000914","DOIUrl":null,"url":null,"abstract":"<p><p>Measuring fluid responsiveness is important in the management of critically ill patients, with a 10-15% change in cardiac output typically being used to indicate \"fluid responsiveness.\" Ideally, these changes would be measured noninvasively and peripherally. The aim of this study was to determine how the common carotid artery (CCA) maximum velocity changes with total circulatory flow when confounding factors are mitigated and determine a value for CCA maximum velocity corresponding to a 10% change in total circulatory flow.</p><p><strong>Design: </strong>Prospective observational pilot study.</p><p><strong>Setting: </strong>Patients undergoing elective, on-pump coronary artery bypass grafting (CABG) surgery.</p><p><strong>Patients: </strong>Fourteen patients were referred for elective coronary artery bypass grafting surgery.</p><p><strong>Interventions: </strong>Cardiopulmonary bypass (CPB) pump flow changes during surgery, as chosen by the perfusionist.</p><p><strong>Measurements: </strong>A hands-free, wearable Doppler patch was used for CCA velocity measurements with the aim of preventing user errors in ultrasound measurements. Maximum CCA velocity was determined from the spectrogram acquired by the Doppler patch. CPB flow rates were recorded as displayed on the CPB console, and further measured from the peristaltic pulsation frequency visible on the recorded Doppler spectrograms.</p><p><strong>Main results: </strong>Changes in CCA maximum velocity tracked well with changes in CPB flow. On average, a 13.6% change in CCA maximum velocity was found to correspond to a 10% change in CPB flow rate.</p><p><strong>Conclusions: </strong>Changes in CCA velocity may be a useful surrogate for determining fluid responsiveness when user error can be mitigated.</p>","PeriodicalId":10759,"journal":{"name":"Critical Care Explorations","volume":"5 5","pages":"e0914"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6c/5f/cc9-5-e0914.PMC10166367.pdf","citationCount":"0","resultStr":"{\"title\":\"Detecting the Change in Total Circulatory Flow with a Wireless, Wearable Doppler Ultrasound Patch: A Pilot Study.\",\"authors\":\"Chelsea E Munding,&nbsp;Jon-Émile S Kenny,&nbsp;Zhen Yang,&nbsp;Geoffrey Clarke,&nbsp;Mai Elfarnawany,&nbsp;Andrew M Eibl,&nbsp;Joseph K Eibl,&nbsp;Bhanu Nalla,&nbsp;Rony Atoui\",\"doi\":\"10.1097/CCE.0000000000000914\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Measuring fluid responsiveness is important in the management of critically ill patients, with a 10-15% change in cardiac output typically being used to indicate \\\"fluid responsiveness.\\\" Ideally, these changes would be measured noninvasively and peripherally. The aim of this study was to determine how the common carotid artery (CCA) maximum velocity changes with total circulatory flow when confounding factors are mitigated and determine a value for CCA maximum velocity corresponding to a 10% change in total circulatory flow.</p><p><strong>Design: </strong>Prospective observational pilot study.</p><p><strong>Setting: </strong>Patients undergoing elective, on-pump coronary artery bypass grafting (CABG) surgery.</p><p><strong>Patients: </strong>Fourteen patients were referred for elective coronary artery bypass grafting surgery.</p><p><strong>Interventions: </strong>Cardiopulmonary bypass (CPB) pump flow changes during surgery, as chosen by the perfusionist.</p><p><strong>Measurements: </strong>A hands-free, wearable Doppler patch was used for CCA velocity measurements with the aim of preventing user errors in ultrasound measurements. Maximum CCA velocity was determined from the spectrogram acquired by the Doppler patch. CPB flow rates were recorded as displayed on the CPB console, and further measured from the peristaltic pulsation frequency visible on the recorded Doppler spectrograms.</p><p><strong>Main results: </strong>Changes in CCA maximum velocity tracked well with changes in CPB flow. On average, a 13.6% change in CCA maximum velocity was found to correspond to a 10% change in CPB flow rate.</p><p><strong>Conclusions: </strong>Changes in CCA velocity may be a useful surrogate for determining fluid responsiveness when user error can be mitigated.</p>\",\"PeriodicalId\":10759,\"journal\":{\"name\":\"Critical Care Explorations\",\"volume\":\"5 5\",\"pages\":\"e0914\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6c/5f/cc9-5-e0914.PMC10166367.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Critical Care Explorations\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/CCE.0000000000000914\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical Care Explorations","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/CCE.0000000000000914","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

