直接聚甲基丙烯酸甲酯基台和钛基氧化锆基台对种植体周围软组织整合的影响:小型猪研究。

IF 2.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Prosthodontics Pub Date : 2023-05-17 DOI:10.11607/ijp.7346
Miljana Bacevic, Frédéric Dethier, Geoffrey Lecloux, Laurence Seidel, Eric Rompen, France Lambert
{"title":"直接聚甲基丙烯酸甲酯基台和钛基氧化锆基台对种植体周围软组织整合的影响:小型猪研究。","authors":"Miljana Bacevic, Frédéric Dethier, Geoffrey Lecloux, Laurence Seidel, Eric Rompen, France Lambert","doi":"10.11607/ijp.7346","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess two types of abutment materials routinely used in daily prac-tice-direct polymethyl methacrylate (PMMA) and a zirconia-on-Ti-base abut-ment-and their effects on peri-implant soft tissues and bone remodeling in a mini-pig model.</p><p><strong>Materials and methods: </strong>A total of 40 implants were placed in five mini-pigs in a single-stage surgery. Four different types of abutment materials (n = 10 per group) were used: (1) titanium (control); (2) zirconia (control); (3) PMMA (test 1); and (4) Ti-base (zirconia bonded to a titanium framework; test 2). After 3 months of healing, the samples were collected and subjected to nondecalcified histology. The soft tissue dimensions (sulcus, junctional epithelium, and connective tissue attach-ment) were assessed on each abutment mesially and distally, and the distance from the implant margin to the first bone-to-implant contact (BIC) was measured.</p><p><strong>Results: </strong>No statistically significant differences were found among the four groups regarding soft tissue dimensions (P = .21), and a long junctional epithelium (mean: 4.1 mm) and a short connective tissue attachment (mean: 0.3 mm) were found in the majority of abutments. In some samples, the junctional epithelium extended all the way to the bone level. The measured peri-implant bone remodeling was similar in all four groups (P = .25).</p><p><strong>Conclusion: </strong>The present findings indicate that both di-rect PMMA and zirconia-on-Ti-base abutments seem to allow soft tissue integration similar to that of titanium and zirconia abutments. However, clinical studies are war-ranted to either confirm or refute the observed findings and to further investigate the influence of different materials on mucointegration.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2023-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effects of direct polymethylmethacrylate and zirconia-on-Ti-base abutments on peri-implant soft tissue integration: A study in minipigs.\",\"authors\":\"Miljana Bacevic, Frédéric Dethier, Geoffrey Lecloux, Laurence Seidel, Eric Rompen, France Lambert\",\"doi\":\"10.11607/ijp.7346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess two types of abutment materials routinely used in daily prac-tice-direct polymethyl methacrylate (PMMA) and a zirconia-on-Ti-base abut-ment-and their effects on peri-implant soft tissues and bone remodeling in a mini-pig model.</p><p><strong>Materials and methods: </strong>A total of 40 implants were placed in five mini-pigs in a single-stage surgery. Four different types of abutment materials (n = 10 per group) were used: (1) titanium (control); (2) zirconia (control); (3) PMMA (test 1); and (4) Ti-base (zirconia bonded to a titanium framework; test 2). After 3 months of healing, the samples were collected and subjected to nondecalcified histology. The soft tissue dimensions (sulcus, junctional epithelium, and connective tissue attach-ment) were assessed on each abutment mesially and distally, and the distance from the implant margin to the first bone-to-implant contact (BIC) was measured.</p><p><strong>Results: </strong>No statistically significant differences were found among the four groups regarding soft tissue dimensions (P = .21), and a long junctional epithelium (mean: 4.1 mm) and a short connective tissue attachment (mean: 0.3 mm) were found in the majority of abutments. In some samples, the junctional epithelium extended all the way to the bone level. The measured peri-implant bone remodeling was similar in all four groups (P = .25).</p><p><strong>Conclusion: </strong>The present findings indicate that both di-rect PMMA and zirconia-on-Ti-base abutments seem to allow soft tissue integration similar to that of titanium and zirconia abutments. However, clinical studies are war-ranted to either confirm or refute the observed findings and to further investigate the influence of different materials on mucointegration.</p>\",\"PeriodicalId\":50292,\"journal\":{\"name\":\"International Journal of Prosthodontics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.7346\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7346","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:在迷你猪模型中评估两种日常常规使用的基台材料--聚甲基丙烯酸甲酯基台(PMMA)和钛基氧化锆基台--及其对种植体周围软组织和骨重塑的影响:在单阶段手术中,在五只迷你猪身上共植入了 40 个种植体。使用了四种不同类型的基台材料(每组 10 个):(1)钛(对照组);(2)氧化锆(对照组);(3)PMMA(试验 1);(4)钛基(氧化锆与钛框架粘接;试验 2)。愈合 3 个月后,收集样本并进行非钙化组织学检查。对每个基台的中远端软组织尺寸(沟、连接上皮和结缔组织附着)进行评估,并测量从种植体边缘到第一个骨与种植体接触点(BIC)的距离:结果:四组基台的软组织尺寸差异无统计学意义(P = .21),大多数基台的交界上皮较长(平均:4.1 mm),结缔组织附着较短(平均:0.3 mm)。在一些样本中,交界上皮一直延伸到骨水平。所有四组的种植体周围骨重塑测量结果相似(P = .25):目前的研究结果表明,双直角 PMMA 基台和钛基氧化锆基台的软组织整合效果与钛基台和氧化锆基台相似。然而,临床研究需要证实或反驳观察到的结果,并进一步研究不同材料对粘液整合的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effects of direct polymethylmethacrylate and zirconia-on-Ti-base abutments on peri-implant soft tissue integration: A study in minipigs.

