使用三维有限元分析评估骨模型上90°和45°角下微型植入物的应变和插入扭矩。

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Contemporary Clinical Dentistry Pub Date : 2023-01-01 Epub Date: 2022-11-28 DOI:10.4103/ccd.ccd_725_21
Jes Xavier, K Sarika, V V Ajith, N K Sapna Varma
{"title":"使用三维有限元分析评估骨模型上90°和45°角下微型植入物的应变和插入扭矩。","authors":"Jes Xavier,&nbsp;K Sarika,&nbsp;V V Ajith,&nbsp;N K Sapna Varma","doi":"10.4103/ccd.ccd_725_21","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Temporary anchorage devices or mini-implants have gained great attraction due to its capability to provide absolute anchorage, low cost, versatility, and can be loaded immediately after placement.</p><p><strong>Aims and objectives: </strong>The aim of this study is to use FEA analysis to assess the strain and insertion torque of mini-implants on a bone model at two distinct angulations of 45° and 90°.</p><p><strong>Materials and methods: </strong>A computer-aided three-dimensional (3-D) model representing alveolar bone and mini-implants were developed using ANSYS software. Computed tomography scan images of the implant and the alveolar bone were taken and exported in DICOM format for 3-D image processing. The thickness of the bone model is 1 mm. Ti6Al4V orthodontic single and double threaded mini-implants (L = 7 mm, D = 1.5 mm) were inclined at 45° and 90° on to the bone surface to measure the insertion torque and strain produced.</p><p><strong>Results: </strong>Maximum insertion torque (MIT) for single-threaded mini implant at 45° and 90° angulations are 20.001 Nmm and 19.977 Nmm, respectively. MIT for double-threaded mini-implants obtained is 19.977 Nmm at 90° and 19.991 Nmm at 45° angulation. The strain of the bone at 90° angulation for single-threaded mini-implant is 0.00893 mm and for single-threaded mini implant at 45° angulation is 0.01257 mm. The strain in double-threaded mini-implant at 90° angulation is 0.0125 mm and that of 45° angulation is 0.01773 mm.</p><p><strong>Conclusion: </strong>For maximum stability single-threaded mini-implant with perpendicular insertion, angle is preferred.</p>","PeriodicalId":10632,"journal":{"name":"Contemporary Clinical Dentistry","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c2/62/CCD-14-25.PMC10209767.pdf","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Strain and Insertion Torque of Mini-implants at 90° and 45° Angulations on a Bone Model using Three-Dimensional Finite Element Analysis.\",\"authors\":\"Jes Xavier,&nbsp;K Sarika,&nbsp;V V Ajith,&nbsp;N K Sapna Varma\",\"doi\":\"10.4103/ccd.ccd_725_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Temporary anchorage devices or mini-implants have gained great attraction due to its capability to provide absolute anchorage, low cost, versatility, and can be loaded immediately after placement.</p><p><strong>Aims and objectives: </strong>The aim of this study is to use FEA analysis to assess the strain and insertion torque of mini-implants on a bone model at two distinct angulations of 45° and 90°.</p><p><strong>Materials and methods: </strong>A computer-aided three-dimensional (3-D) model representing alveolar bone and mini-implants were developed using ANSYS software. Computed tomography scan images of the implant and the alveolar bone were taken and exported in DICOM format for 3-D image processing. The thickness of the bone model is 1 mm. Ti6Al4V orthodontic single and double threaded mini-implants (L = 7 mm, D = 1.5 mm) were inclined at 45° and 90° on to the bone surface to measure the insertion torque and strain produced.</p><p><strong>Results: </strong>Maximum insertion torque (MIT) for single-threaded mini implant at 45° and 90° angulations are 20.001 Nmm and 19.977 Nmm, respectively. MIT for double-threaded mini-implants obtained is 19.977 Nmm at 90° and 19.991 Nmm at 45° angulation. The strain of the bone at 90° angulation for single-threaded mini-implant is 0.00893 mm and for single-threaded mini implant at 45° angulation is 0.01257 mm. The strain in double-threaded mini-implant at 90° angulation is 0.0125 mm and that of 45° angulation is 0.01773 mm.</p><p><strong>Conclusion: </strong>For maximum stability single-threaded mini-implant with perpendicular insertion, angle is preferred.</p>\",\"PeriodicalId\":10632,\"journal\":{\"name\":\"Contemporary Clinical Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c2/62/CCD-14-25.PMC10209767.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contemporary Clinical Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ccd.ccd_725_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/11/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contemporary Clinical Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ccd.ccd_725_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/11/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:临时锚固装置或微型植入物由于其提供绝对锚固的能力、低成本、多功能性以及放置后可立即加载而获得了极大的吸引力。目的和目的:本研究的目的是使用有限元分析来评估骨模型上微型植入物在45°和90°两个不同角度下的应变和插入扭矩。材料和方法:使用ANSYS软件开发了一个代表牙槽骨和微型植入物的计算机辅助三维模型。植入物和牙槽骨的计算机断层扫描图像被采集并以DICOM格式导出,用于3D图像处理。骨模型的厚度为1 mm。将Ti6Al4V正畸单螺纹和双螺纹微型植入物(L=7 mm,D=1.5 mm)在骨表面倾斜45°和90°,以测量产生的插入扭矩和应变。结果:45°和90°角度的单螺纹微型植入物的最大插入扭矩(MIT)分别为20.001Nmm和19.977Nmm。获得的双螺纹迷你植入物的MIT在90°时为19.977 Nmm,在45°角时为19.991 Nmm。单螺纹微型植入物在90°角时的骨骼应变为0.00893 mm,单螺纹微型种植物在45°角时为0.01257 mm。双螺纹微型种植体在90°角度时的应变为0.0125 mm,45°角度时为0.01773 mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Strain and Insertion Torque of Mini-implants at 90° and 45° Angulations on a Bone Model using Three-Dimensional Finite Element Analysis.

