在 55 岁以下患者的初次全髋关节置换术中,传统股骨柄与短的非骨水泥股骨柄的中期疗效对比。

IF 1.3 4区 医学 Q3 ORTHOPEDICS HIP International Pub Date : 2024-01-01 Epub Date: 2023-06-09 DOI:10.1177/11207000231177588
Fernando Diaz-Dilernia, Carlos Lucero, Pablo A Slullitel, Gerardo Zanotti, Fernando Comba, Francisco Piccaluga, Martin Buttaro
{"title":"在 55 岁以下患者的初次全髋关节置换术中,传统股骨柄与短的非骨水泥股骨柄的中期疗效对比。","authors":"Fernando Diaz-Dilernia, Carlos Lucero, Pablo A Slullitel, Gerardo Zanotti, Fernando Comba, Francisco Piccaluga, Martin Buttaro","doi":"10.1177/11207000231177588","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Short stems are designed with a bone preservation philosophy in mind. This study aims to compare the outcomes/complications and survival of a collarless fully hydroxyapatite (HA)-coated conventional tapered stem and a HA-coated partial neck-retaining uncemented short stem in patients ⩽55 years old at medium-term follow-up.</p><p><strong>Methods: </strong>We retrospectively studied 247 uncemented THAs operated between 2010 and 2014, comparing 146 patients treated with the fully HA-coated collarless stem (Group A) with 101 patients treated with a partial neck preserving, HA-coated short stem (Group B). 87 and 62 males were in groups A and B, respectively (<i>p</i> <i>=</i> 0.11). The mean age of the series was 46 years (17-55) (<i>p =</i>0.16). The mean follow-up of groups A and B were 9.9 (7-12) years and 9.7 (7-12) years, respectively (<i>p =</i>0.21).</p><p><strong>Results: </strong>Mean Harris Hip Score improved from 55 to 92 in group A (<i>p <</i>0.001) and from 54 to 95 in group B (<i>p <</i>0.001), without differences between groups. Mean femoral neck length preservation in groups A and B was 13.6 (0-28) mm and 26 (11-38) mm, respectively (<i>p =</i>0.001). 13 (8.9%) and 1 (1%) patients in groups A and B presented postoperative complications, respectively (<i>p =</i>0.008). The conventional stem group had more aseptic loosening (Group A 3.4% vs. Group B 0%, <i>p =</i>0.06) along with more Symptomatic radiolucent lines (Group A 3.4% vs. Group B 0%, <i>p =</i>0.06).</p><p><strong>Conclusions: </strong>Both conventional and short stems showed excellent implant survival rates and functional outcomes at a mean follow-up of 9.8 years. However, complications and radiolucent lines were more frequent with a collarless conventional-length stem. Bone preservation of the femoral neck and diaphysis may be preferred in active young patients.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Medium-term outcomes of conventional versus short uncemented femoral stems for primary total hip arthroplasty in patients younger than 55 years.\",\"authors\":\"Fernando Diaz-Dilernia, Carlos Lucero, Pablo A Slullitel, Gerardo Zanotti, Fernando Comba, Francisco Piccaluga, Martin Buttaro\",\"doi\":\"10.1177/11207000231177588\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Short stems are designed with a bone preservation philosophy in mind. This study aims to compare the outcomes/complications and survival of a collarless fully hydroxyapatite (HA)-coated conventional tapered stem and a HA-coated partial neck-retaining uncemented short stem in patients ⩽55 years old at medium-term follow-up.</p><p><strong>Methods: </strong>We retrospectively studied 247 uncemented THAs operated between 2010 and 2014, comparing 146 patients treated with the fully HA-coated collarless stem (Group A) with 101 patients treated with a partial neck preserving, HA-coated short stem (Group B). 87 and 62 males were in groups A and B, respectively (<i>p</i> <i>=</i> 0.11). The mean age of the series was 46 years (17-55) (<i>p =</i>0.16). The mean follow-up of groups A and B were 9.9 (7-12) years and 9.7 (7-12) years, respectively (<i>p =</i>0.21).</p><p><strong>Results: </strong>Mean Harris Hip Score improved from 55 to 92 in group A (<i>p <</i>0.001) and from 54 to 95 in group B (<i>p <</i>0.001), without differences between groups. Mean femoral neck length preservation in groups A and B was 13.6 (0-28) mm and 26 (11-38) mm, respectively (<i>p =</i>0.001). 13 (8.9%) and 1 (1%) patients in groups A and B presented postoperative complications, respectively (<i>p =</i>0.008). The conventional stem group had more aseptic loosening (Group A 3.4% vs. Group B 0%, <i>p =</i>0.06) along with more Symptomatic radiolucent lines (Group A 3.4% vs. Group B 0%, <i>p =</i>0.06).</p><p><strong>Conclusions: </strong>Both conventional and short stems showed excellent implant survival rates and functional outcomes at a mean follow-up of 9.8 years. However, complications and radiolucent lines were more frequent with a collarless conventional-length stem. Bone preservation of the femoral neck and diaphysis may be preferred in active young patients.</p>\",\"PeriodicalId\":12911,\"journal\":{\"name\":\"HIP International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HIP International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11207000231177588\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000231177588","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景介绍短茎设计时考虑到了骨保存理念。本研究旨在比较55岁以下患者在中期随访时使用无领全羟基磷灰石(HA)涂层传统锥形柄和HA涂层部分颈部保留非骨水泥短柄的结果/并发症和存活率:我们回顾性研究了2010年至2014年期间进行的247例非骨水泥THA手术,比较了146例使用完全HA涂层无领柄治疗的患者(A组)和101例使用部分保留颈部、HA涂层短柄治疗的患者(B组)。A组和B组分别有87名和62名男性(P = 0.11)。该系列患者的平均年龄为46岁(17-55岁)(P =0.16)。A 组和 B 组的平均随访时间分别为 9.9 (7-12) 年和 9.7 (7-12) 年(P =0.21):结果:A组的平均哈里斯髋关节评分从55分提高到92分(P 0.001),B组从54分提高到95分(P 0.001),组间无差异。A 组和 B 组的股骨颈平均保留长度分别为 13.6(0-28)毫米和 26(11-38)毫米(P =0.001)。A组和B组分别有13名(8.9%)和1名(1%)患者出现术后并发症(P =0.008)。传统骨干组的无菌性松动率较高(A组3.4%,B组0%,P =0.06),无症状放射线较多(A组3.4%,B组0%,P =0.06):结论:在平均9.8年的随访中,传统基台和短基台都显示出良好的植入存活率和功能效果。结论:在平均9.8年的随访中,常规和短柄植入体的存活率和功能效果都很好。然而,无领常规长度柄的并发症和放射线更常见。对于活跃的年轻患者,保留股骨颈和骨骺的骨质可能是首选。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Medium-term outcomes of conventional versus short uncemented femoral stems for primary total hip arthroplasty in patients younger than 55 years.

