Brittany D Bulbrook, Jaclyn N Chopp-Hurley, Emily G Wiebenga, Janet M Pritchard, Anthony A Gatti, Peter J Keir, Monica R Maly
{"title":"在新型超声波传感器附件的帮助下,以最佳长度测量股直肌和腹外肌的肌肉结构和皮下脂肪。","authors":"Brittany D Bulbrook, Jaclyn N Chopp-Hurley, Emily G Wiebenga, Janet M Pritchard, Anthony A Gatti, Peter J Keir, Monica R Maly","doi":"10.3138/ptc-2021-0016","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Purpose:</i></b> This cross-sectional study determines the sensitivity of muscle architecture and fat measurements of the rectus femoris (RF) and vastus lateralis (VL) muscles from ultrasound images acquired with varying transducer tilt, using a novel transducer attachment, in healthy adults. Secondary objectives were to estimate intrarater and interrater reliability of image measurement and acquisition, respectively. <b><i>Methods:</i></b> Thirty healthy adults participated (15 women and 15 men; 25 [SD 2.5] y). Ultrasound image acquisition was conducted by two raters at different transducer tilts relative to the skin: estimated perpendicular, and five measured angles (80°, 85°, 90°, 95°, 100°) using the transducer attachment. Muscle thickness (MT), subcutaneous fat thickness (FT), pennation angle (PA), and fascicle length (FL) were measured. Sensitivity and reliability were assessed using intra-class correlation coefficients (ICCs) and standard error of measurements (SEMs). <b><i>Results:</i></b> MT and FT for RF and VL were not sensitive to transducer tilt. However, PA and FL were sensitive to transducer tilt. MT and FT for both muscles showed high ICCs and low SEMs for intrarater and interrater reliability. For PA of both muscles, standardizing transducer tilt improved interrater ICCs and lowered SEMs. <b><i>Conclusion:</i></b> MT and FT measurements of RF and VL acquired at 60° knee flexion are robust to varying transducer tilt angles. PA measurements benefit from standardizing transducer tilt.</p>","PeriodicalId":54606,"journal":{"name":"Physiotherapy Canada","volume":"75 1","pages":"74-82"},"PeriodicalIF":0.9000,"publicationDate":"2023-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10211386/pdf/","citationCount":"0","resultStr":"{\"title\":\"Muscle Architecture and Subcutaneous Fat Measurements of Rectus Femoris and Vastus Lateralis at Optimal Length Aided by a Novel Ultrasound Transducer Attachment.\",\"authors\":\"Brittany D Bulbrook, Jaclyn N Chopp-Hurley, Emily G Wiebenga, Janet M Pritchard, Anthony A Gatti, Peter J Keir, Monica R Maly\",\"doi\":\"10.3138/ptc-2021-0016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Purpose:</i></b> This cross-sectional study determines the sensitivity of muscle architecture and fat measurements of the rectus femoris (RF) and vastus lateralis (VL) muscles from ultrasound images acquired with varying transducer tilt, using a novel transducer attachment, in healthy adults. Secondary objectives were to estimate intrarater and interrater reliability of image measurement and acquisition, respectively. <b><i>Methods:</i></b> Thirty healthy adults participated (15 women and 15 men; 25 [SD 2.5] y). Ultrasound image acquisition was conducted by two raters at different transducer tilts relative to the skin: estimated perpendicular, and five measured angles (80°, 85°, 90°, 95°, 100°) using the transducer attachment. Muscle thickness (MT), subcutaneous fat thickness (FT), pennation angle (PA), and fascicle length (FL) were measured. Sensitivity and reliability were assessed using intra-class correlation coefficients (ICCs) and standard error of measurements (SEMs). <b><i>Results:</i></b> MT and FT for RF and VL were not sensitive to transducer tilt. However, PA and FL were sensitive to transducer tilt. MT and FT for both muscles showed high ICCs and low SEMs for intrarater and interrater reliability. For PA of both muscles, standardizing transducer tilt improved interrater ICCs and lowered SEMs. <b><i>Conclusion:</i></b> MT and FT measurements of RF and VL acquired at 60° knee flexion are robust to varying transducer tilt angles. PA measurements benefit from standardizing transducer tilt.</p>\",\"PeriodicalId\":54606,\"journal\":{\"name\":\"Physiotherapy Canada\",\"volume\":\"75 1\",\"pages\":\"74-82\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-02-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10211386/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physiotherapy Canada\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3138/ptc-2021-0016\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiotherapy Canada","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3138/ptc-2021-0016","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0
