传统试管法与红细胞磁化法测定红细胞同种异体抗体的比较。

Xue-Hua He, Hong Yan, Chun-Yan Wang, Xue-Yun Duan, Jia-Jia Qiao, Xiao-Jun Guo, Hong-Bin Zhao, Dong Ren, Jian-She Li, Qiang Zhang
{"title":"传统试管法与红细胞磁化法测定红细胞同种异体抗体的比较。","authors":"Xue-Hua He,&nbsp;Hong Yan,&nbsp;Chun-Yan Wang,&nbsp;Xue-Yun Duan,&nbsp;Jia-Jia Qiao,&nbsp;Xiao-Jun Guo,&nbsp;Hong-Bin Zhao,&nbsp;Dong Ren,&nbsp;Jian-She Li,&nbsp;Qiang Zhang","doi":"10.4331/wjbc.v14.i3.62","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Erythrocyte alloantibodies are mainly produced after immune stimulation, such as blood transfusion, pregnancy, and transplantation, and are the leading causes of severe hemolytic transfusion reactions and difficulty in blood grouping and matching. Therefore, antibody screening is critical to prevent and improve red cell alloantibodies. Routine tube assay is the primary detection method of antibody screening. Recently, erythrocyte-magnetized technology (EMT) has been increasingly used in clinical practice. This study intends to probe the application and efficacy of the conventional tube and EMT in red blood cell alloantibody titration to provide a reference for clinical blood transfusion.</p><p><strong>Aim: </strong>To investigate the application value of conventional tube and EMT in red blood cell alloantibody titration and enhance the safety of blood transfusion practice.</p><p><strong>Methods: </strong>A total of 1298 blood samples were harvested from blood donors at the Department of Blood Transfusion of our hospital from March 2021 to December 2022. A 5 mL blood sample was collected in tubing, which was then cut, and the whole blood was put into a test tube for centrifugation to separate the serum. Different red blood cell blood group antibody titers were simultaneously detected using the tube polybrene test, tube antiglobulin test (AGT), and EMT screening irregular antibody methods to determine the best test method.</p><p><strong>Results: </strong>Simultaneous detection was performed through the tube polybrene test, tube AGT and EMT screening irregular antibodies. It was discovered that the EMT screening irregular antibody method could detect all immunoglobulin G (IgG) and immunoglobulin M (IgM) irregular antibodies, and the results of manual tube AGT were satisfactory, but the operation time was lengthy, and the equipment had a large footprint. The EMT screening irregular antibody assay was also conducted to determine its activity against type O Rh (D) red blood cells, and the outcomes were satisfactory. Furthermore, compared to the conventional tube method, the EMT screening irregular antibody method was more cost-effective and had significantly higher detection efficiency.</p><p><strong>Conclusion: </strong>With a higher detection rate, the EMT screening irregular antibody method can detect both IgG and IgM irregular antibodies faster and more effectively than the conventional tube method.</p>","PeriodicalId":23691,"journal":{"name":"World journal of biological chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/e2/8d/WJBC-14-62.PMC10236968.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparison of the conventional tube and erythrocyte-magnetized technology in titration of red blood cell alloantibodies.\",\"authors\":\"Xue-Hua He,&nbsp;Hong Yan,&nbsp;Chun-Yan Wang,&nbsp;Xue-Yun Duan,&nbsp;Jia-Jia Qiao,&nbsp;Xiao-Jun Guo,&nbsp;Hong-Bin Zhao,&nbsp;Dong Ren,&nbsp;Jian-She Li,&nbsp;Qiang Zhang\",\"doi\":\"10.4331/wjbc.v14.i3.62\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Erythrocyte alloantibodies are mainly produced after immune stimulation, such as blood transfusion, pregnancy, and transplantation, and are the leading causes of severe hemolytic transfusion reactions and difficulty in blood grouping and matching. Therefore, antibody screening is critical to prevent and improve red cell alloantibodies. Routine tube assay is the primary detection method of antibody screening. Recently, erythrocyte-magnetized technology (EMT) has been increasingly used in clinical practice. This study intends to probe the application and efficacy of the conventional tube and EMT in red blood cell alloantibody titration to provide a reference for clinical blood transfusion.</p><p><strong>Aim: </strong>To investigate the application value of conventional tube and EMT in red blood cell alloantibody titration and enhance the safety of blood transfusion practice.</p><p><strong>Methods: </strong>A total of 1298 blood samples were harvested from blood donors at the Department of Blood Transfusion of our hospital from March 2021 to December 2022. A 5 mL blood sample was collected in tubing, which was then cut, and the whole blood was put into a test tube for centrifugation to separate the serum. Different red blood cell blood group antibody titers were simultaneously detected using the tube polybrene test, tube antiglobulin test (AGT), and EMT screening irregular antibody methods to determine the best test method.</p><p><strong>Results: </strong>Simultaneous detection was performed through the tube polybrene test, tube AGT and EMT screening irregular antibodies. It was discovered that the EMT screening irregular antibody method could detect all immunoglobulin G (IgG) and immunoglobulin M (IgM) irregular antibodies, and the results of manual tube AGT were satisfactory, but the operation time was lengthy, and the equipment had a large footprint. The EMT screening irregular antibody assay was also conducted to determine its activity against type O Rh (D) red blood cells, and the outcomes were satisfactory. Furthermore, compared to the conventional tube method, the EMT screening irregular antibody method was more cost-effective and had significantly higher detection efficiency.</p><p><strong>Conclusion: </strong>With a higher detection rate, the EMT screening irregular antibody method can detect both IgG and IgM irregular antibodies faster and more effectively than the conventional tube method.</p>\",\"PeriodicalId\":23691,\"journal\":{\"name\":\"World journal of biological chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/e2/8d/WJBC-14-62.PMC10236968.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World journal of biological chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4331/wjbc.v14.i3.62\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World journal of biological chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4331/wjbc.v14.i3.62","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:红细胞同种异体抗体主要在输血、妊娠、移植等免疫刺激后产生,是严重溶血性输血反应和血型配型困难的主要原因。因此,抗体筛选对于预防和改善红细胞同种异体抗体至关重要。常规试管试验是抗体筛选的主要检测方法。近年来,红细胞磁化技术(EMT)越来越多地应用于临床。本研究旨在探讨常规试管和EMT在红细胞异体抗体滴定中的应用及疗效,为临床输血提供参考。目的:探讨常规试管和EMT在红细胞异体抗体滴定中的应用价值,提高输血实践的安全性。方法:于2021年3月至2022年12月在我院输血科采集献血者血液样本1298份。取5 mL血样,取管切开,将全血放入试管离心分离血清。采用试管聚苯乙烯试验、试管抗球蛋白试验(AGT)和EMT筛选不规则抗体方法同时检测不同红细胞血型抗体滴度,确定最佳检测方法。结果:通过试管聚苯乙烯试验、试管AGT和EMT同时检测不规则抗体。发现EMT筛选不规则抗体方法可以检测出所有的免疫球蛋白G (IgG)和免疫球蛋白M (IgM)不规则抗体,手工试管AGT结果令人满意,但操作时间长,设备占地面积大。EMT筛选不规则抗体试验测定其对O型Rh (D)红细胞的活性,结果令人满意。此外,与常规试管法相比,EMT筛选不规则抗体方法更具成本效益,检测效率显著提高。结论:EMT筛选不规则抗体法比常规试管法更快、更有效地检测IgG和IgM不规则抗体,检出率更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of the conventional tube and erythrocyte-magnetized technology in titration of red blood cell alloantibodies.

