主动脉根部置换术中卷曲涤纶血管的体外建模。

IF 1.3 American journal of cardiovascular disease Pub Date : 2023-01-01
Rakan I Nazer, Abdulaziz Alhothali, Ali Albarrati
{"title":"主动脉根部置换术中卷曲涤纶血管的体外建模。","authors":"Rakan I Nazer,&nbsp;Abdulaziz Alhothali,&nbsp;Ali Albarrati","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To objectively quantify the effect of flattening the crimps in Dacron tube grafts on the radial compliance under pulsatile pressure. We aimed to minimize the dimensional changes in woven Dacron graft tubes by applying axial stretch to the graft. We hypothesize this might reduce the risk of coronary button misalignment in aortic root replacement.</p><p><strong>Methods: </strong>In an in vitro pulsatile model that delivered systemic circulatory pressures to Dacron tube grafts, we measured oscillatory movements in 26-30 mm Dacron vascular tube grafts before and after flattening the graft crimps. We also describe our surgical methods and clinical experiences in replacing the aortic root.</p><p><strong>Results: </strong>Flattening the crimps in Dacron tubes with axial stretching significantly reduced the mean maximal oscillation distance measured radially during each balloon pulse (3.2 ± 0.8 mm, 95% CI: 2.6, 3.7 mm vs. 1.5 ± 0.5 mm, 95% CI: 1.2, 1.7 mm; P < 0.001).</p><p><strong>Conclusion: </strong>The radial compliance of woven Dacron tubes was significantly reduced after flattening the crimps. Applying axial stretch to the Dacron grafts prior to determining the coronary button attachment site can help maintain dimensional stability in the graft, which may reduce the risk of coronary malperfusion in aortic root replacment.</p>","PeriodicalId":7427,"journal":{"name":"American journal of cardiovascular disease","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10193250/pdf/ajcd0013-0059.pdf","citationCount":"0","resultStr":"{\"title\":\"In vitro modeling of crimped Dacron vascular grafts for aortic root replacement.\",\"authors\":\"Rakan I Nazer,&nbsp;Abdulaziz Alhothali,&nbsp;Ali Albarrati\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To objectively quantify the effect of flattening the crimps in Dacron tube grafts on the radial compliance under pulsatile pressure. We aimed to minimize the dimensional changes in woven Dacron graft tubes by applying axial stretch to the graft. We hypothesize this might reduce the risk of coronary button misalignment in aortic root replacement.</p><p><strong>Methods: </strong>In an in vitro pulsatile model that delivered systemic circulatory pressures to Dacron tube grafts, we measured oscillatory movements in 26-30 mm Dacron vascular tube grafts before and after flattening the graft crimps. We also describe our surgical methods and clinical experiences in replacing the aortic root.</p><p><strong>Results: </strong>Flattening the crimps in Dacron tubes with axial stretching significantly reduced the mean maximal oscillation distance measured radially during each balloon pulse (3.2 ± 0.8 mm, 95% CI: 2.6, 3.7 mm vs. 1.5 ± 0.5 mm, 95% CI: 1.2, 1.7 mm; P < 0.001).</p><p><strong>Conclusion: </strong>The radial compliance of woven Dacron tubes was significantly reduced after flattening the crimps. Applying axial stretch to the Dacron grafts prior to determining the coronary button attachment site can help maintain dimensional stability in the graft, which may reduce the risk of coronary malperfusion in aortic root replacment.</p>\",\"PeriodicalId\":7427,\"journal\":{\"name\":\"American journal of cardiovascular disease\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10193250/pdf/ajcd0013-0059.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of cardiovascular disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of cardiovascular disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:客观量化压平涤纶管对搏动压力下桡骨顺应性的影响。我们的目标是通过向接枝施加轴向拉伸来最小化编织涤纶接枝管的尺寸变化。我们假设这可能会降低主动脉根置换术中冠状动脉钮扣错位的风险。方法:建立体外脉动模型,给涤纶管移植物施加体循环压力,测量26-30 mm涤纶管移植物卷曲压平前后的振荡运动。同时我们也介绍了主动脉根部置换的手术方法和临床经验。结果:轴向拉伸使涤纶管卷曲变平可显著减少每次球囊脉冲径向测量的平均最大振荡距离(3.2±0.8 mm, 95% CI: 2.6, 3.7 mm vs. 1.5±0.5 mm, 95% CI: 1.2, 1.7 mm;P < 0.001)。结论:压平卷曲后织物涤纶管的径向顺应性明显降低。在确定冠状动脉钮扣附着位置之前,对涤纶移植物进行轴向拉伸,有助于维持移植物的尺寸稳定性,从而降低主动脉根置换术中冠状动脉灌注不良的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In vitro modeling of crimped Dacron vascular grafts for aortic root replacement.

Objective: To objectively quantify the effect of flattening the crimps in Dacron tube grafts on the radial compliance under pulsatile pressure. We aimed to minimize the dimensional changes in woven Dacron graft tubes by applying axial stretch to the graft. We hypothesize this might reduce the risk of coronary button misalignment in aortic root replacement.

Methods: In an in vitro pulsatile model that delivered systemic circulatory pressures to Dacron tube grafts, we measured oscillatory movements in 26-30 mm Dacron vascular tube grafts before and after flattening the graft crimps. We also describe our surgical methods and clinical experiences in replacing the aortic root.

Results: Flattening the crimps in Dacron tubes with axial stretching significantly reduced the mean maximal oscillation distance measured radially during each balloon pulse (3.2 ± 0.8 mm, 95% CI: 2.6, 3.7 mm vs. 1.5 ± 0.5 mm, 95% CI: 1.2, 1.7 mm; P < 0.001).

Conclusion: The radial compliance of woven Dacron tubes was significantly reduced after flattening the crimps. Applying axial stretch to the Dacron grafts prior to determining the coronary button attachment site can help maintain dimensional stability in the graft, which may reduce the risk of coronary malperfusion in aortic root replacment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
American journal of cardiovascular disease
American journal of cardiovascular disease CARDIAC & CARDIOVASCULAR SYSTEMS-
自引率
0.00%
发文量
21
期刊最新文献
Disparities by sex, race, and region in acute myocardial infarction-related outcomes during the early COVID-19 pandemic: the national inpatient sample analysis. Evaluating antiarrhythmic drugs for managing infants with supraventricular tachycardia; a review. Gender-based disparities in outcomes of coronary bifurcation stenting in patients undergoing percutaneous coronary intervention: a systematic review and meta-analysis. Impact of frailty index on cardiovascular outcomes and readmissions of patent foramen ovale closure procedure: a propensity matched national analysis. Percutaneous coronary intervention involving coronary bifurcation is associated with higher mortality and complications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1