摘要
目的:这项横断面研究确定了使用新型换能器附件从不同换能器倾斜度下采集的超声图像中测量健康成人股直肌(RF)和股外侧肌(VL)肌肉结构和脂肪的灵敏度。次要目标是分别评估图像测量和采集的内部和内部可靠性。方法:30 名健康成年人(15 名女性和 15 名男性;25 [SD 2.5] 岁)参加了此次研究。超声图像采集由两名评定者在不同的换能器相对于皮肤的倾斜角度下进行:估计垂直角度和使用换能器附件测量的五个角度(80°、85°、90°、95°、100°)。肌肉厚度 (MT)、皮下脂肪厚度 (FT)、垂线角度 (PA) 和筋膜长度 (FL) 均已测量。使用类内相关系数(ICC)和测量标准误差(SEM)评估灵敏度和可靠性。结果RF和VL的MT和FT对换能器倾斜不敏感。但 PA 和 FL 对传感器倾斜敏感。两块肌肉的 MT 和 FT 显示出较高的 ICC 和较低的 SEM。就两块肌肉的 PA 而言,将换能器倾斜标准化可提高评分者之间的 ICCs,降低 SEMs。结论在膝关节屈曲60°时采集的RF和VL的MT和FT测量结果对不同的换能器倾斜角度有很好的适应性。PA测量可从标准化的传感器倾斜角度中获益。
Muscle Architecture and Subcutaneous Fat Measurements of Rectus Femoris and Vastus Lateralis at Optimal Length Aided by a Novel Ultrasound Transducer Attachment.
Purpose: This cross-sectional study determines the sensitivity of muscle architecture and fat measurements of the rectus femoris (RF) and vastus lateralis (VL) muscles from ultrasound images acquired with varying transducer tilt, using a novel transducer attachment, in healthy adults. Secondary objectives were to estimate intrarater and interrater reliability of image measurement and acquisition, respectively. Methods: Thirty healthy adults participated (15 women and 15 men; 25 [SD 2.5] y). Ultrasound image acquisition was conducted by two raters at different transducer tilts relative to the skin: estimated perpendicular, and five measured angles (80°, 85°, 90°, 95°, 100°) using the transducer attachment. Muscle thickness (MT), subcutaneous fat thickness (FT), pennation angle (PA), and fascicle length (FL) were measured. Sensitivity and reliability were assessed using intra-class correlation coefficients (ICCs) and standard error of measurements (SEMs). Results: MT and FT for RF and VL were not sensitive to transducer tilt. However, PA and FL were sensitive to transducer tilt. MT and FT for both muscles showed high ICCs and low SEMs for intrarater and interrater reliability. For PA of both muscles, standardizing transducer tilt improved interrater ICCs and lowered SEMs. Conclusion: MT and FT measurements of RF and VL acquired at 60° knee flexion are robust to varying transducer tilt angles. PA measurements benefit from standardizing transducer tilt.
期刊介绍:
Physiotherapy Canada is the official, scholarly, refereed journal of the Canadian Physiotherapy Association (CPA), giving direction to excellence in clinical science and reasoning, knowledge translation, therapeutic skills and patient-centred care.
Founded in 1923, Physiotherapy Canada meets the diverse needs of national and international readers and serves as a key repository of inquiries, evidence and advances in the practice of physiotherapy.
Physiotherapy Canada publishes the results of qualitative and quantitative research including systematic reviews, meta analyses, meta syntheses, public/health policy research, clinical practice guidelines, and case reports. Key messages, clinical commentaries, brief reports and book reviews support knowledge translation to clinical practice.
In addition to delivering authoritative, original scientific articles and reports of significant clinical studies, Physiotherapy Canada’s editorials and abstracts are presented in both English and French, expanding the journal’s reach nationally and internationally. Key messages form an integral part of each research article, providing a succinct summary for readers of all levels. This approach also allows readers to quickly get a feel for ‘what is already known’ and ‘what this study adds to’ the subject.
Clinician’s commentaries for key articles assist in bridging research and practice by discussing the article’s impact at the clinical level. The journal also features special themed series which bring readers up to date research supporting evidence-informed practice.
The Canadian Physiotherapy Association (CPA) is the national professional association representing almost 15,000 members distributed throughout all provinces and territories. CPA’s mission is to provide leadership and direction to the physiotherapy profession, foster excellence in practice, education and research, and promote high standards of health in Canada.