Background: Erythrocyte alloantibodies are mainly produced after immune stimulation, such as blood transfusion, pregnancy, and transplantation, and are the leading causes of severe hemolytic transfusion reactions and difficulty in blood grouping and matching. Therefore, antibody screening is critical to prevent and improve red cell alloantibodies. Routine tube assay is the primary detection method of antibody screening. Recently, erythrocyte-magnetized technology (EMT) has been increasingly used in clinical practice. This study intends to probe the application and efficacy of the conventional tube and EMT in red blood cell alloantibody titration to provide a reference for clinical blood transfusion.

Aim: To investigate the application value of conventional tube and EMT in red blood cell alloantibody titration and enhance the safety of blood transfusion practice.

Methods: A total of 1298 blood samples were harvested from blood donors at the Department of Blood Transfusion of our hospital from March 2021 to December 2022. A 5 mL blood sample was collected in tubing, which was then cut, and the whole blood was put into a test tube for centrifugation to separate the serum. Different red blood cell blood group antibody titers were simultaneously detected using the tube polybrene test, tube antiglobulin test (AGT), and EMT screening irregular antibody methods to determine the best test method.

Results: Simultaneous detection was performed through the tube polybrene test, tube AGT and EMT screening irregular antibodies. It was discovered that the EMT screening irregular antibody method could detect all immunoglobulin G (IgG) and immunoglobulin M (IgM) irregular antibodies, and the results of manual tube AGT were satisfactory, but the operation time was lengthy, and the equipment had a large footprint. The EMT screening irregular antibody assay was also conducted to determine its activity against type O Rh (D) red blood cells, and the outcomes were satisfactory. Furthermore, compared to the conventional tube method, the EMT screening irregular antibody method was more cost-effective and had significantly higher detection efficiency.

Conclusion: With a higher detection rate, the EMT screening irregular antibody method can detect both IgG and IgM irregular antibodies faster and more effectively than the conventional tube method.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Hmo1: A versatile member of the high mobility group box family of chromosomal architecture proteins Hmo1: A versatile member of the high mobility group box family of chromosomal architecture proteins In silico evidence of Remdesivir action in blood coagulation cascade modulation in COVID-19 treatment. Comparison of the conventional tube and erythrocyte-magnetized technology in titration of red blood cell alloantibodies. Molecular genetics of early-onset colorectal cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1