Background: Temporary anchorage devices or mini-implants have gained great attraction due to its capability to provide absolute anchorage, low cost, versatility, and can be loaded immediately after placement.

Aims and objectives: The aim of this study is to use FEA analysis to assess the strain and insertion torque of mini-implants on a bone model at two distinct angulations of 45° and 90°.

Materials and methods: A computer-aided three-dimensional (3-D) model representing alveolar bone and mini-implants were developed using ANSYS software. Computed tomography scan images of the implant and the alveolar bone were taken and exported in DICOM format for 3-D image processing. The thickness of the bone model is 1 mm. Ti6Al4V orthodontic single and double threaded mini-implants (L = 7 mm, D = 1.5 mm) were inclined at 45° and 90° on to the bone surface to measure the insertion torque and strain produced.

Results: Maximum insertion torque (MIT) for single-threaded mini implant at 45° and 90° angulations are 20.001 Nmm and 19.977 Nmm, respectively. MIT for double-threaded mini-implants obtained is 19.977 Nmm at 90° and 19.991 Nmm at 45° angulation. The strain of the bone at 90° angulation for single-threaded mini-implant is 0.00893 mm and for single-threaded mini implant at 45° angulation is 0.01257 mm. The strain in double-threaded mini-implant at 90° angulation is 0.0125 mm and that of 45° angulation is 0.01773 mm.

Conclusion: For maximum stability single-threaded mini-implant with perpendicular insertion, angle is preferred.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Contemporary Clinical Dentistry
Contemporary Clinical Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.50
自引率
0.00%
发文量
52
审稿时长
23 weeks
期刊介绍: The journal Contemporary Clinical Dentistry (CCD) (Print ISSN: 0976-237X, E-ISSN:0976- 2361) is peer-reviewed journal published on behalf of Maharishi Markandeshwar University and issues are published quarterly in the last week of March, June, September and December. The Journal publishes Original research papers, clinical studies, case series strictly of clinical interest. Manuscripts are invited from all specialties of Dentistry i.e. Conservative dentistry and Endodontics, Dentofacial orthopedics and Orthodontics, Oral medicine and Radiology, Oral pathology, Oral surgery, Orodental diseases, Pediatric Dentistry, Periodontics, Clinical aspects of Public Health dentistry and Prosthodontics. Review articles are not accepted. Review, if published, will only be by invitation from eminent scholars and academicians of National and International repute in the field of Medical/Dental education.
期刊最新文献
In vitro Molecular Mechanisms of Anticancer Activity of Stevioside in Human Osteosarcoma Cell Lines (Sarcoma Osteogenic). A Comprehensive Approach to Unilateral Cleft Lip and Palate Management through Presurgical Nasoalveolar Molding and Surgical Repair in a Neonate. A Single-Step Root Coverage Procedure Using Modified Bridge Flap Technique and De-epithelialized Gingival Unit Graft: A Prospective Clinical Study. Atypical Presentation and Surgical Management of Ectopic Mandibular Third Molar in Subcondylar Region: A Rare Case Report. Benign Fibrous Histiocytoma of Gingiva: A Rare Case Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1