Purpose: To assess two types of abutment materials routinely used in daily prac-tice-direct polymethyl methacrylate (PMMA) and a zirconia-on-Ti-base abut-ment-and their effects on peri-implant soft tissues and bone remodeling in a mini-pig model.

Materials and methods: A total of 40 implants were placed in five mini-pigs in a single-stage surgery. Four different types of abutment materials (n = 10 per group) were used: (1) titanium (control); (2) zirconia (control); (3) PMMA (test 1); and (4) Ti-base (zirconia bonded to a titanium framework; test 2). After 3 months of healing, the samples were collected and subjected to nondecalcified histology. The soft tissue dimensions (sulcus, junctional epithelium, and connective tissue attach-ment) were assessed on each abutment mesially and distally, and the distance from the implant margin to the first bone-to-implant contact (BIC) was measured.

Results: No statistically significant differences were found among the four groups regarding soft tissue dimensions (P = .21), and a long junctional epithelium (mean: 4.1 mm) and a short connective tissue attachment (mean: 0.3 mm) were found in the majority of abutments. In some samples, the junctional epithelium extended all the way to the bone level. The measured peri-implant bone remodeling was similar in all four groups (P = .25).

Conclusion: The present findings indicate that both di-rect PMMA and zirconia-on-Ti-base abutments seem to allow soft tissue integration similar to that of titanium and zirconia abutments. However, clinical studies are war-ranted to either confirm or refute the observed findings and to further investigate the influence of different materials on mucointegration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Prosthodontics
International Journal of Prosthodontics 医学-牙科与口腔外科
CiteScore
3.20
自引率
4.30%
发文量
82
审稿时长
6-12 weeks
期刊介绍: Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP) Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.
期刊最新文献
A Comparison of Abutment Screw Loosening in 24-Degree Angulation-Correcting and Straight Implants: An In Vitro Study. Analysis of Topography, Flexural Strength, and Microstructure of a Lithium Disilicate Glass- Ceramic after Surface Finishing. Aging and Fracture Resistance of Screw-Retained Implant-Supported Molar Crowns Fabricated from Lithium Disilicate Containing Virgilite. Comparison Between Interocclusal Registration Using Silicone Bite Registration Material and Intraoral Scanner on Clenching Strength. Satisfaction with Labial Reinforcement of Custom-Made Mouthguards Among a Cohort of Rugby Union Players: A Randomized Crossover Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1