测量液体反应性在危重病人的管理中很重要,通常使用10-15%的心输出量变化来指示“液体反应性”。理想情况下,这些变化应该是无创的和外围的。本研究的目的是确定当混杂因素减轻时,颈总动脉(CCA)最大流速如何随总循环流量变化,并确定总循环流量变化10%时对应的CCA最大流速值。设计:前瞻性观察性先导研究。背景:接受选择性无泵冠状动脉旁路移植术(CABG)的患者。患者:14例患者接受择期冠状动脉搭桥术。干预措施:手术期间体外循环(CPB)泵流量的变化,由灌注师选择。测量:使用免提、可穿戴的多普勒贴片进行CCA速度测量,目的是防止用户在超声测量中出现错误。最大CCA速度由多普勒贴片获得的频谱图确定。CPB流量记录显示在CPB控制台上,并进一步从记录的多普勒频谱图上可见的蠕动脉动频率进行测量。主要结果:CCA最大流速的变化与CPB流量的变化密切相关。平均而言,CCA最大流速的13.6%变化对应于CPB流量的10%变化。结论:当用户错误可以减轻时,CCA速度的变化可能是确定流体响应性的有用替代。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Detecting the Change in Total Circulatory Flow with a Wireless, Wearable Doppler Ultrasound Patch: A Pilot Study.

Measuring fluid responsiveness is important in the management of critically ill patients, with a 10-15% change in cardiac output typically being used to indicate "fluid responsiveness." Ideally, these changes would be measured noninvasively and peripherally. The aim of this study was to determine how the common carotid artery (CCA) maximum velocity changes with total circulatory flow when confounding factors are mitigated and determine a value for CCA maximum velocity corresponding to a 10% change in total circulatory flow.

Design: Prospective observational pilot study.

Setting: Patients undergoing elective, on-pump coronary artery bypass grafting (CABG) surgery.

Patients: Fourteen patients were referred for elective coronary artery bypass grafting surgery.

Interventions: Cardiopulmonary bypass (CPB) pump flow changes during surgery, as chosen by the perfusionist.

Measurements: A hands-free, wearable Doppler patch was used for CCA velocity measurements with the aim of preventing user errors in ultrasound measurements. Maximum CCA velocity was determined from the spectrogram acquired by the Doppler patch. CPB flow rates were recorded as displayed on the CPB console, and further measured from the peristaltic pulsation frequency visible on the recorded Doppler spectrograms.

Main results: Changes in CCA maximum velocity tracked well with changes in CPB flow. On average, a 13.6% change in CCA maximum velocity was found to correspond to a 10% change in CPB flow rate.

Conclusions: Changes in CCA velocity may be a useful surrogate for determining fluid responsiveness when user error can be mitigated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A New Dosing Frontier: Retrospective Assessment of Effluent Flow Rates and Residual Renal Function Among Critically Ill Patients Receiving Continuous Renal Replacement Therapy Hemodynamic Determinants of Cardiac Surgery-Associated Acute Kidney Injury Racial Differences in Accuracy of Predictive Models for High-Flow Nasal Cannula Failure in COVID-19 Knowledge and Practice Gaps in Pediatric Neurocritical Care Nursing: Lessons Learned From a Specialized Educational Boot Camp Unifying Fluid Responsiveness and Tolerance With Physiology: A Dynamic Interpretation of the Diamond–Forrester Classification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1