Background: Short stems are designed with a bone preservation philosophy in mind. This study aims to compare the outcomes/complications and survival of a collarless fully hydroxyapatite (HA)-coated conventional tapered stem and a HA-coated partial neck-retaining uncemented short stem in patients ⩽55 years old at medium-term follow-up.

Methods: We retrospectively studied 247 uncemented THAs operated between 2010 and 2014, comparing 146 patients treated with the fully HA-coated collarless stem (Group A) with 101 patients treated with a partial neck preserving, HA-coated short stem (Group B). 87 and 62 males were in groups A and B, respectively (p= 0.11). The mean age of the series was 46 years (17-55) (p =0.16). The mean follow-up of groups A and B were 9.9 (7-12) years and 9.7 (7-12) years, respectively (p =0.21).

Results: Mean Harris Hip Score improved from 55 to 92 in group A (p <0.001) and from 54 to 95 in group B (p <0.001), without differences between groups. Mean femoral neck length preservation in groups A and B was 13.6 (0-28) mm and 26 (11-38) mm, respectively (p =0.001). 13 (8.9%) and 1 (1%) patients in groups A and B presented postoperative complications, respectively (p =0.008). The conventional stem group had more aseptic loosening (Group A 3.4% vs. Group B 0%, p =0.06) along with more Symptomatic radiolucent lines (Group A 3.4% vs. Group B 0%, p =0.06).

Conclusions: Both conventional and short stems showed excellent implant survival rates and functional outcomes at a mean follow-up of 9.8 years. However, complications and radiolucent lines were more frequent with a collarless conventional-length stem. Bone preservation of the femoral neck and diaphysis may be preferred in active young patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
HIP International
HIP International 医学-整形外科
CiteScore
4.20
自引率
0.00%
发文量
70
审稿时长
2 months
期刊介绍: HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice. The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit. HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are: • Biomaterials • Biomechanics • Conservative Hip Surgery • Paediatrics • Primary and Revision Hip Arthroplasty • Traumatology
期刊最新文献
A multicentre prospective assessment of the utility of robotic assisted total hip arthroplasty with virtual range of motion on intraoperative implant positioning. Adverse events associated with robotic-assistance in total hip arthroplasty: an analysis based on the FDA MAUDE database. High incidence of femoroacetabular impingement deformity in bi-column acetabular fractures. No difference in early functional outcome between the direct anterior approach and posterior approach in patients following total hip arthroplasty. Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1